Get complete information related to latest Electrical Conduit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Conduit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Conduit Tenders.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.
Tender For supply of micro lithium cell 3v of digital multimeter , head light relay of scorpio , wiper blade eicher canter , fuse 30 amps common , horn push pull switch common , wiper blade force traveller , push pull switch common , water valve 2 inch brass , tail lifgt assy eicher canter , fuse 15 amps common , wiper blade mahinda scorpio , jubliee clip fuel pipe common different sizes , wiper blade swaraj mazda , brake light cover assy rhs swaraj mazda , handle inner door eicher canter and swaraj mazda , gasket gasket making seat , door regulator handle eicher canter and swaraj mazda , bulb twin filamet common , indicator assy front tata , wiper blade tata , tail light assy right tata , tail lifght assy tata , indicator assy front swaraj mazda , fuel pipe line both side 19mm end qty trhee one side 19 other side 17mm end qty two , connector female electrical , connector male electrical , radiator hose set eicher swaraj mazda and tata , shellock anabond tube , bulb 12 v 21 w , bulb 12v 21 and 6w , bulb 12 v 3 w , bulb 12 v 6w , fuse 20 amps common , eyelet female electrical , looming tape , lt wire electrical wire , electricalconduit , eyelets electrical , bolt with nut qty 10 10mm qty 10 12mm qty 10 16mm , fog light assy , cable tie , side indicator lifgt lh eicher canter and swaraz mazda , side indicator lifgt rh eicher canter and swaraz mazda , fuse 10 common , split pin small to large size minimum 2 qty per size
Tender For supply of gi metal back box 08 module , gi metal back box 12 module , gi metal back box 02 module , tresa plate with frame 08 module , tresa plate with frame12 module , tresa plate with frame 02 module , 6 amps modular 5 pin socket , 15 amps modular 5 pin socket , 6 amps modular indicators , 16 amps modular switch , 20 amps modular dp mcb , 1.5 inch pvc junction box , 1.5 inch pvc electricalconduit pipe , 1.5 inch l bend , 1.5 inch t bend , 1.5 inch casing and caping , metal clamp for conduit pipe , steel concrete nails 1.5 inch , flexible conduit pipe , insulatioin tape , 6 amp modular swtich , anchor pvc 5 amp s i s combination , 15 amp s i s combination box , 0-10 amps ac ammeter analog , 0-10 amps ac ammeter digital , 0-10 hp single phase preventer , 0-1000v meggar meco , 0-20 amps overload relay , 0-300 v ac voltmeter analog , 0-300 v ac voltmeter digital , 0-5 amps ac ammeter analog , 0-5 amps ac ammeter digital , 0-500v meggar meco , 0-600 v ac voltmeter analog , 0-600 v ac voltmeter digital * /bid number : gem/2026/b/7646786 + /dated: 10-06-2026 ' ' / bid document 1 / 28
Tender For bid to ras supply of installation and set up of ncn connectivity at arogya complex d d -optical fibre 48 f unarmoured ribbon type , optical fiber digging or clamping or laying in pipe , pigtail , splacing of fiber , supply and installation of otb 12 f , supply and installation of 20 a mcb switch socket , supply and installation of 48 port switch with 1gb sfp ncn compatible , 9 u rack with dual power supply ncn compatible , 2 kva ups with rack and 06 nos 12v 18 ah batteries with each ups , jack panel , 2 ft patch cord , 5 mtr lc-sc fibre , 10 mtr lc-sc fibre , supply and installation of cat 6 cable , supply and installation of 2 port i o , electricalconduit 32 mm , 32 mm capping and casing of ibd work , earthing strip , chemical earthing , earthing termination box , earthing cable 1c x 4 sqmm , supply and installation and commissioning of 3cx4 sqmm power cable , supply and installation and commissioning of 3cx2. 5 sqmm power cable , integration and commissioning of access switches with existing cucm ) /bid number: gem/2026/b/7233281 * /dated: 05-03-2026 & & / bid document1 / 27