Get complete information related to latest Electrolyser Spare Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrolyser Spare Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrolyser Spare Tenders.
Tender For procurement of physics lab equipments - procurement of physics lab equipments, ic regulated battery eliminator ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., sonometer apparatus sonometer with meter scale attached along with knife edge, tuning forks set 256, 384, 512 ranges, hammer, slotted weight - 500 gm each to a total of 3 kg. brass wire (5 m), potentiometer apparatus it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements., solar cell kit the apparatus consist of variable dc power supply, led, solar cell and two multimeters (or an ammeter and a voltmeter). a variable dc power supply of 0-5v. light source is provided by led. the illumination intensity of the led can be controlled, wheat stones bridge kit series arm: four decade dials in steps of thousands, hundreds, tens, & units of ohms. ratio arm: the ratio arm of the bridge is capable of selecting multiplying factor of 0.001, 0.01, 0.1, 1, 10, 100, 1000 for resistance measurements., ohms law verification kit battery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), standard resistance coil of 1, 2 ohm (2-set) wound on a wooden bobbin
Tender For corrigendum : purchase of non-consumables for physics lab in basic engineering (first year) department - purchase, joule calorimeter - copper vessel, battery eliminator 3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0 2a), voltmeter (0-5v), thermometer (alcohol), stop clock, ic regulated battery eliminator- ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., galvanometer- moving coil type, 30-0-30 scale, unbranded with bhel specification-sensitivity 0.143mm/v, voltmeter- dc voltmeter; range 0 10 v, analog, ammeter- dc (0 - 2 amp), parallelogram apparatus- parallelogram law of forces apparatus fitted with stand, decade resistance box- resistance box 12 month warranty (dial type) -manganin coil- 2 dials, sonometer apparatus- sonometer with meter scale attached along with knife edge, tuning forks set 256, 384, 512 ranges, hammer, slotted weight - 500 gm each to a total of 3 kg. brass wire (5 m), travelling microscope- branded travelling microscope 0 200 mm horizontal and 0-150 mm vertical measurement, potentiometer - it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements., viscosity apparatus stokes apparatus with metre scale attached and long cylindrical glass jar, glass beads small size (1 box), screw gauge (0-15 mm), rheostat - high-grade ceramic tube, oxidized resistance wire, 0.5a 5a, range 10 100 ., deflection magnetometer apparatus - deflection magnetometer apparatus with compass box and two short bar magnets, solar cell kit- the apparatus consist of variable dc power supply, led, solar cell and two multimeters (or an ammeter and a voltmeter). a variable dc power supply of 0 5v. light source is provided by led. the illumination intensity of the led can be controlled, wheatstone bridge kit- series arm: four decade dials in steps of thousands, hundreds, tens, & units of ohms. ratio arm: the ratio arm of the bridge is capable of selecting multiplying factor of 0.001, 0.01, 0.1, 1, 10, 100, 1000 for resistance measurements. two press keys are provided, one marked b is for battery & one marked g is for galvanometer one toggle switch is provided for internal battery a sensitive galvanometer is provided in the bridge., ohms law verification kit- battery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), standard resistance coil of 1, 2 ohm (2-set) wound on a wooden bobbin, boyle s law apparatus - the apparatus includes the quill tube, a retort stand, a clamp, and a mounted meter scale. quill tube specifications: length: approximately 50 cm. bore diameter: uniform bore, roughly 1 mm to 2 mm. construction: glass tube with one end sealed. trapped substance: a mercury pellet (or thread) of length 10 to 15 cm is introduced to enclose a column of air. mounting: attached to a half-meter or meter scale., torsional pendulum - torsional pendulum metallic disc, symmetrical masses and pendulum stand, steel wire, compound bar pendulum- one meter long iron strip well painted with holes at a distance of every 5 cm and also with pair of brackets and a heavy base table top stand with stop clock, helical spring apparatus-- structure: a rigid support mounted on a heavy metal base, typically cast iron, to ensure stability during tests. springs: high-tensile steel spiral springs, typically (approx 25 mm) diameter, (100 mm) long. measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement. loading mechanism: a, typically (50g), hook-attached weight hanger at the bottom.pointer: a fine pointer attached to the bottom of the spring moves along the scale. accessories: includes a set of slotted wei
Tender For supply of femtosecond laser source , multi axis cnc motion system , aberration corrected focusing optics , system integrated controller , in line process vision system , camor cad micromachining software , pneumatic vibration isolation system , laser power meter , consumables and essential spares kit , debris removal and exhaust system , vacuum chuck and pumping system , laser safety enclosure , machine andon or warning light , laser safety goggles , document and manuals , test pieces for machining trails , levelling and anchoring materials , packaging and forwarding
Tender For supply of multimedia lcd projector, specification: 1. projector: led/lcd technology. 2. projection method : front and rear both. 3. brightness : more than 4000 lumen 4. min. life of light source : 6000 hrs 5. native resolution : 1920 x 1080 (full hd) 6. aspect ratio: 16:9 7. connectivity : usb 2.0 type a, usb 2.0 type b, vga in, hdmi in, wi-fi. 8. accessories : to be supplied with 15 mtrs vga cable, hdmi cable, usb cable, power cable including casing, wall spring action projector screen (5 ft x 7 ft) , ceiling mount kit. 9. 120 % optical zoom. 10. wireless screen share. 11. contrast ratio (min.): 15000 12. inbuilt speaker. 13. type of light source : uhp/ uhe/ uhm. 14. keystone correction : automatic & manual both. 15. noise level : 28 db in echo mode and 37 db in normal mode. 16. onsite oem warranty : 03 years. 17. make : epson/ sony/ similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of equipments for physics and chemistry lab for first year department - digital balance: load capacity: minimum 500 g readability: 0.01 glinearity: 0.02gdisplay: lcd/ledtare function: required top pan typepower supply: 220 240 v ac, 50 hz", galvonometer moving coil type, 30-0-30 scale, unbranded with bhel specification-sensitivity 0.143mm/v, voltmeter dc voltmeter; range 0 10 v, analog, ammeter dc (0 - 2 amp), decade resistance box resistance box 12 month warranty (dial type) -manganin coil- 2 dials, potentiometer apparatus it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements., deflection magnetometer apparatus deflection magnetometer apparatus with compass box and two short bar magnets, solar cell kit the apparatus consist of variable dc power supply, led, solar cell and two multimeters (or an ammeter and a voltmeter). a variable dc power supply of 0-5v. light source is provided by led. the illumination intensity of the led can be controlled
Tender For for basic engineering department lab equipments are required as per new syllabus - upgradation of labarotariesbasic engineering, digital electronic balance/analytical balanceload capacity: minimum 500 greadability: 0.01 glinearity: 0.02gdisplay: lcd/ledtare function: requiredtop pan typepower supply: 220 240 v ac, 50 hz, laboratory heating mantle (knitted glass yarn)capacity: 500mltemperature range: ambient to 350 cenergy regulator/control knob: requiredpower supply: 220-240 v ac, 50 hz, joule calorimetercopper vessel, battery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), thermometer (alcohol), stop clock, hot platetop plate material: cast ironplate size: minimum 8 inch diameterpower rating: 2000 wtemperature range: ambient to 200 c minimumthermostatic temperature control: requiredpower supply: 220 240 v ac, 50 hz, electric bunsen burnerelectrically operatedenergy regulator/ control knoboperating temperature 800 cbody: stainless steelpower supply source: corded electric, supplied with aheavy-duty, heat-resistant,earth-grounded, 3-pin power cord (minimum length 1.2 meters).power consumption: between 350 and 500wpower supply: 220-240 v ac, 50 hz, water distillation unitoutput capacity: 4 litres per hour (lph)ph value: 5.5 to 7.0conductivity (raw water distillation):3.0 4.0 s/cm or lessglassware material: borosilicate 3.3 glass (pyrex/duran equivalent)heating elements: silica-enclosed quartz heaters or chromium-plated element variantspower supply: 220 240 v ac, 50 hz / 60 hz, single phaseautomatic water level cut-off, ic regulated battery eliminator2v to 12 vic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., voltmeter0 to 5 volt 0 to 5 ampdc voltmeter; range 0 10 v, analog, ammeter0 to 5 volt 0 to 5 ampdc (0 - 2 amp), rheostat50 ohms 2.8 amperes high-grade ceramic tube, oxidized resistance wire, 0.5a 5a, range 10 100 ., solar cell kitcharacterstic study kit with solar panelthe apparatus consist of variable dc power supply, led, solar cell and two multimeters (or an ammeter and a voltmeter). a variable dc power supply of 0-5v. light source is provided by led. the illumination intensity of the led can be controlled, wheatstone bridge kittypically 0.001 ohm to 11.11 mohm with inbuilt 4.5v/9v battery series arm: four decade dials in steps of thousands, hundreds, tens, & units of ohms.ratio arm: the ratio arm of the bridge is capable of selecting multiplying factor of 0.001, 0.01, 0.1, 1, 10, 100, 1000 for resistance measurements. two press keys are provided, one marked b is for battery & one marked g is for galvanometer one toggle switch is provided for internal battery a sensitive galvanometer is provided in the bridge.
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For purchase of equipment for the department of physics--- weight box (gm weight & milligram weight), simple pendulum (bob), young modulus, voltmeter (0-10 volt dc), galvanometer (0-30), voltmeter dc (0-3 volt), battery eliminator (power supply, dc output, 2-12 vol 750ma), post-office box, tangent galvanometer (50 turns coil), spherometer, led and laser diode characteristics apparatus, hybrid parameters of transistor, tomcats pendulum , bar pendant , damping oscillation in various mediums , thermal expansion apparatus , reported apparatus , archimedes principle apparatus , biot-savart law apparatus , photodiode characteristics apparatus , ldr characteristics apparatus, tunnel diode characteristics apparatus, rc coupled amplifier kit, rc phase shift oscillator using opamp, deflection magnetometer set, opamp kit, surface tension by capillary rise, co-efficient of viscosity by poiseuille's method., co-efficient of viscosity by stokes law with photogate, lcr series resonance apparatus, lcr parallel resonance, spring constant set, laser red for diffraction, laser green for diffraction, laser violet blue for diffraction, grating with different grating constant, vibration magnetometer, hall effect apparatus, bh curve tracer, quincks method, piezoelectric transducer kit, mercury lamp, fresnel's biprism diffraction apparatus, bread board with power supply, balmer series and rydberg constant set up, hydrogen discharge tubes for the rydberg constant set up, mercury lamp, michelson interferometer with light source, fresnel bi-prism complete set-up with sodium source, set-up for millikan's oil drop experiment, set-up for de-broglie wavelength. measurement, zeeman effect, lattice parameter se, electron spin resonance , fourier analysis kit , microwave bench set up