Tender For repair and maintenance of existing power transformer installed at 33 kv receiving sub-station 11 kv family qtrs substation mt substation under ftr hq bsf kashmir
Tender For repair maintenance of various electrical and mechanical services of meity building lodhi road new delhi sh replacement of wornout mccb of substation panel at meity buildingsubwork/packages:replacement of wornout mccb of substation panel at meity building
Tender For maintenance of electrical installation & fans in all residential and non-residential building, o/m of e&m equipments including repair and maintenance of pumpsets, substation equipments, dg sets and oh lines at svp npa, shivarampally, hyderabad - operation of 33 kv substation, o&m of 11 kv substation, iei & fans, street lights, pumpsets, dg sets, fire alarm, firefighting equipment during the year 2025-2026. sh: supply, installation, testing & commissioning of lt cable from outdoor panel to demonstration area including outdoor panel, earthing at ibrahimpatnam of svp npa, hyderabad.
Tender For maintenance of electrical installation and fans including compound light , repair maintenance of motor pump set, dg set, lifts substation equipments, wet riser, fire alarm at cisf complex em bye pass kasba kolkata during 2025-26(sh: comprehnsive maintenance of ac machine installed at cisf hq kasba)
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; furniture, substation, electrical system or installation; service provider
Tender For corrigendum : supply of call base repair of ems at telephone bhavan - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For repair and maintenance (amc) of the 22kv ht lines (new feeder-i and old feeder-ii) from the 4.5 mw bap kafnu power house to nathpa substation for 120 days (from 15.06.2025 to 15.10.2025
Tender For day to day repair, maintenance and operation by providing high manpower for elect. installation, substation, lift, hvac, dg, fire fighting etc. round the clock at institute bldg. its annex, substation bldg. and hostel bldg. for the period of 2 years
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - sub-station; substation; service provider