Tender For supply of electro-mechanical & instrumentation items for mass balancing reservoir (mbr- supply of pump starter panel including individual vfd for 125 kw (02w+1s), supply of 1.1 kv grade cable- aluminium conductor supply, laying, testing & commissioning 1.1 kv grade, xlpe insulated, stranded aluminium conductor cables, a) 3.5 c x 185 sq.mm, b) 3.5 c x 300 sq.mm, 1.1 kv grade, xlpe insulated, stranded copper conductor, galvanised steel flat strip / round wire armoured, extruded pvc type st2 sheathed, heavy duty cable, a) 3 c x 2.5 sq.mm, supply of gi perforated type cable trays with returned edge / flange, fabricated from 2.0 mm thick sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after fabrication as per is 2629-1989 / is 4759-1984 including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification, a) 450(w) x 75(h) x 2.0 mm thick, b) 300(w) x 35(h) x 2.0 mm thick, c) 100(w) x 35(h) x 2.0 mm thick, mechanical items, supply of di pipes k-9, dia 500mm, di fittings 500mm, , , , , , for 300 mm dia butterfly valve, for 500 mm dia butterfly valve, for 600 mm dia butterfly valve, instrumentation items, non-return valve 300 mm dia, , , , supply 10cx 1.5 sq.mm signal cable, supply 1px 1.5 sq.mm signal cable, supply 2cx 1.5 sq.mm signal cable, supply horizontal end suction pump 780m3/hr @40m head, impeller: ss, shaft: ss, casing: ci including pumps with mechanical seal. 120 kw 2w+ 1s, supply of 1/2" pressure gauge 0-10 bar,, supply of butterfly valve, supply of electric actuator, supply of electromagneticflowmeter 500 mm dia, supply of expansion bellow, supply of pressure transmitter, 0-7 kg/cm2,, supply of zero velocity valve 500mm dia
Tender For supply, installation, testing, calibration and commissioning of the electromagneticflowmeter, supply of ph meter, supply of tds meter and other consumable material such as urea, dap, bacteria culture, molasses seera, chlorine & alum for the usage in stp at south campus of iit mandi.-supply, installation, testing, calibaration and commissioning of the electromagnetic digital flowmeter of 40mm dia, complete with all required instilation and fitting acessories including flanges, gaskets, nut-bolts etc. along with 1 year manufacturer warranty against manufacturing defetcs all complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supply of ph meter (range-0-14ph)all complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supply of tds meter (range-0-9990 ppm) all complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supplying of urea for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supplying of di-ammonium phosphate(dap) for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supplying of bacteria culture for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts..,supplying of molasses seera for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supplying of sodium hypochlorite (chlorine) for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.,supplying of alum for stp complete as per the entire satisfaction and direction of engineer-in-charge upto all lead and lifts.
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For bid to ras supply of supply of electro magnetic flowmeter 150 mm size , supply of electro magnetic flowmeter 100 mm size , integration of 150 mm electromagneticflowmeter with plc_rtu , supply and laying of cable for flowmeter , complete installation and commissioning of flowmeter , complete installation and commissioning of pressure sensor
Tender For supply, installation, testing and commissioning of clamp-on type ultrasonic flowmeter, online continuous effluent monitoring monitoring system, programmable iot panel gsm/gprs, electromagneticflowmeter, open channel ultrasonic flowmeter and all accessories co
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., level measurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water level measurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement., flow measurement using electromagn etic flowmeter(item code: g021)specifications: medium: water (salt water / bore well water). electromagneticflow measurement: instantaneous flow rate and totalized flow indication. electromagneticflowmeter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.