Tender For supply of line materials under electric supply area medininagar - electrical items :, hot dip galvanized from fabricated iron materials - 33 kv v cross arm (100x50x6) 19.7 kg (galvanized) for rail , 33 kv pole top bracket (100x50x6) 2.9 kg for rail (galvanized), , back clamp for 33kv v cross arm for rail 3.2kg, , 33kv dp channel (100x50x6mm) 45.5kg, , support clamp for 33 kv dp channel for rail 1sets=4pairs 9kg, , 33 kv v cross arm (100x50x6) 19.7 kg (galvanized) for psc pole 400 kg. 19.2kg, , 33 kv pole top bracket (100x50x6) 2.9 kg for 400kg.psc pole (galvanized), , 33kv tapping channel (100x50x6) mm 23 kg, , back clamp for 33kv cross arm for psc pole 400kg.3 kg, , 33kv dp channel (100x50x6) mm 45.5 kg, , support clamp for 33 kv dp channel psc pole 400kg. 1sets=2pairs 6kg, , side stay clamp 400 kg psc pole (galvanized) 1.92kg, , angle stay clamp 400 kg psc pole (50x8) 1.92 kg (galvanized), , 33 kv cross bracing for dp structure (50x50x6) 64.3 kg 1 set=4 pc, , clamp for cross bracing suitable for rail/psc pole 400 kg 1 set 4 pc 3.6 kg, , 11kv v cross arm (100x50x6) 14.6 kg (galvanized) for psc pole 200 kg., , 11 kv pole top bracket (100x50x6) 2.1 kg for 200kg.psc pole (galvanized), , back clamp for 11kv cross arm for psc pole 200kg. 2.8kg, , 11kv dp channel 75x40x6mm 41.3 kg, , support clamp for 11 kv dp channel psc pole 200kg. 1sets 2pairs 4.4 kg, , 11kv tapping channel 75x40x6mm 21 kg, , side stay clamp 200 kg psc pole (galvanized) 1.08kg, , angle stay clamp 200 kg psc pole (50x8) 1.08 kg (galvanized), , 11 kv cross bracing for dp structure (50x50x6) 64.3 kg 1 set=4 pc, , clamp for cross bracing suitable for rail/psc pole 400 kg 1 set 4 pc 3.6 kg, , transformer base channel for dss 1set=2pc 52.63kg, , top channel for dss (100x50x6mm) 52.63kg 1set=2pc, , channel for hg fuse set 1set=-2pc 38.6 kg, , channel for ab switch (100x50x6mm) 52.63 kg 1set=2pc, , support clamp for dss 1set=2pair for 11 kv top, , channel/ab switch base channel/tr base channel & hg fuse set channel 9.6 kg, , transformer belting (50x50x6 mm) & belting support (40x40x6 mm) [galvanized] (52.3 kgs.), , lt distribution bus bar (35x35x6mm) 1set=2pair, , 33kv ab switch structure (549 kg)/set, , 11kv ab switch structure (549 kg)/ set, , 33kv post insulator structure (55 kg/)/set, , 11kv post insulator structure (55 kg)/ set
Tender For supply of line materials under electric supply area medininagar - electrical items :, 33kv disc insulator with h/w fitting (polymer) 90kn, 33kv pin insulator with pin (polymer) 10kn, 33kv post insulator 10kn
Tender For supply of line materials under electric supply area medininagar - electrical items :, 33kv gi stay set (1900x20mm) with stay wire 7/10 swg and two gay insulator, 11kv gi stay set 1800x20mm with stay wire 7/10 swg and two gay insulator, 11kv gi stay set 1800x16 with stay wire 7/16 swg and two gay insulato
Tender For supply of line materials under electric supply area medininagar - electrical items :, suspension clamp assembly suitable upto 70-95 sqmm 12 messenger (including 1 nos suspension clamp with bracket, 2 mtr stainless steel strap & 2 nos ss buckles) and eye hook., dead end clamp suitable above 70 sqmm 12 messenger (including 1 nos dead end clamp bracket+ 1 nos dead end+ 2 mtr ss strap+ 2 nos s.s buckle minimum breaking load 15 kn), peircing connector for lt ab cable, smdb box, lt shackle insulator with straps
Tender For supply of line materials under electric supply area medininagar - electrical items :, 11kv post insulator 10 kn 1set=3pc, 11kv disc insulator with h/w fitting (polymer) 70kn, 11kv pin insulator with pin (polymer) 10 kn
Tender For corrigendum : supply of roof line supporting insulator conforming to clw specn no. clw/es/ac/i-1 alt-l and clw drg. no. clw/es/sk-2/ac/i-1 alt-l . [ warranty period: 30 months after the date of delivery ]
Tender For supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding
Tender For ghrssidc/e-t/2026-27/646 - electrical fabrication - a, la cross arm clamp for 7.5 mt rcc pole (gal v) - cee/e/523, sa cross arm clamp for 7.5 mt rcc pole (gal v) - gec/e/523, la cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, sa cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, la cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, sa cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, la cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, sa cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, la cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, sa cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, la stay clamp for 60 lbs/yd rail pole (gal) - cee/e/469, sa stay clamp for 60 lbs/yd rail pole (gal) - cee e 469, la stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, sa stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, la stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, sa stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, la stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, sa stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, la stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, sa stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, 11 kv v shaped cross arm (gal v) - cee e 408, 33 kv v shaped cross arm (gal v) - cee e 408, b type modified distribution box - cee e 386, a type street light meter box with clamps - cee e 386, stay set for 11 kv lt line - cee e 500, stay set for 33 kv line - cee e 500, turn buckle& eye bolt for 33 kv line - cee e 513, turn buckle& eye bolt for 11 kv line -cee e 466, cast iron packing piece 90 lb for rail pole - cee e 514, top insulators fitting for rcc pole - cee e 506, 4 pin angle type cross arm - cee e 702, 4 pin channel type cross arm - cee e703, 2 pin angle type cross arm - cee e704, 2 pin channel type cross arm - cee e 705, earthing pipe - cee e 467, sa cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa bottom clamps for fixing street light fixtures for 7.5/9mtrs rcc pole galvanised 25 mm pipe - cee e 12, sa top bottom clamps for fixing street light fixtures for 7.5 mts rcc pole galvanised 25 mm pipe - cee e 12, la top clamps for fixing street light fixtures for 7.5/9 mts rcc pole (gal v) 40 mm pipe - cee e 612a, sa top clamps for fixing street light fixtures for 7.5 rcc pole - cee e 612a, gi nut and bolts in various sizes electro galvanised, gi pins for lt pin insulator, gi pins for 11kv pin insulator, gi pins for 33kv pin insulator, gi bent pipe of nominal base 25 mm, 1 mts long for tube light fixture - cee/e 618, gi bent pipe of nominal base 25 mm, 1.5 mts long for hpsv lamps - cee/e 593a, b type modified distribution box with mccb and kit kat fuses as per cees specifications / drawings, metal parts for shackle insulators as per cees specifications, gi bent pipe of nominal base bar 40mm x 3 mts long (medium class) the pipe shaft should conform to is : 1239 (part i) 1973 as amended upto date - ee/ii/21/2009, hot dip galvanised earthing strips of size 30x160x5mm, hot dip galvanised earthing strips of size 100 x 360 x 3mm, g.i bent pipe nominal bore 40 mm ce/e xi for hpsv lamps - cee/e 593a, metal parts for disc insulator as per department 4 bolted. as per department specification & drawing - 60/4/va/cee/tech/2019-20/1282, metal parts for disc insulator 3 bolted - 60/4/va/cee/tech/2019-20/1282, kit kat fuse 100 amps, kit kat fuse 200 amps, kit kat fuses 300 amps, kit kat fuse 400 amps, tinned copper fuse wire of various sizes, aluminium crimping lugs 25 sq.mm, aluminium crimping lugs 35 sq.mm, aluminium crimping lugs 50 sq.mm, aluminium crimping lugs 70 sq.mm, aluminium crimping lugs 95 sq.mm, aluminiu
Tender For supply of panto foot(mounting) insulator for locos & emus/memu and roof line insulator for emus/memu.specn/drg no: as per clw's specn.clw/es/ac/i-1/l and clw's drg no. clw/es/sk-4/ac/i-1/l [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of carriage of pcc and stp poles 8.5, 11 and 13 mtr , carriage of line material , erection of pcc and stp poles 8.5, 11 and 13 mtr , erection of double poles 8.5, 11 and 13 mtr , installation and fixing of 11 kv tpmo. , erection and grouting of stay set , providing and fixing of insulator , laying of acsr weasal, rabbit and dog conductor. , erection of abc conductor , grouting of pcc and stp poles , making of plinth , fixing of earthing rod , chopping of tree branches , providing and fixing of clamps of lt , providing and fixing , carriage and installation of 25 kva transformer , carriage and installation of 63 kva transformer , carriage and installation of 100 kva transformer , carriage and installation of 400 kva transformer , dismantling of old pcc and stp poles , dismantling and removal of conductor , erection of section tee pole , carriage and installation of lt dist box , provding and fixing, filling cable joints , safe carriage of cables , laying of under ground cable , laying of overhead cable , guarding of 11 kv line by gi wire , safe carriage and installation of metering unit , safe carriage and installation of metering cubicle , provding and fixing wearing gi pipe