Tender For corrigendum : operation and maintenance (electro-mechanical) services of 100 bedded hospital at base hospital chandanwari during shri amar nath ji yatra-2026.
Tender For repair maintenance of electromechanicalservices in residential quarter in da flat sindhora kalan sindhora khurd gulabi bagh model town delhi. sh renovation repair of electrical work in typeii iii iv and typev flats due to new allotments cable laying st
Tender For design, engineering, supply, installation, testing and commissioning of cable management system for the shore to ship power supply facility at coal berth i and coal berth ii of paradip port.
Tender For supply of 24-port enhanced cat-6 fully loaded modular type patch panel , modular wall plate with abs plastic body, loaded , modular straight shuttered single port face plate with abs plastic body , 0.5 m cat 6 utp patch cord , 3m cat 6 utp patch cord h , 19 inch, ul certified 12 u wall mountable rack fully loaded , horz cable organiser 1u chanel on front , fiber liu, drawer type, loaded, 6 port , i o box set , fiber liu, drawer type, loaded, 24 port adapter , patchcord,sm os2,duplex lc-sc,pc type,3m , cat 6, 4 pair utp cable , 100 x 50 mm pvc cable management system , 100 x 50 mm pvc cable management system along with accessories , 25mm pvc pipe for fiber cable , hdmi 1x4 splitter 4k , hdmi 4k 5 mtr cable for pc , hdmi 4k 2 mtr cable for splitter to hdmi converter , hdmi to lan converter 60mtr , labour charges * /bid number : gem/2026/b/7637439 + /dated: 09-06-2026 ' ' / bid document 1 / 22
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For repair and maintenance of electromechanicalservices at ito nungambakkam, chennai-34. sh: repair and maintenance of wet riser system etc., in ito (main, annexe & wanaparthy) agaram and sigaram building at 121, mg road, chennai-34.subwork/packages:annual maintenance contract of firefighting system at ito (main, annexe & wanaparthy building) agaram and sigaram building i/c materials.
Tender For repair and maintenance of electromechanicalservices at ito nungambakkam, chennai-34. sh: repair and maintenance of various capacity lifts etc., in ito (main, annexe & wanaparthy building) agaram and sigaram buildings at 121, mg road, chennai-34.subwork/packages:annual comprehencsive maintenance and servicing contract for 02 nos 01 no lift at entry of canteen way 01 no lift at main entry near reception 13 passenger kone lifts at ito wanaparthy building g plus 7 floors for a period of 24 months
Tender For supply and installation or urs at various areas of zone south, jodhpur - providing & laying xlpe insulated & p.v.c. sheathed armoured aluminium cable confirming to is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) including testing commissioning etc. as required of following size.10.0 sq. mm x 4 core, supply & installation of unified regulation system (urs) for existing street light that meets the following specification.the system must feature a 240mhz dual core processor with gsm/gprs communication capabilities and support for ota firmware updates.it should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.the urs must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to ip55 standards,and be fire retardant,weatherproof,and rustproof. the system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5kw and 3 phase street light load upto 8.5kw and should come with 2pole/4pole mcb upto 25a/40a at output for short circuit protection .having a 2-year warranty urs will be installed at site as per direction of engineering incharge. (size 570*520*190mm)