Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of electricalmeasuringinstruments and tools for emd3 dhuvaran gbps. - digital megger 1000 volts, 0- 500/1000/2000 mohm ranges, motwane make 5kv insulation tester, model: 5kpi., digital ma clamp on meter, ac/dc digital clamp on meter, digital multimeter., digital micro ohm meter model, impact wrench power/battery operated, hand grinder machine., tools bag (taad patri type, thick cloth) with 3 to 4 pockets for artisian tools having size 16" x 4" x 10"approximate
Tender For corrigendum : work of thermal scanning of transmission lines through high resolution infrared auto focus camara under electricity transmission circle, gorakhpur
Tender For thermal scanning and submission of thermal imaging report in hard copy of 400 kv, 220kv and 132 kv transmission lines under e.t.d, unnao & raebareli
Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : providing of calibration services - electrical, work of calibration of electricalmeasuringinstruments as per iso requirement for gandhinagar tps; as per atc-179; as per atc-179; buyer premises (onsite)