Get complete information related to latest Electricity Poles Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electricity Poles Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electricity Poles Tenders.
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr
Tender For corrigendum : provide & fixing of of new street light galvanized octagonal pole on indoor stadium, basketball ground and other area in mc limit gobindgarh
Tender For item supply for chain link fencing, rcc pole and barbed wire - 2026-27 . . . . . . . , galvanized steel chain link fencemesh line wire galvanized steel wire of 3.15 mm diameterfabric size 100x100 mmheight 150 cmline wire 2 numbers of line wire of 4.00 mm diameterstandard- conforming to is-2721-2003, withup to date amendments., rcc fencing poles hight 2.0 mtype straightlenght 2.00 mdimensions bottom 10x10 cm square, top 8x8 cm squarecement concretc mix cement, sand and metal ratio 1:2:4, with 12.5 nominal size coarse aggreate. sand used should be free from clay and salt, concrete mix shall be conforming to grade m-15 of is: 456:2000reinforcement 4 round vertical bars of 6 mm diameter. 11 no of stirrups of 6mm diameter round ms bare 20 cm centre to center.hooks- 5 no. bottom hook should be provided 60 cm above the bottom of the pole. second at 82.5 cm, third hook at 112.5 cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom.manufacturing- in order to ensure desiredcompressive strength, rcc fencing poles should be compacted with the help of platform vibrators. surface should be uniform and free from voids. the concrete cover over the reinforcement should not be less than 1.5 cm, galvanised steel barbed wireline wire- galvanised steel wire of 2.5 mmdiameterpoint wire- galvanised steel wire of 2.5 mmdiameterbarbs distance between two barbs 75 mm, thebarbs shall have four points and shall be formedby twisting two point wires each two turns.tightly around both the line wires makingaltogether four complete turns.standard conforming to is-278-2009
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, rampur maniharan sre in view of the kanwar yatra
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, baliyakhedi sre in view of the kanwar yatra
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, nakur sre in view of the kanwar yatra
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, rampur maniharan sre in view of the kanwar yatra
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, baliyakhedi sre in view of the kanwar yatra
Tender For installation of insulation sheets on electricitypoles along the kanwar route, line re-sagging, and other related works within the jurisdiction of the electricity distribution division, baliyakhedi sre in view of the kanwar yatra
Tender For maint of road side lighting works and miscellaneous electrical items under ge n akhnoor. - labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of t&p (i.e. axe, rope & ladder etc.) complete all as specified and directed., dismantling and taking down street light fittings/post top lantern/down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to mes store and refixing after repair on required location complete all as directed.note: accessories or components needed for replacement shall be measured and paid separately under appropriate items., repairing of unserviceable led street light any make/model of 90 100 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., repairing of unserviceable led street light any make/model of 60 72 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., pvc conduit medium grade of size 15 mm bore including fittings, isi marked, fixing with pcc pole/steel tubular pole/garden lights/gate lights for wiring connection from pole box to light fitting and supporting with 03 nos gi strip clamp, nut & bolt, complete all as specified and directed., replacement of pvc insulated pvc sheathed stranded copper conductor cable 2.5 sqmm twin core complete all as specified and directed., pvc insulation tape of width 18 mm, thickness 0.125 mm, length 25 mtr, isi marked, for proper insulation of joints in wire where required or directed., replacement of aluminium pvc service wire 2 core 6 sqmm flat roll of 90 mtr, superior quality, complete all as specified and directed., disconnecting & dismantling of damaged/unserviceable cable of any type/make and supply & laying in repair/replacement of cable xlpe insulated, screened pvc bedded, galvanized steel strip or wire armoured electric power cables (heavy duty), 1100 volts grade with stranded aluminium conductor using lugs/ferrules at both ends of cable and testing complete all as directed for following sizes:, 10 sqmm 4 crore, 16 sqmm 4 crore, 25 sqmm 3.5 crore, 35 sqmm 3.5 crore, note for item no. 17 & 18: excavation & earth work, sand cushioning, bricks protection & gi pipe where required shall be measured and paid separately., excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr depth, getting out for electric cable complete in any type of soil complete all as specified and directed., removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed., returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed., supply and laying sub class b bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed., sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable) complete all as specified and directed., replacement of 40 mm gi tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/as garden post including 2 nos mild steel fi clamps 35 3 mm size to support pipe with pole complete all as specified and directed., boring under road horizontally of size 40/50 mm bore using gi pipe for passing of cable in road/path in hard/soft/loose soil complete all as specified and directed., applying two coats of aluminium paint over a coat of red oxide on steel tubular po