Tender For bid to ras corrigendum : supply of led luminaire (recessed luminaire) (v3) conforming to is 10322 (part 5/section 2),single core 4 sqmm frlsh pvc insulated copper cable,curtain rod stainless steel cp 18 or 20 mm dia,cp handle 75mm long with steel screw,ppr pipe 110mm,sodium hypochloride 6 to7 percetage in liquid form,asian paint syn enamelled black of 1 ltr,ppr pipe 75mm,non contact ac voltage with led flash light and audible beeper voltage range 200 to 1000vac 50 or 60 hz battery operated,digital cable fault locator or tracer for lt cable battery operated with featyres a transmitter and receiver,digital trms ac or dc high performance clamp meter with led display for measuring dc or ac current upto 1000 ac ordc dc or ac voltage upto 600 volts resistance capacitance frequency,clamp on ground or earth reistance tester measurement range 0 ohm to 1500 ohm and range of current 0ma to 35ma with storage and alarm,battery analyserr wiht built in priner suitable for 12 or 24 v lcd display for measuring battery voltage battery capacity internal resistan
Tender For corrigendum : supply of programmable power supply 400 watts , multiple output dc power supply 375 watts , safety ohm meter , multimeter , bench top digital multimeter , oscilloscope probe-300 mhz, 10 is to 1 ratio
Tender For corrigendum : supply of miscellaneous control and instrumentation items for btps, obra. - lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze/ metal bowl filter element, lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze filter element, stub for steam line and w.o. outlet bfp (as per sample), thermowell for steam / water line and w.o. (as per sample), thermocouple k-type duplex with head l-400mm od-19mm, k- type thermocouple od-6mm l-320mm bsp (m), k- type without head connation thermocouple for boiler/ turbine metal temperature measurement l-15mtr, od-6mm, rtd (prt-100*ohm*) thermocouple type along with thermowell head connection 320mm, od-6mm duplex bsp, rtd (prt-100*ohm*) capsule type thermocouple along with thermowell head connection l-20mm, od-4mm, (20x10) & od-3mm (5 nos) duplex type m&f adjust, k- type thermocouple od-6mm l-400mm bsp (m), pa fan temp. switches 0-120 deg. c1. dial size: 150 mm normal dia, white back ground, black marking2. range: 0 120 c3. case: weather proof to ip: 65 as per is:13947, die cast aluminium, bezel ring4. stem: 10 mm dia in ss 316, total stem length-200 mm5. connection: 3/4" npt(m) gland table in ss3046. capillary: ss 304 covered, 10 meter long solid drawn7. accuracy: 1% of fsd for indication & 2% of fsd for switching8. over range: 120 % of fsd9. window: acrylic10. contacts: 2spst contact, both normal op to close on rise of temperature rated 30 va, 240 v ac., temperature switch: fd fan stem length 175mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.tech. specification: -1. dial size 100 mm nominal dia, white back ground, black marking.2. range 0 120 deg.c.3. case weather proof p: 65 as per is: 2147, die cast aluminium with screwed aluminium, bezel ring.4. stem 10 mm dia in ss 316, total stem length-175 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered + pvc coating, 03 meter long.7. accuracy of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10.contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac., temperature switch stem size 300mm for id fan temperature switch: stem length 300 mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification: -1. dial size 100 mm normal dia, white back ground, black mar 2. range 0 120 deg. c.3. case weather proof to ip: 65 as per is: 2147, die cast aluminium with screwed, bezel ring.4. stem 10 mm dia in ss 316, total stem length-300 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered with coating, 03 meter long.7. accuracy 1% of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10. contacts 1 spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, temperature switch stem size 150mm temperature switch: stem length 150 mm, 0 200 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification:1. dial size 150 mm normal dia, white back ground, black marking2. rang 200 deg. c3. case weatherproof to ip: 65 as per is:2147, die cast aluminium with screwed, bezel ring4. stem 10 mm dia in ss 316, total stem length-150 mm5. connection 1/2" npt(m) gland adjustable in ss3046. capillary ss 304 covered with pvc coating, 03 met ng7. accuracy 1% of fsd for indication 2% of fsd for switching8. over range 120 % of fsd9. window acrylic10. contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, digital ind 4 digit dual channel 138x32mm, digital ind 4 digit single channel 138x32mm, 3 nos.)
Tender For corrigendum : supply of ntc sensor 5.0 k +/- 2% ohm @ 25 degree centigrade, operating temperature - 40 degree centigrade to 140 degree centigrade with two meter teflon wire as per amphenol part no. nka502c1r1 / ndp502c1r1 (or) vishay part no. ntcle305e4502sba (
Tender For tender for supply of maintenance testing and servicing of numerical relays and calibration of meters : : - bucholz relay prd oti wti master relay make alstom or areva or ge , micom p111 make areva , micom p141 make areva , micom p211 make areva , p3u30 make schneider electric ln 110 v ac , numerical non-directional current protection relay csenex-i 100 make c&s , overcurrent and earth fault relay idmt relays range 0.5 amps to 2 amps , overcurrent and earth fault relay idmt relays range 0.1 amps to 0.4 amps , calibration of 1phase energy meter 1 phase 2 wire static watt hour meter , calibration of 3 phase energy meter 3 phase 4 wire make l and t , calibration of 3 phase energy meter conzerv em1000 make schnider electric , calibration of 3 phase energy meter em6400ng make schneider , 500v to 1000v megger calibration hand held rotary type and digital type , earth megger model det 10 range 0 to 10 ohm make shanthi instruments
Tender For supply of digital display clamp meter, specific [digital display clamp meter, specification ac range 0-600 a & resolution 0.1-1a + accuracy 1.5% to 2.5% +/-5 digit(50-500 hz) dc range 0-1000 a & resolution is 0.1-1 a + accuracy 1.5% +/- 5 digit (40a-600a). ac/dc voltage range is 0-600v+accuracy+/- 1% to 1.5%. resistance range 0-400 (ohm) frequncy20-400 hz with backlight. safety iec 61010 cat-iii 600 v. make: fluke, megger & yokogava or similar. ]
Tender For corrigendum : supply of description: digital micro ohm meter with following features: - (i) 1 micro ohm resolution of 10a test current(ii) 4 terminal kelvin measurement with 4 wire leads. (iii) batteryoperated with rechargeable battery and inbuilt charge unit. (iv) accuracy: + or - 0.25%, (v) make/brand: motwane model no.lr 2065 or similar. (vi) resistance range (ohm): 10 micro ohm to 20 kiloohm (vii) resolution: 0.1 micro ohm [ warranty period: 30 months after the date of delivery ]