Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For procurement of spares for booster pump for sgtpp - procurement of procurement of spares for booster pump for sgtpp., rotor assy. booster pump-fa1b75 for mdbfp of 500 mw , (balanced condition), set contain one shaft, one impeller, impeller neck ring-02 nos, thrust collar, coupling key, pump drg. no- ( drg. no-hy-dg-373-139-a017 moc-shaft-bs-en-10250-4, impeller-bs-en-10213-2, impeller wear ring-bs-en-10213-2, approximate dimension- impeller od-753 mm, impeller width from neck to neck-246, impeller neck od-300 mm, neck id-265 mm, neck width-45 mm, shaft dia at impeller position-84.85 mm, no of vains-06. approximate shaft length-1725 mm, shaft run-out should be within 0.05 mm. for mdbfp , direction of rotation-anti clowise viewed from non-drive end. rotor assembly should be in balanced condition. balancing document should be submitted during delivery. all give dimensions are approximate & actual dimensions must be at per give drawing no. ), impeller for booster pump-fa1b75, for booster pump of 500 mw. , part no-2 , pump drg. no-hy-dg-373-139-a017, moc- bs en 10213-2 ( in balanced condition. balancing document should be submitted during delivery. moc-impeller-bs-en-10213-2, approximate dimension- impeller od-753 mm, impeller width from neck to neck-246, impeller neck od-300 mm, neck id-265 mm, neck width-45 mm, shaft dia at impeller position-84.85 mm, no of vains-06. all give dimensions are approximate & actual dimensions must be at per given drawing no. ), shaft for booster pump-fa1b75 for booster pump of 500 mw. , part no-5 , pump drg. no-hy-dg-373-139-a017, moc-bs en 10250-4 or equivalent ( shaft run-out should be within 0.05 mm. moc-shaft-bs-en-10250-4, approximate shaft length-1725 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. ), impeller nut, booster pump-fa1b75 for booster pump of 500 mw , part no-13, pump drg. no-hy-dg-373-139-a017, nut thrust collar for booster pump-fa1b75 , pump drg. no-hy-dg-373-139-a017, casing wearing ring, f-m/cd-bp-fa1b75 for booster pump ( moc-fv 520 b (13% cr. steel). approximate dimension od-340 mm, id-320 mm, width-45 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. ), wearing ring,impeller,fa1b75 for booster pump fa1b75 ( moc-bs-en-10213-2, approximate dimension od-320 mm, id-300.20 mm, width-45 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. )
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For corrigendum : tender for supply of dg set spares - sealing ring push , o ring delivery tube , seal o ring tc , belt v ribbed , hose pipe , hose plain , hose plain cummins 6bt 125 kva , leak of pipe , seal oil , hose for air cleaner hf494 , seal oil , gasket cylinder head cover , hose rubber , hose rubber , hose rubeer ring joint , hose for breather pipe
Tender For bid to ras corrigendum : supply of 11 kv 750 kva silent dg set , fuel storage ( bulk oil tank) minimum 7.5 kl , mandatory spares and special tools , erection & commissioning of dg set
Tender For corrigendum : supply of 20 kva dg set - supply and installation of 20 kva dg set , transportation sea freight loading and unloading the dg set upto keating point lighthosue , supply and installation of of armoured cable 2 core 25 sqmm , supply and installation of earthing , supply and installation of copper strip , laying of cable and dg set installation , supply and installation of amf panel , consumable of spares for 02 years