Get complete information related to latest Electrical Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Plug Tenders.
Tender For corrigendum : custom bid for services - agency for electrical testing jobs at various sub-stations and associated locations of iocl guwahati refinery, tender no-9010c25b16-a. scope of work for service line#10 electrical troubleshooting, scheme modifications & reliability improvement jobs manpower to be deputed at site as per clause 1.3 and following jobs/ activities shall be required to be carried out as per requirement and instruction of site engineer/ engineer-in- charge of iocl. the activities mentioned below gives a tentative idea of the jobs to be carried out. however, the jobs that are not mentioned here but which come under the scope of testing related jobs shall also be included as per the instructions/ directions of site engineer/ engineer-in-charge as part of the job with no additional financial implication on iocl. all equipment, instruments, wires, connectors etc. required for carrying out the job shall be in the scope of the party. b. scope of work for service line#20 to & fro transportation charges of additional electrical equipment/ instrument as per site requirement to & fro transportation charges of additional equipment/ instrument (auto/ manual transformer winding resistance meter/ circuit breaker analyzer kit for breaker close, open, close-open timing/ secondary current injection testing kit (make: omicron, freja, megger, scope)/ hv ac kit / hv dc kit suitable for 132kv system) required at site as decided by eic including all charges, arrangements, requirements to be done to make the instrument available at site as per requirement per equipment/ instrument per trip. if the equipment gets defective during the use at site or could not be used at site due to unsuitable personnel or unsuitable equipment/ instrument due to any reason, then the to and fro transportation charge shall not be paid. c. scope of service for service line#30 hire charges per week (07 working days) for auto/ manual transformer winding resistance meter as per site requirement hire charges per week (07 days) for providing and utilizing the auto/ manual transformer winding resistance meter of reputed make required at site for site testing related activities with the equipment/ instrument. d. scope of service for service line#40 - hire charges per week (07 working days) for circuit breaker analyzer kit for breaker close, open, close-open timing as per site requirement hire charges per week (07 days) for providing and utilizing the circuit breaker analyzer kit for breaker close, open, close-open timing of reputed make required at site for site testing related activities with the equipment/ instrument. e. scope of service for service line#50 hire charges per week (07 working days) for secondary current injection testing kit upto 150a (make: omicron, freja) as per site requirement hire charges per week (07 days) for providing and utilizing the secondary current injection testing kit upto 150a (make: omicron, freja, megger, scope) of reputed make at site for site testing activities with the equipment/ instrument. f. scope of service for service line#60 hire charges per week (07 working days) for hv ac kit suitable for 132kv system as per site requirement hire charges per week (07 days) for providing and utilizing the hv ac kit of reputed make at site for site testing activities with the equipment/ instrument. g.scope of service for service line#60 hire charges per week (07 working days) for hv dc kit suitable for 132kv system as per site requirement hire charges per week (07 days) for providing and utilizing the hv dc kit upto 132kv of reputed make at site for site testing activities with the equipment/ instrument..
Tender For purchase of electrical items - make: havels/siemens/l&t/bch/schneider :- miniature circuit breaker, 32 amps, 2 pole mcb without metal enclosure, for lighting circuits, 230v ac, type b or c tripping, is/iec 60898 standard, overload and short circuit protection., 16 amps, 1 pole mcb without metal enclosure, for lighting circuits, 230v ac, type b or c tripping, is/iec 60898 standard, overload and short circuit protection., 63 amps, 3 pole mcb with metal enclosure, for power load circuits, 415v ac, type c or d tripping, is/iec 60898 standard, overload and short circuit protection., on/off push button element (1 no + 1 nc), - l & t make:, push button with 1 normally open (no) and 1 normally closed (nc) contact, rated for 230v ac, ip65 protection, robust construction, suitable for control circuits. colour: red for off, green for on., double pole toggle switch, 16 amps:, 16 amps, double pole toggle switch, 230v ac, robust construction, suitable for switching power circuits, with positive locking mechanism, rated for industrial use, ip20 protection., ammeter:, 96 x 96 mm analog ammeter, measuring range suitable for ct ratio 100/5, 230v ac, high accuracy, clear scale markings, robust construction, and suitable for industrial applications., crc liquid spray (multi-purpose, corrosion-resistant, moisture-displacing, lubricating, and protective spray) with high dielectric strength, rapid penetration, and long-lasting rust prevention, packed in 500 ml aerosol cans., 2 core 1.5 sqmm pvc insulated flexible copper conductor cable, rated for 300/500v, is 694 compliant, 1 core, 2.5 sqmm., pc insulated, flexible copper conductor cable, rated for 300/500v is 694 compliant, suitable for industrial power load applications.
Tender For supply of electrical general items - heavy duty switch disconnector fuse unit, tpn rating 250 amp. suitable , din fuse-link, make siemens , heavy duty switch disconnector fuse unit, tpn rating 125 amp. suitable , din fuse-link, make siemens , heavy duty switch disconnector fuse unit, tpn rating 125 amp. suitable , din fuse-link, with ss incloser big size make siemens , under voltage relay supply voltage 220-240, 50 hz type yu-1sda038312r1, make abb , closing coil supply voltage 220-240, 50 hz type yc-1sda038302r1, make abb , mccb 125 a 3pole , 50ka, make abb , motor circuit breaker rating 10a type: gv2me14, term/mag 6-10 a rocker make: schneider electric , power contactor 3pole coil voltage 110v ac, type: a185-30, make : abb , power contactor kit for abb make contactor, a185-30, , power contactor kit for abb make contactor, a145-30, , aux. contact for (abb make contactor a185-30) type cal18-11, 1no+1nc, make abb , power contactor 3tf47, 3pole, coil voltage 230v, 50hz, with 2no + 2nc aux contact, make siemens , power contactor 3tf34, 3pole, coil voltage 230v, 50hz, , make siemens , power contactor 3tf33, 3pole, coil voltage 230v, 50hz, make siemens , power contactor 3tf32, 3pole, coil voltage 230v, 50hz, with 1no aux contact, make siemens , ca5 x-01 (aux. contact), make abb , ca5 x-10 (aux. contact), make abb , 2no+1nc aux contact for (mnx9 contactor) , 3tx4010-2a-1no (aux. contact), make siemens , 3tx4001-2a-1no (aux. contact), make siemens , ca5-40e (aux. contact) make abb , ca5-22e (aux. contact) make abb , compact motor protection relay model: mm10 ct sec 5a aux. 230v ac make l&t , mcb schneider/abb make, 10 ka, , 63 a, 4 pole , 63 a, 3 pole , 63 a, 2 pole , 32 a, 4 pole , 32 a, 3 pole , 32 a, 2 pole , 25 a, 1 pole , a, 1 pole , 25a, 2 pole , 25 a, 4 pole , 63a, 4pole, 10 ka mcb, make: legrand/schneider/abb , with 1no+nc aux. contact , change over relay contact rating 3a. coil voltage 230 v 50hz , with base, make schneider/abb , change over relay contact rating 3a. coil voltage 24 vdc , with base, make schneider/abb , rotary handle operating mechanism for (630amp sfu, type os630d03-3, make abb) , hrc fuse link, type 3na, make siemens , 125 a, size 00 , 250 a, size 1 , hrc fuse link, type tia, make siemens 125 a, , kit-kat sm type (fuse holder), 125a , overload relay, make l & t, range: , 6-10a (mk1) , 9-14a (mk1) , 14-23 (mn5) , 20-33 (mn5) , 9-15 (mn2) , overload relay, make siemens, range: 25-40 a (3ua58) , abb make overload relay 18-25a , tc make overload relay 9- 18 a , terminal block, make connectwell/ wago/elmax 16 mm2 , terminal block (nut bolt type), make connectwell/ wago/elmax , 35mm2 , 95mm2 , 120mm2 , heavy duty copper lug (ring type) make dowells/havells/jaycee, , 16 mm2 , 50 mm2 , heavy duty copper thimble long barrel make dowells/havells, size: , 35 mm2 , 70 mm2 , 95 mm2 , heavy duty aluminium thimble long barrel, make dowells/havells/jaycee, size: , 35 mm2 , 50 mm2 , 70 mm2 , 120 mm2 , heavy duty copper thimble l shape, make dowells/havells/jaycee size: , 35mm2 , 50 mm2 , 70 mm2 , 95 mm2 , heavy duty copper ferrule, make dowells/havells/jaycee, size: , 35 mm2 , heavy duty aluminium ferrule, make dowells/havells/jaycee, size: , 70 mm , heavy duty copper lug (ring type) size: 10mm2 (3d10-10) od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 16mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 25mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 35mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 50mm2 od 22mm, id 12mm lump-sum , single compression cable gland ss, make dowells/havells/jaycee/mic, size: , 16 mm2 , 19 mm2 , 22 mm2 , pvc cable gland make any standard size , 19 mm2 , 22 mm2 , double compression cable gland ss, make dowells/havells/jaycee/mic, size: , 25 mm2 , 28 mm2 , 38 mm2 , 45 mm2 , 50 mm2 , analog ct operated meter size 96x96 mm ae make , 150/5 , 100/5 , 30a direct meter , digital voltmeter meter, mode alp
Tender For bid to ras corrigendum : supply of non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , led batten (q2) , self ballasted led lamps for general lighting services (v2) conforming to is 16102 (q2) , led luminaire for road and street lights (v2) conforming to is 10322 (part 5 / section 3) (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , electricalplugs (v2) isi marked to is 1293 (q2) , elecric bells and accessories as per is 2268 (q3)
Tender For work of scheduled testing (33 kv vcb, 11 kv incoming/outgoing feeder breaker and power converter) for smooth operation of 12 nos. 33/11 kv substations in the jurisdiction of electricity distribution division mitauli under the jurisdiction of electrical testing division lakhimpur.
Tender For work related to protection on 05 mva transformer installed at 33/11 kv substation nikuniya in the jurisdiction of electricity distribution division nighasan under the jurisdiction of electrical testing division lakhimpur, such as repair and overhauling of breaker and current transformer (ct).