Get complete information related to latest Electrical Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40899068 Due date: 15 Jul, 202515 Jul, 2025 1.97 Crore
Tender For tender for the supply of interventional radiology list . 1 - vascular plug 14 mm (igot 2025), vascular plug 22 mm (igot 2025), vascular plug 10 mm (igot 2025), vascular plug 16 mm (igot 2025), tips stent 10mm uncovered (igot 2025), tips stent 10 mm covered (igot 2025), tips stent 8 mm uncovered (igot 2025), tips stent 8 mm covered (igot 2025), support catheter (igot 2025), sems uncoverd 5mm x 40mm (igot 2025), sems uncoverd 6mm x 40mm (igot 2025), sems uncoverd 16mm x 80mm (igot 2025), sems uncoverd 16mm x 60mm (igot 2025), sems uncoverd 14mm x 80mm (igot 2025), sems uncoverd 14mm x 60mm (igot 2025), sems uncoverd 10mm x 80mm (igot 2025), sems uncoverd 10mm x 100mm (igot 2025), sems uncoverd 8mm x 80mm (igot 2025), sems uncoverd 8mm x 100mm (igot 2025), sems coverd 10 mm x 100 mm (igot 2025), sems coverd 10 mm x 80 mm (igot 2025), sems coverd 8 mm x 100mm (igot 2025), sems coverd 8 mm x 80 mm (igot 2025), sems coverd 6mm x 60mm (igot 2025), sems coverd 6 mm x 40 mm (igot 2025), retrievable ivc filter - suitable for jugular or femoral delivery (igot 2025), ravi catheter-mg1,mg2 (igot 2025), progreat microcatheter 1.7 fr/1.9fr -130 cm (igot 2025), progreat micro catheter 1.9 / 2.8 (igot 2025), progreat micro catheter 2.7 / 2.9 (igot 2025), progreat micro catheter 2.4 / 2.9 (igot 2025), long guiding sheath 45,65,90 cm (igot 2025), ivc stent - large diameter stent (igot 2025), hepatic vein stent 5 x 40mm (igot 2025), hepatic vein stent 6 x 40mm (igot 2025), guidewire straight tip 0.038x260cm (igot 2025), guidewire straight tip 0.038x150cm (igot 2025), guidewire straight tip 0.032 x260cm (igot 2025), guidewire straight tip 0.032 x150cm (igot 2025), guidewire straight tip 0.035x150cm (igot 2025), guidewire straight tip 0.035x260cm (igot 2025), guide wire curved tip 0.038x260cm (igot 2025), guide wire curved tip 0.038x150cm (igot 2025), guide wire curved tip 0.035x260cm (igot 2025), guide wire curved tip 0.035x150cm (igot 2025), guide wire curved tip 0.032x260cm (igot 2025), guide wire curved tip 0.032x150cm (igot 2025), glidecath 85 cm vertebral 4 fr (igot 2025), glidecath 85 cm yashiro 5fr (igot 2025), glidecath 85 cm yashiro 4fr (igot 2025), glidecath 85 cm 6fr (igot 2025), glidecath 85 cm 4fr (igot 2025), glidecath 85 cm mpa 6fr (igot 2025), glidecath 85 cm mpa 4fr (igot 2025), glidecath 85 cm sim 2 4fr (igot 2025), glidecath 85 cm sim 1 4fr (igot 2025), glidecath 85 cm c2 4f (igot 2025), glidecath 85 cm 4fr c1 (igot 2025), glidecath 65 cm vertebral 4 fr (igot 2025), glidecath 65 cm yashiro 5fr (igot 2025), glidecath 65 cm yashiro 4fr (igot 2025), glidecath 65 cm 6fr (igot 2025), glidecath 65 cm 4fr (igot 2025), glidecath 65 cm mpa 6fr (igot 2025), glidecath 65 cm mpa 4fr (igot 2025), glidecath 65 cm sim 2 4fr (igot 2025), glidecath 65 cm sim 1 4fr (igot 2025), glidecath 65 cm c2 4f (igot 2025), glidecath 65 cm 4fr c1 (igot 2025), glidecath 100 cm vertebral 4 fr (igot 2025), glidecath 100 cm yashiro 5fr (igot 2025), glidecath 100 cm yashiro 4fr (igot 2025), glidecath 100 cm 6fr (igot 2025), glidecath 100 cm 4fr (igot 2025), glidecath 100 cm mpa 6fr (igot 2025), glidecath 100 cm mpa 4fr (igot 2025), glidecath 100 cm sim 2 4fr (igot 2025), glidecath 100 cm sim 1 4fr (igot 2025), glidecath 100 cm c2 4f (igot 2025), glidecath 100 cm 4fr c1 (igot 2025), diagnostic catheter-all shapes ,all sizes (igot 2025), covered stent 8mm (igot 2025), covered stent 9mm (igot 2025), covera plus vascular covered stent 6 mm (igot 2025), covera plus vascular covered stent 8 mm (igot 2025), covera plus vascular covered stent 7 mm (igot 2025), cobra catheter (igot 2025), amplatz gudie wire 0.035x145 (igot 2025), amplatz extra stiff guide wire (igot 2025), amplatz stiff guide wire 260cm (igot 2025), amplatz stiff guide wire 150 cm (igot 2025), accustick (igot 2025)

Central Government / Public Sector

CTN :40404451 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For corrigendum : supply of plug top make sudhir switchgear

Central Government / Public Sector

CTN :40331761 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For corrigendum : procurement of m/s. flexpro electricals pvt. ltd. make plug top at iocl, paradip refinery

Central Government/Public Sector

CTN :40917599 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For supply of gland for 100 mm lubricated taper plug valve as per rdso drg no.wd-93066-s-9 alt-02 or latest. note:- material and specification as per drawing. [ warranty period: 30 month s after the date of delivery ]

State Government

CTN :40906123 Due date: 03 Jul, 202503 Jul, 2025 NA
Tender For quotation for p.t. switch 5 amp , p.t. socket 5 amp , p.t. switch 15 amp , p.t. socket 15 amp , copper wire 2.5 sq mm , tape roll , rawl plug 1.5" , pvc casing capping 20mm , pvc casing capping 25mm , gypsum screw 1.5" , wooden screw 35x8 , machine screw 1" , machine screw 1.50" , machine screw 2" , telephone giti

Central Government/Public Sector

CTN :40917201 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of shock safe portable residual current device (prcd) plug top ,03 pin plug, ratted c urrent 16 amp, ratted voltage 240-260 volt 50 hz ac supply, 30 ma with power indicator, built in reset an d test buttons with suitable wire hole , confirming to is:-1293. supply make:- havells, l&t, bajaj, anchor. ( detailed specification as per annexure-a attached) [ warranty period: 30 months after the date of delive ry ]

Central Government/Public Sector

CTN :40904456 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply of leather washer for drain plug of auxiliary reservoir & brake cylinder as per rdso drg. no. wd-92051-s-01, alt-04, item no. 09, & drg. no. w d-92051-s-14, alt-03 or latest. specn.02-abr-02 [appendix-c ]

State Government

CTN :40910678 Due date: 08 Jul, 202508 Jul, 2025 2.45 Lacs
Tender For providing special repair additional alternation to e.i additional plug points in court rooms and in main building of hp high court shimla.

State Government

CTN :40863730 Due date: 07 Jul, 202507 Jul, 2025 14.16 Lacs
Tender For construction of sub centre bhogoga district kathua (electrical part). - wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, with modular switch, modular plate, suitable gi box earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required (group-a), wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire, 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 16 sq. mm + 1 x 6 sq. mm earth wire, 4 x 6 sq. mm + 2 x 6 sq. mm earth wire, 4 x 10 sq. mm + 2 x 6 sq. mm earth wire, 4 x 16 sq. mm + 2 x 6 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor single core cable in the existing surface/recessed steel/pvc conduit as required., 1 x 1.5 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 3 pin 5/6 a socket outlet, 15/16 a switch, 6 pin 15/16 a socket outlet, supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required, supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 a modular socket outlet and 2 nos. 5/6 a modular switch, connections etc. as required. (for light plugs to be used in non residential buildings)., supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, "c"curve including connections, painting etc. as required., supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required., 1 or 2 module (75mm x 75mm), 3 module (100mm x 75mm), 4 module (125mm x 75mm), 6 module (200mm x 75mm), 8 module (125mm x125mm), 12 module ( 200mm x 150mm), supplying & fixing of following way single pole and netural, sheet steel, mcb distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required., 6 way (double door), 16 way (double door), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/ rccb /isolator), 6 way ( 4+18), (double door), 8 way (4+24), (double door), supplying and fixing following rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole 6/10/16/32 amp, single pole and neutral 32 amp, single pole and neutral 63 amp,

State Government

CTN :40914632 Due date: 14 Jul, 202514 Jul, 2025 1.18 Lacs
Tender For installation of power outlet for use of different bio medical equipment for middle row beds in ward 7, 1st floor ipd building, m. r. bangur hospital, kolkata, south 24 pgs.____installation of plug sockets in medicine store, cabin fan in ward 3, bu i