Web Analytics Made Easy - StatCounter

Electrical Cabling Tenders

Get complete information related to latest Electrical Cabling Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Cabling Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Cabling Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45519882 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supplying electrical materials and repair maintenance services at. grampanchayat chimbali. - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1-3-3, supplying and e

State Government

CTN :45535656 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For providing and laying wire crates on link road bro road to tubewell and mohalla ex. bdo baldev raj pyt. gurha jagir under permanent restoration (fy 2026-27) (ist call)

State Government

CTN :45535659 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For providing and laying wire crates on link road jadh to panjgrian km 4th to 5th pyt. lehar under permanent restoration (fy 2026-27) (ist call)

Central Government/Public Sector

CTN :45366634 Due date: 22 Jun, 202622 Jun, 2026 25.00 Lacs
Tender For corrigendum : repair to sunken flooring, plumbing with connected items to otm accn in aor of age b/r-ii of ge (east) ferozepur cantt - demolition of un-reinforced cement concrete in any position, complete all as specified and directed., m&l for cement concrete (1:5:10) type e-2 using 40 mm graded stone aggregate as in filling in sunkan slab or as in sub base, mass concrete, complete all as specified and directed., m&l for 15 mm thick rendering over concrete surface of sunken floor in cm 1:3 on wall as well as sunken floor finished even and smooth without using extra cement using wpc complete all as specified and directed.(wpc measured and paid separetely), m&l for water proofing treatment to rcc sunken floor including wall comprising with the following course of treatment/ specifications form bottom to top:-(a) applying evenly a tack coat of industrial bitumen 85/25 @ 1.6 kg per sqm over a coat of bitumen primer @ 0.40 ltr per sqm including preparation of roof surfaces complete all as specified and as directed.(b) app based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.note: (i) laying of app based membranes shall be done by torch on method or as per manufacturers instructions.(ii) a minimum overlap shall be not to be less than 150mm of polymeric membranes and sealed all overlaps and joints as manufacturers instructions.(iii) all ci/pvc traps in sunken slabs to be enclosed with pcc 1:1.5:3(min 15 cm) all round., supply only integral water proofing compound, complete all as specified and directed., taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished fair and even including wpc,preparation of new plastered or unplastered surfaces and applying two coats of cement based paint over a coat of chalk white primer on walls complete all as specified and directed. (wpc measured and paid separately), m&l for preparing old surfaces plastered or unplastered of walls, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coats of cement based paint complete all as specified and directed., m&l for rendering 15 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished fair and smooth without using extra cement complete all as specified including preparation of new surfaces of wall and applying two coats of oil bound distemper on walls including corneces, pillars etc complete all as specified & directed., m&l for preparation of old decorated surface of wall and applying one coat of oil emulsion distemper, complete all as specified and directed., m&l for rendering 5 mm thick on ceiling surfaces in cement mortar (1:3) finished even & smooth without using extra cement including preparation of new plastered or unplastered surfaces and applying two coats of white wash on ceilings, complete all as specified and directed., m&l for preparing old surfaces plastered or unplastered of ceiling, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime wash (white washing), complete all as specified and directed., resecuring or eashing & adjusting, without taking down of shutters of any description of exc. 1 sqm but n.exc. 2 sqm each complete all as specified & directed., taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 square metre each including cut

State Government

CTN :45261763 Due date: 15 Jun, 202615 Jun, 2026 70.00 Lacs
Tender For corrigendum : supply of carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure 8.5 mtr pcc pole , erection of single pole structure 8.5 mtrs pcc pole , erection of tri pole structure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri

State Government

CTN :45261767 Due date: 15 Jun, 202615 Jun, 2026 76.00 Lacs
Tender For corrigendum : supply of stay rod 20x1800 mm, etc material from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr rabbit conductor from esc mnp , carriage of acsr weasel conductor or insulated conductor as provided by department from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x185 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv straight through size 3x185 sq.mm. from esc mnp , carriage of 11 kv vcb for og ctr 200by100by5a 350 mva 1250 amp. from esc mnp , carriage of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. from esc mnp , carriage of g.i. wire 6or8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of l.t. fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr rabbit conductor , laying of acsr weasel conductor or insulated conductor as provided by department , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , mounting of three phase distribution box , erection of double pole structure , erection of single pole structure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line with gaurding angel etc , fencing of distribution transformers , make plinth for 250 kva transformer proper size as per resspo norms , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 11 kv xlpe cable 3x185 sq.mm. , laying of 11 kv xlpe cable 3x300 sq.mm. , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv straight through size 3x185 sq.mm. as per norms. , installation of 11 kv vcb og ctr 200by100by5a 350 mva 1250 amp. , installation of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. , dismentlling of old and damaged cable of different size , received back of distribution transformer after increasing capacity

State Government

CTN :45282107 Due date: 15 Jun, 202615 Jun, 2026 63.00 Lacs
Tender For corrigendum : supply of supply of 11 kv v type cross arm clamp , supply of 3 phase dis. box clamp with nut and bolts , supply of connecting cable , supply of l.t. fuse set protection box , supply of tinned copper fuse wire different size , supply of hdpe pipe , supply of stone pad , supply of holding clamp , supply of ms angle , supply of t-off chhanel , supply of top chhanel 125x65x240 , supply of dropper channel 100x50x2028 mm. , supply of danger board with clamp and nut and bolt , supply of g.i. patti clamp nut and bolts , supply of l.t. tail less unit , supply of copper l-pieace , supply of 11 kv f clamp , supply of suspension clamp , supply of dead end clamp , supply of eye i hook , supply of eye bolts for guarding , supply of j hook , supply of lt clamp , supply of pearcing connector , supply of alluminium lug 120 sq.mm. , supply of alluminium lug 240 sq.mm. , supply of alluminium lug 70 sq.mm. , supply of nut bolts and washers off size , supply of guarding angel , supply of guarding angel clamp , supply of m.s. angel iron 65x65x6 mm. , carriage of 9 m stp pole-sp- 55 galvanised , carriage of 11 m stp pole-sp- 55 galvanised , carriage of 8.5 m pcc pole , carriage of v type cross arm for 11 kv , carriage of 11 kv pin insulator with pin , carriage of disc insulator with fitting t and c 45 kn , carriage of 11 kv fuse set , carriage of 11 kv tpmo with polymer insulator , carriage of complete stay , carriage of distribution transformer 25 kva , carriage of distribution transformer 63 kva , carriage of distribution transformer 100 kva , carriage of distribution transformer 250 kva , carriage of acsr dog conductor , carriage of acsr weasel conductor , carriage of m s earthing rod 20 x2540 mm , carriage of lt al. xlpe cable size 1x240 sq.mm. , carriage of lt pvc cable 1x120 sq.mm. for dtr , carriage of lt pvc armoured cable size 3.5x70 or 35 sq.mm. , carriage of 11 ) /bid number : gem/2026/b/7551524 * /dated: 20-05-2026 & & / bid document 1 / 54 kv xlpe cable 3x185 sq.mm. , carriage of lt ab cable 3x120 sq.mm. , carriage of lt ab cable 3x50 sq.mm. , carriage of lt ab cable 3x95 sq.mm. , carriage of lt pvc armoured cable size 4x25 sq.mm. , carriage of 33 kv xlpe cable 3x300 sq.mm. , carriage of 33 kv indoor or outdoor jointing kit , carriage of 11 kv indoor or outdoor jointing kit , carriage of 33 kv straight through , carriage of 11 kv straight through size 3x185 sq.mm. , carriage of 11 kv vcb , carriage of g.i. wire 6 or 8 swg for guarding , carriage of three phase distribution box , erection of l.t. fuse set protection box , execution of chemical earthing with g.i. patti clamp nut and bolts , execution of pipe earthing with g.i. patti clamp nut and bolts , erection of l.t. tail less unit with all respective material , laying of acsr dog conductor , laying of acsr weasel conductor , laying of lt ab cable 3x120 sq.mm. , laying of lt ab cable 3x50 sq.mm. , laying of lt ab cable 3x95 sq.mm. , mounting of 3 phase distribution box , erection of double pole structure , erection of single pole structure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of distribution transformers , plinth work , installation of transformers 11 or 0.4 kv t or f 25 kva , installation of transformers 11 or 0.4 kv t or f 63 kva , installation of transformers 11 or 0.4 kv t or f 100 kva , installation of transformers 11 or 0.4 kv t or f 250 kva , laying of cable 11 kv xlpe cable 3x185 sq.mm. , laying of cable 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit , installation of 11 kv indoor or outdoor jointing kit , installation of 33 kv straight through , installation of 11 kv straight through , installation of 11 kv vcb , dismentlling of jarjar g.i. wire and weasel conducter , received back of distribution transformer

State Government

CTN :45345707 Due date: 17 Jun, 202617 Jun, 2026 24.00 Lacs
Tender For corrigendum : supply of supply of 11 kv line material , supply of lt line material , safe carriage of 11 kv line material , safe carriage of 8.5 m pcc pole , safe carriage of 11 m stp , erection of 8.5 m pcc single support , erection of 11 m stp single support , erection of 8.5 m pcc double pole , erection of 11 m stp section double pole , dismentalling old weseal conductor , laying acsr weseal conductor , erection of stone pad , erection of barbed wire , erection of f bracket , erection of danger board , erection of pg clamp , erection of allunimum paint , erection of red oxide paint , erection of holding clamp , laying of gi wire 8 swg , laying of gi wire 10 swg , erection of earthing complete , erection of stay set complete , dismentalling of st pole etc , safe carriage of dismantilled material , safe carriage of dismantilled st pole etc , safe carriage of lt line material , safe carriage of lt ab cable , dismentalling of lt ab cable , erection of lt cable , safe carriage of dismantilled lt ab cable

CTN :45512468 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For air cooled ducted 16.5 tr ac unit , air cooled ducted 5 tr ac unit , unloading lifting and shifting of 16.5 tr ducted package ac unit at site , unloading lifting and shifting of 5 tr ducted package ac unit at site , installation n2 pressure testing vacummising and commissioning of 16.5 tr ac , installation n2 pressure testing vacummising and commissioning of 5 tr ac , supply and charging of r 410 gas , supply and inst of floor mounted ms stand fabricated out of ms channel , supply and inst of floor mounted ms stand fabricated out of ms angel , hard copper refrigerant piping between indoor and outdoor units , supply and installation of gss ducting as 24g , supply and installation of gss ducting as 22g , acoustic insulation of plenum initial ducting with 10mm thick armasound , supply and fixing of 13mm thick nitrile rubber al foil faced insulation class i , supply and installation of ai powered jet nozzles with volume control damper , supply and inst of ai powered return air grills without volume control dampers , supply and installation of gi opposed blade duct dampers, qty 1.5 sqmtr , supply and fixing of canvas connection , supply and laying of 32mm dia pvc drain piping , electrical cabling 6 c x 1.5 sqmm cu flexible , electrical cabling 3 c x 1.5 sqmm cu flexible , electrical cabling 1 sqmm cu flexible double earthing * /bid number : gem/2026/b/7581741 + /dated: 11-06-2026 ' ' / bid document 1 / 24

CTN :45527844 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply of 1.5 ton ac , 2.0 ton ac , supply and fixing of ms stand , supply and laying of cable , supply and installation of electric water cooler , supply and installation of deep freezer , supply and installation of refrigerator , supply and installation of desert cooler , supply and fixed mcb 20 amp , supply and fixed sub main wiring , supply and fixed copper wire , supply and fixed pvc drain pipe
 Loading, Please wait...

Connect us via What's Up