Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For corrigendum : repair/ replacement and maintenance of ht switchgear, vcb, rmu, lbs and transformer, cables, earthing and other connected items at gandhinagar military station
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For tender for carrying out composite work (furnishing electrical and ac low side works) of existing branch office at wagholi, gat no 740/1 & 2, shiva palace co op hsg society, wagholi pune 412207contractors empanelled under interior & furnishing work may tie-up with any empanelled electricalcontractor of the bank by entering into mou with them and their bids shall be considered for further evaluation.
Tender For corrigendum : empanelment of electricalcontractors for a period of two years for supply of material erection testing commissioning of augmentation of existing 33 kv sub stations lines construction of new 33 kv lines augmentation of existing 33 kv lines and
Tender For auction sale of depot ferrous scrap - junk (low qualtiy) 98090800 m.s. junk / kachara (low quality): scrap released consisting mainly of low-grade, assorted and mixed mild steel junk (kachara) generated from various railway activities including pressed and empty paint/oil drums,fire extinguish with or without powder,grease manual pump,fan blade,tubelight patti,small paint drum (may be tin ), damaged filters and filter frames, ducts, ms sheet, grills, sliding channels, scrap panels, broken housings, earthing wire,galvanized iron sheet, cabinets and almirah parts, lockers, racks, benches, trays, boxes, covers, frames, brackets, ladders, pipes, rods, bars, wire mesh, mesh guards, grills, scrap sheets, angles, channels, booms, posts, discarded machine parts, miscellaneous fabricated structures, signal and electrical cabinets, dp/mldb boards, relay/telecom racks in scrap condition, cable trays, junction/location boxes, display boards, indicator housings, transformer fittings, tu/dac/aws covers, brake related scrap, air filter assemblies, pantograph related scrap parts, trolleys, damaged hand tools, crane and track machine scrap parts, hydraulic components in scrap condition, racks, ballast tools, scrap furniture,ci pipe , bed and seat frames, cupboards, doors, bins, chains, nuts, bolts and mixed hardware; material is highly rusted, bent, broken, corroded and mixed with mud, dust, grease, paint or oil residues and environmental deposits; all items are unserviceable, obsolete and beyond economical repair (ber); minor non-ferrous, rubber, plastic, insulation, rexine or wooden attachments may be present without segregation; this lot is low quality junk kachara, not identifiable item-wise and not fit for railway use; no claim shall be entertained regarding quantity, composition, quality or recoverability,sold strictly on %u201cas is where is%u201d basis; loading by purchaser, mechanized loading permitted, mud, rust, debris and all remains shall form part of the lot; custodian: dms/scrap/pardi
Tender For tender for selection of licensed electricalcontractors for execution of 1kw lt electricity connection works from pole to gram panchayat (gp) bhavans in connection with implementation of amended bharat-net program (abp) in karnataka state
Tender For rate contract for supply of electrical spares and minor store/hardware items, as given in the detailed boq, from govt approved, reputed, experienced, competent n financially sound electricalcontractors/firms/suppliers/jvs/ executors/oems - part: (a) 132kv transmission lines (material ), al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr zebra conductor (make: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided)., p g clamp for acsr panther conductor as per relevant is/iec amended upto date and of reputed/standard make, p g clamp for acsr moose conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct clamp (universal take off) for panther conductor with ct terminals suitable for 132kv/33kv cts as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of panther conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic breaker pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv breakers of sf 6 type-abb,cgl, siemens, bhel/vcb type- s&s, gec alsthom, bhel, abb, siemens, megawin etc as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct pad clamp (universal take off) for twin acsr zebra conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv ct as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic twin isolator pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin acsr zebra conductor with conductor spacing 300mm and isolator pad clamp terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv isolator as per relevant is/iec amended upto date and of reputed/standard make, bimetallic ct pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bimetallic breaker pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and isolator terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor with pad terminals suitable for 132kv /33kv isolator of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for single panther conductor of reputed/standard make, t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr -panther-acsr panther conductor of reputed/standard make, t-