Web Analytics Made Easy - StatCounter

Electrical Item Tenders

Get complete information related to latest Electrical Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Item Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations/Associations/Others

CTN :45723864 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of electrical materials for rahata municipal council for fy 2026-27 - electrical item list, 5 w led ( / ), 5 w led ( / ), 15w led ( / ), 18w led ( / ), 20w led ( / ), led 12 w ( / ), led 18 w ( / ), 25 w l.e.d ( / ), w l.e.d ( / ), 45 w l.e.d ( / ), 100 w l.e.d ( / ), 15 w ( , ), 18 w ( , ), 20 w ( , ), 30 w ( , ), 36w ( , ), 100 w l.e.d ( / ), 150w led / , 200w led / , led 5 w ( / ), led w ( / ), w ( / ), v ( / ), v ( / ), v ah (exide/luminous), , w ( / ), led 5w ( / ), led 10w ( / ), led 15w ( / ), led 18w ( / ), led 20w ( / ), 1/18 ( ), 3/20 ( ), 1 sq mm (90 .) polycab, 1.5 sq mm (90 .) polycab, 2.5 sq mm (90 .) polycab, 4 sq mm ( ), 6 sq mm ( ), 16 sq mm ( ), 36/40 ( ), 35 sq mm, 25 sq mm, 35 mm, 55 mm, 4 sq mm , 6 sq mm , sq mm , 10 sq mm, 16 sq mm, 20 sq mm, 1.5 sq mm polycab, 2.5 sq mm polycab, 4 sq mm polycab, . . ( )220 v, p.v.c . steel grip tape, 30 a ( ), 60 a ( ), 100 a ( ), 30 a ( ), 60 a ( ), 100 a ( ), 100 a . . . ( ), ( ), ( ), 1.1/4 1x1 ( ), 8 ( ), 16 ( ), ( / ), ( / ), ( / ), 63 a . . , 8 ( ) , 8 , 10 , 12 , , , , , 75/8 box, 35/8 box, , 6 a (anchor/v guard), 16 a (anchor/v guard), 6a (anchor/v guard), 16a (anchor/v guard), 4 (anchor/v guard), 6 (anchor/v guard), 12 (anchor/v guard), 16 (anchor/v guard), 18 (anchor/v guard), modi company, , , isi mark, isi mark, isi mark, 200 amp , 5 a, 10 a, 16 a, (dewalt/ dongcheng), (dewalt/ dongcheng), 10 sq mm, 15 sq mm, 20 sq mm, (dewalt/ dongcheng), , , , , isi mark, (dewalt/ dongcheng), (dewalt/ dongcheng), , 20mm, 25 mm, 35 mm, 50 mm, 90 mm, 120 mm, , mcb 10 a (polycab /anchor), mcb 20 a (polycab /anchor), mcb 30 a (polycab /anchor), mcb 40 a (polycab /anchor), mcb 400w (polycab /anchor), 100 a ( ), 63 a ( ), , , , , 4 mm, 6 mm, 8 mm, 10 mm, 12 mm, 14 mm, 16 mm, 20 mm, isi mark, 2 isi mark, 2 isi mark, 9 isi mark, / , , , anchor, 4x6, 8x6, 8x12, , , , isi mark, , , , , , 4 4 anchor, 2 2 anchor, 10 mm, 14 mm, 16mm, 10 mm, 14 mm, 16mm, , , , frp ( ) , frp ( ) , , , anchor, anchor, , , , , , 1 we, 2 we, 3 we, 20mm, , , , 2.5, 3.15, 4, 6, 8, 25, 36, 50, , 2 , 3 , 4 , 5 , , , , (lt), (lt), contactor (lt), contactor (lt), lcb switch 32 amp (lt), lcb switch 63 amp (lt), elcb switch 32 amp (lt), elcb switch 63 amp (lt), mccb switch 32 amp (lt), mccb switch 63 amp (lt), mccb switch 20 amp (lt), mcb switch 2 pole 20 amp (polycab/anchor), mcb switch 3 pole 20 amp (polycab/anchor), mcb switch 4 pole 20 amp (polycab/anchor), mcb switch 2 pole 32 amp (polycab/anchor), mcb switch 3 pole 32 amp (polycab/anchor), mcb switch 4 pole 32 amp (polycab/anchor), mcb switch 2 pole 40 amp (polycab/anchor), mcb switch 3 pole 40 amp (polycab/anchor), mcb switch 4 pole 40 amp (polycab/anchor), pendent holder (anchor), batan holder (anchor), angel holder(anchor),

State Government

CTN :45734784 Due date: 09 Jul, 202609 Jul, 2026 41.17 Lacs
Tender For providing 200 kva t/f, 11 mtr. long solar high mast in s/c parking and 12.5 mtr. long high mast at water works in hsvp sector-1 nmt kosli (including 6 yeras dlp of t/f 5 year dlp of led solar lights and 3 year dlp of all other electrical item and

Central Government/Public Sector

CTN :45478509 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of electrical items - copper conductor cable , electrical switches , electrical sockets , fan regulator , electrical material , led lamps , exhaust fans , tool kit

State Government

CTN :45724106 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For tender for electrical items/ aluminum cable, copper wire

State Government

CTN :45732687 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For nonond block: sampla panchayat: nonand dist.: rohtak annual maintenance work for water supply. - electrical items - starter, repair of 40 hp oil immersed starter incl. finger, gutka and labour charges etc.

corporations/Associations/Others

CTN :45728426 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For auction sale of electrical items

corporations/Associations/Others

CTN :45728448 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For auction sale of miscellaneous electrical items

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
 Loading, Please wait...

Connect us via What's Up