Get complete information related to latest Electrics Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrics Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrics Equipment Tenders.
Tender For corrigendum : estimate for installation additional 1x63 kva dtr at village karmodiya under kharwai dc o n m div raisen - back filling of poles with boulders., bi-metallic clamps suitable for 12mm dia stud and 80sqmm aaac, bi-metallic clamps distribution transformers bushing, l.t. distribution box with isolator on incoming with hrc fuse for 63 kva dtr (200 amp. isolator & 6 sp of 60 amp.), three phase static energy meters 20-80 amps.with l.s. & tod facility with box, single phase service connection box (deep drwan metal service connection boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector-, three phase service connection box(deep drwan metal service connection boxes ) with one incoming up to 35 mm2 and 4 no outgoing up to 16 mm2 with insulated multiple outgoing connector-, anti climbing devices ( barbed wire 2.24 mm dia, 14 swg), stay wire 7/3.15 mm.(7/10 swg), g.i.pipe 40 mm dia c grade type, earthing coil of 115 turns of 50 mm.dia and 2.5 mtr. lead of 4.0 mm g.i wire, galvanized nut & bolt with washer, earthing for pcc pole 4.00 mm-8 swg g.i wire- 0.8 kg, per pole, m.s.nuts with bolts, lt a.b cable tension clamps (galvanized), lt a b cable suspension clamps (galvanized), clamps for neutral for ab cable, piercing connector type-i for single/three phase (main 16-50 sqmm tap-off 16-50 sqmm), piercing connector type-ii (main 16-50 sqmm tap-off 16-50 sqmm), back clamp for 140 kg pcc pole ms flat 50x6 mm, clamp for 140 kg pcc pole ms flat 50x6 mm, stay set complete without stay wire 16 mm. (painted), danger boards enamelled 11 kv, shackle insulators 90x75 mm., stay insulators 90x65mm, 11 kv pin insulator polymer composit (5 kn), 11 kv(45kn) composite polymer disc insulators, red oxide paint, aluminium paint, concreting of stay (16 mm / 12 mm) @ 0.2 cmt. per stay, complete jumpering of dtr, concreting of structures & foundation (1:3:6), g.i. strip 25x3 mm1, stone block/pre cast block for base pedding(450x450x75mm), bentonite compound powder, gst on material @ 18 %, labour charges including gst @ 18%, transportation charges including gst @ 5%
Tender For corrigendum : supply of 25 kva, 11/0.433 kv, aluminium wound eel-1 (is:1180-1:20144 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box against tn2026
Tender For corrigendum : supply of 40 kva, 11/0.433 kv, aluminium wound eel-1 (is:1180-1:20144 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box against tn2025
Tender For repair of transformer 400 kva outdoor type at af stn memaura : : - disconnecting of hv or lv cable from transformer 400 kva 11or 0point433 kv at site and loading and unloading of transformer at both side s or s a of age i af memaura and repair work premises hiring of crane and transportation charges to workshop from agei af memaura complete all as specified and directedpoint make vishal transformers switchgears pvt ltd sm nopoint 1843089tr04 01 each job , taking down and dismantlingopening up unserviceable transformer step down outdoor type 110point433 kv capacity 400 kva including lifting of core taking out unserviceable burnt winding after dismantling core stampings and draining of transformer oil and storing in a suitable container desludging and cleaning thoroughly rewinding and reinsulating of transformer as per the requirement maintaining existing specificationsize including reassembling core stampings lowering wound core within transformer outer cell and refilling transformer oil after sludge removal of dielectric strength 50 kv at least replacement of silica gel of breather reassembling testing for satisfactory performance and installation and commissioning in the existing position complete all as directedpoint note materials required for winding and insulation shall be measured and paid separately as supply only 01 each job , m l for changing of old burnt copper coil by new dpc copper coils with complete including insulation material of distribution transformer of capacity 400 kva complete all as specified and directedpoint 107 kg , dismantling of unserviceable lt bushing of transformer of capacity 400 kva and supply and fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 02 each set , dismantling of unserviceable 11 kv ht bushing of transformer of capacity 400 kva and supply fix new bushing including brass stud nuts washers and rubber bush complete all as directed by the engineerinchargepoint 01 each set , supply and pour new transformer oil in replacement of approved quality dielectric strength not less than 50 kv isi marked for filling in transformer for topping up complete all as specified and directedpoint 370 ltrs , schedule of credit for old us items will be the property of contractor
Tender For corrigendum : for the work of replacement of old and damaged lt bushing rod including oil seal/gaskets etc. (250 to 1000 kva transformer) under 11 kv and lt line- north, meerut.
Tender For corrigendum : supply of 16 kva 11/0.433 kv aluminium wound eel1 (is1180-1-2014 plus 4 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box
Tender For corrigendum : supply of 25 kva 11/0.433 kv aluminium wound eel1 (is1180-1-2014 plus 4 amendment) star-1 rating completely self protected (csp) distribution transformers with having provision of lt bushing box
Tender For corrigendum : supply of 40 kva, 11 0.433 kv, aluminium wound eel1 star1 rating completely self protected csp distribution transformers with having provision of lt bushing box as per tn 2025