Tender For 8125/sar-t-54/2025-26 provn of ac points and allied works in smqs and special repair to electric wiring and allied works at officers mess, l/in accn for sncos and airmen at 1afsb dehradun under ge (af) sarsawa
Tender For corrigendum : repair/maint of internal wiring in otm accn/offices, mh incl repair/replacement of old unsv fittings and fixtures, solar heaters, geysers, earthing, summer appliances, meters incl other electric fitments at pangode mil stn under ge (army) trivandrum
Tender For overhauling & assembly of s-4 engine, maintenance of clutch assembly, complete brake assembly, hydraulic system, gear assembly, electric wiring & accessories fittings and other repair works as per scope of work for forklifts with m&p no. hp-1039, hp-1046, hp-1047 & hp-1048 of c&w workshop, eastern railway, liluah through works contract on open tender basis.
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; installation work of drill machine with wiring and electric power point the rates inclusive wastage, labour and other necessary fitting completed electrici..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; installation work of grinding machine with wiring and electric power point. the rates inclusive wastage, labour and other necessary fitting completed (elec..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; providing and fixing aluminium cable 10 mm 4 core and power conecctive pole to 100 amp 3phase main switch completed.(electrician lab); service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; making a foundation l type (size east 439"x23"x26", west 216"x23"x26" south 420"x23"x26") brick work in ration 1:3 and cement and core sand with plaster wo..,repair, maintenanc
Tender For bid to ras tender for supply of m and l for point wiring complete with 1 5 sqmm nominal area pvc insulated multi stranded frls copper conductor cable unsheathed in and including pvc conduit with all fittings medium grade isi marked and pvc insulated frls copper conductor cable of size 1 5 sq mm as earth wire connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate with cover complete all as specified and as directed by engr in charge the works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate make of cable finolex polycab havells , one light fan point controlled by one switch , one switch socket outlet 3 pin 5 amp on the independent board , one switch socket outlet 3 pin 5 amp on same board , all as per item no 1 here in-before but with 2 single core pvc insulated frls and sheathed copper conductor of size 2 5 sqmm in and including pvc conduit isi marked including cutting chiseling and grouting concealed pvc conduit pipe tee elbow and bend etc and with all connecting accessories with 2 5 sqmm pvc insulated frls copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 amp socket outlet on the independent board using 2 5 sqmm copper cable incl pvc insulated copeer conductor 1 5 sqmm as continued earth wire make of cable finolex polycab havells , all as per item no 1 here in before but with 2 single core pvc insulated frls and sheathed copper conductor of size 4 sqmm in and including pvc conduit isi marked including cutting chiseling and grouting concealed pvc conduit pipe tee elbow and bend etc and with all connecting accessories with 4 sqmm pvc insulated frls copper conductor as earth wire and connecting to common earth dolly for 20 amps socket outlet on the independent board make finolex polycab havells , s and f modular switch 1 way 16 amps 1 module complete all as specified and as directed by engineer in charge , s and f modular socket outlet 6a 16a 2 3 pin combined 2 module complete all as specified and as directed by engineer in charge , s and f modular switch 1 way 6 amps 1 module complete all as specified and as directed by engineer in charge , s and f modular socket outlet 6a 2 3 pin combined 2 module complete all as specified and as directed by engineer in charge , supply and fixing led luminaire 600 mm x 600 mm 35 36 watt 220 v ac recessed type with high efficiency pmma diffuser soft glare free light complete with driver holders and led lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed , supply installation commissioning and testing invertor type bee 5 star rating air cooled split unit air conditioner electric driven single phase of capacity 1 5 tr eco friendly refrigerant hi wall split units indoor and outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with 5 star rated auto restart facility 100 present copper tube and condenser including excess copper tubing if required beyond the lenght 7 5 mtrs supplied with ac unit and pvc conduit of 15mm dia not exceeding 2 5 mtr long for water drain including drilling hole through drill machine and making good to disturbed surface with cement mortar ratio 1 3 to match the existing surface complete all as specified and directed by engineer in charge make voltas blue star hitachi daikin or equivalent out of make specified in list of make , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of plus minus 2 5 persent suitable for 1 5 ton ac operation complete all as specified and directed , supply and fixing single pole and neutral enclosure with a two pin and earth plug and soc
Tender For bid to ras corrigendum : supply of sitc of hi wall split ac , s and f stabilizer , m and l sub main wiring , s and f ss combine , fixing of geyser , s and f mcb , m and l sub main , m and l gi tube , cutting , s and f bib tap , m and l stop valve , electric water heater - geyser (v2) as per is 2082:2018 (latest) (q3)
Tender For corrigendum : certain repair to building security light electric distribution boxes mccb mcb sub main and point wiring at various location and comprehensive maint of fire fighting system software control panel fire alarm system smoke detectors at mh mhow under ge mis
Tender For supply of m l for wiring for circuits sub main wiring with frlsh pvc sheathed 2 x 4 sqmm,s f electric water heater storage type steel body with copper inner tank,s f switch socket combination 2 in 1 3 pin 5 amp and 15 amp flush type,s f pcrd plug cap 20 amp 220volts 50 hz,s f bib taps 15 mm dia cast copper alloy, with crutch or butterfly handle,s f stop valve angle cock 15mm dia cast copper alloy with crutch or butterfly,s f galvanized steel tubes medium grade of size 15mm dia and incl fixing,s f 6 to 32 amps mcb single pole 240 v 10 ka c series