Get complete information related to latest Electrical Fittings Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Fittings Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Fittings Tenders.
Tender For repair/maint of unserviceable internal wiring electricalfittings, ceiling/ exhaust fans/ summer appliances, day to day electrical complaints at d, e, f type officers qtrs, scientist hostel, dlomi and swimming pool at drdo township kbagh hyderabad
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For supply of supply of conventional lightning arrestors , supply of insulated multi stranded 75 sq.mm. copper wire with copper lugs , supply of frangible fiber-reinforced plastic frp poles , construction of concrete base for erecting frp poles , construction of conventional earthing pits , supply of copper plate , supply of copper strip , supply of pvc pipe for earth pits , supply of earthing salt , supply of charcoal granules , construction of earth pit inspection chamber , supply of metal signage board , brazing points , installation work
Tender For supply of combined 5 pin 15 amp , bell switch 5 amp , pvc switch and socket combine with board 15 by 16 amp , pvc switch and socket combine with board 5 by 6 amp , distilled water , combination plier , cutting plier , screw driver set , ceiling led light , 2 pole mcb 10 ampcomma 220 volt , 2 pole mcb 16 ampcomma 220 volt , 2 pole mcb 32 ampcomma 220 volt , 2 pole mcb 64 ampcomma 220 volt , 0point5 hp water pump , car air pressure pump , 16 amp switch , 16 amp socket , mcb 2 pole 20 amp , 4 into 7 pvc board gangbox , 12 into 12 pvc board gangbox , 4 into 4 pvc board gangbox , 6 amp socket , main switch 63 amp , cable 2 core roll of 91 mtr 6 sqmm aluminium , change over switch 400 amp 3 phase 4 pole , 200 amp cut off fuse , 200 amp 3 pole mcb , mcb 63 ampcomma 220 volt , cable 2 core roll of 91 mtr 10 sqmm aluminium , main switch 100 amp , xlpe three core 50 sq mm aluminium unarmoured power cable 1 point 1 kv , cable 2 core roll of 91 mtr 16 sqmm aluminium , earthing set meter tester , earthing wire single core 1point5 sq mm , line tester , bulb holder , red indicator light for electric board , cable 2 core roll of 91 mtr 2point5 sqmm , kit kat fuse box 3 pole , xlpe two core 50 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe four core 25 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe two core 25 sq mm aluminium unarmoured power cable 1 point 1 kv , xlpe two core 16 sq mm aluminium unarmoured power cable 1point1 kv , 100 amp 415 volt busbar chamber board with 100a four pole isolator protection , mccb 415 volt 3 phase 100 amp , mcb box 8 way , gi tubular pole 100 mm dia length 5 mtr thickness 4 mm with baseplate 250mm x 250mm as per is 2713 part 1 and part 3 , aluminium lug 50 mm , aluminium lug 10 mm , aluminium lug 25 mm , gi nut and bolt size m 10 length 50 mm full thread , charcoal , salt , earthing plate 2 feet into 2 feet into 8 mm , gi wire 6 mm , winding wire , cable tie lock belt 6 feet feet , main switch box 4 pole 3 phase 200 amp , exhaust fan 9 feet feet 30 watt , screw size 1 feet feet , bed switch size 6 amp 220 volt , batton holder 06 amp 220 volt , pendant holder 06 amp 220 volt , lighting conductor rod , hydrometer for specific gravity , drill machine set battery , change over switch 32 amp single phase 2 pole , kit kat fuse switch gears , extension board of 02 capacity , ampere meter , double core wire 8 sq mm , double core wire 16 sq mm , double core wire 25 sq mm , digital clamp meter , dc test lamp automatic circuit tester , multistrand electrical wire 2 sq mm pvc single core , tulu pump 1 to 1 point 5 hp , pvc gang box 4 into 2 , pvc gang box 2 into 2 5 pin socket 5 amp, switch 5 amp, 3 pin plug 15 amp, 3 pin plug 05 amp, modular switch board (4 switch, 1 socket), modular switch board (6 switch, 1 socket), modular switch board (8 switch, 2 socket), 1 switch + 1 socket smart switch board , 4 switch + 1 socket smart switch board , 6 switch + 2 socket smart switch board , 8 switch + 2 socket smart switch board , cable four core 10 sq mm , cable 2 core roll of 91 mtr 10 sqmm, cable 2 core roll of 91 mtr 6 sqmm , multistrand electrical wire 6.0 sq mm pvc single core, multistrand electrical wire 4.0 sq mm pvc single core, multistrand electrical wire 2.5 sq mm pvc single core, multistrand electrical wire 1.5 sq mm pvc single core, multistrand electrical wire 1.0 sq mm pvc single core, multistrand electrical wire 0.75 sq mm pvc single core, casing and caping 20 mm (length of 3 mtr), casing and caping 25 mm (length of 3 mtr), led bulb 20/24 watt, //bid details 2 / 94
Tender For supply of plastic shredder manual feeding, 6 to 8 kg per hr , weighing scale 200 kg capacity , screw type bending and heating equipment 10 to 12 kg per hr with motor, gearbox and control panel , hydraulic press , die for 150 x 150 x 40 mm paver block , die for 200 x 100 x 40 mm paver block , wet cyclone scrubber with ducting and blower , containerized setup 20x8 with electricalfittings , commissioning of machines including logistics , consultancy fee
Tender For procurement of electricalfittings for cps at srhp sikidiri, procurement of electrical spares items for ph-ii at srhp sikidiri, supply of cctv with its accessories including installation, testing & commissioning at various sites at srhp sikidiri.
Tender For bid to ras supply of fabrication and construction of copper plate earthing details of electrodes and earth pit at hpt tv site gurez, jammu and kashmir. , interconnecting earth electrodes with providing, fabrication and fixing of 50mmx3mm copper strip at hpt tv site gurez, jammu and kashmir. , copper strip laying for extension of earthing system up to the xtr hall, ups and lt panel and terminating in bus bar by digging the soil and placing the copper strip along the trenches at hpt tv gurez , providing of 375x38x6mm copper bus bar with insulators and steel nut bolts and the fixing of 375x38x6mm copper bus bar is to be done to terminate the different earthing system at hpt tv gurez, jandk , providing and fixing of nomenclature sign marker for earth pits at hpt tv site gurez, jammu and kashmir. ) /bid number : gem/2026/b/7514498 * /dated: 13-05-2026 & & / bid document 1 / 18
Tender For auction sale of land - bapatla district - s.ps.r nellore dist, kavali sub-register office, jaladanki mandal,annavaram grama panchayat area, nellore urban development authority, annavaram village, sy.no:404, assessement 484 of house site. bounded by: east house of bodi chinnaiah west house of bodi venkateswarlu north: road south site of aluri narasa reddy with in these boundaries an extent of 16 ankanamas of 36 sq.ft. or 132 sq.yds of site, in it 380 sq.ft, of rcc roofed house, fixed doors, door frames, windows, ceiling materials, one feet site, security deposit, electricalfittings, wiring, latrine, bathroom, four side compound walls, hand pump etc, and including all its easements rights therein.