Tender For restoring and repair of main water supply line and ferrule connection delhi jal board line to music faculty and jubilee hall hostel and replacement of water metre at faculty of management, university of delhi - -restoring and repair of main water supply line and ferrule connection delhi jal board line to music faculty and jubilee hall hostel and replacement of water metre at faculty of management, university of delhi
Tender For supply of rpl no 10 c c - suppl and fixing of 1 exhaust fan for kitchen room with 15amp socket , supply and fixing of electric wiring in chamber no 02 , supply and fixing of 06 15amp combination board , supply and fixing of 05 led bulb 9 watt , supply and fixing of 01 switch board 10inch x 12inch , supply and fixing of 10 switch 5amp , supply and fixing of 06 socket 5 amp , supply and fixing of 02 security light , replacement of existing 02 ms icon pipe bend of toilet outlet of master cabin toilet of sbs as per existing specification , repair of sea water pipe line of 2hp motor , replacement of existing tapet cover gas kit of main engine of both sides as per existing specification , repair of radiator fan vibrating defect of sbs of main engine , replacement of existing 02 iron battery box as per existing specification including all changes , supply and fixing of 02 exhaust fan of aux engine room , repair of leakage defect of pt pump of sbs and replacement of existing fuel line as per exiting specification
Tender For supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distributionboard , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For supply of repair of epson head and pump assy , repair of canon printer power supply and main board , repair of hp printer logical card and taflon pressure roller , repair of epson printer head and services , repair of epson printer wasting pad and sensor , repair of canon printer head waste pad
Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For corrigendum : special repair to ug water sump of old pump house rcc oh tank at arf filter house and replacement of lt panel board oh to ug cable and allied work at main water supply installation under age em and age br ii of ge bengdubi
Tender For repair replacement of internal wiring point wiring and sub main wiring including connected items at zone b otm and md accn at ins rajali under ge m arakkonam - taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed., material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- make of cable : plaza/polycab/finolex/ havells, one light/ fan/ exhaust fan/ buzzer point controlled by one switch., one 3 pin socket outlet 6 amps, independent board with cables 1.5 sqmm size., one 3 pin socket outlet 6 amps,same board with cables 1.5 sqmm size., one light point controlled by two 2- way switches, with cable 1.5 sqmm size., all as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size.make :- polycab/finolex/plaza/havells, material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor drawn into pvc conduit and casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- make for pvc casing & caping: sudhakar / avon plast /plaza , make for copper cable: finolex/polycab / plaza., one light point controlled by one switch., one 3 pin socket outlet 6 amps, indipendent board with cables 1.5 sqmm size., all as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size. make :- polycab/finolex/plaza, m&l for sub main wiring for phase and neutral with pvc frls insulated unsheathed multi stranded along with earth wire frls pvc insulted copper conductor, single core cable in and including surface/concealed /pvc conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. make for copper cables: finolex/polycab / plaza/ havells. make of pvc conduit: sudhakar/finolex/avon plast., 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire, 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire, 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire, 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire, 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire, 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire, taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed., supply and fixing in repair of gi metal flush box suitable for mounting moduler plate of following modules:-, 1 or 2 module, 3 module, 4 module, 6 module, 8 module, 12 module, supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for following modules:-, c
Tender For providing and fitting of al cable along with accessories and realignment of diesel generator set wiring and allied works in the divisional office. - providing & fitting of al cable in the division office. the job involves providing/fitting of angle board on the wall, with the help of hammer and chisels. providing and fitting of automatic change over switch one, switch disconnector 01 no s. al cable capacity 3.5 core 50 mm sq 20 mtrs in length from dg set to change over switch. along with pvc pipe clumps. providing and fitting of 16 mm sq. multistrand copper wire 10 mtr. in length from main switch to automatic change over to fuse box. checking of connections, repairs/replacement to wiring wherever damaged. providing and fitting of three tube lights, switch, fans two nos, extension wire for wifi sets. testing on load complete job. the job further also includes repair/replacement of damaged wooden doors 03 no s size (81 43 ) & 01 no s size (74 43 ) , frames, shutters, panels, replacement of unserviceable wooden members, fixing of hinges, handles, tower bolts, locks, glass panes, and all allied fittings. the work also includes surface preparation, polishing/painting, and finishing to ensure proper functionality and durability., the work includes repair and installation of 01 no s aluminium paneling size (36 24 ), including fixing of aluminium sheets/panels, frames, fasteners, and all allied accessories as required. the scope also covers repair/replacement of wooden paneling size (84 84 ), including fixing of wooden boards, framing members, polishing/finishing, and all associated carpentry works. the job includes cost of material & labour charges complete job.
Tender For bid to ras supply of s and f of ring main system for wss - supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supply and fix valve reflux with by pass arrangement 100mm 4 inches dia , supply and fix foot valve confirming to is 4038 100mm 4 inches dia , supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia , supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia , supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core , supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc , supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc , supply install test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc , supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in ) /bid number : gem/2026/b/7514655 * /dated: 08-05-2026 & & / bid document 1 / 21 & & ' ' /item category cast iron water supply mains , excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc , returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge , removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc , boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special , di or ci special such as tee bend collar tail piece and other fitting as required , earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode , demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness , m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness , m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc , m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame