Get complete information related to latest Electrical Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Cable Tenders.
Tender For nit 21 work of replacement of submersible pump sets and accessories of tubewell at various locations under uwss chomu under jen section chomu (urban) under sub div chomu in jurisdiction of executive engineer, phed district division ii, jaipur - 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electricalcables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.2 up to 5.5 kw (7.5 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electricalcables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.4 7.5 kw (10 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electricalcables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.6 9.3 kw (12.5 hp) & head above 120 mtr., 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. the size of cc platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. the panel should have opening of suitable size in front of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt ac supply.2.18.1 above 5 hp and up to 10 hp, 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. t
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , electricalcable lugs (q3)
Tender For electricalcable lugs (q3) , modular piano type domestic fan regulator conforming to is 11037 (q3) , modular piano type domestic electrical sockets isi marked to is 1293 (q2) , modular piano type domestic electrical switches isi marked to is 3854 (q2)
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto
Tender For corrigendum : providing of repair and overhauling service - shifting of electricalcables and switches of blocking bollards, spike barrier and boom barrier; shifting of electricalcables and switches of blocking bollards, spike barrier and boom barrier; yes; buyer premises