Get complete information related to latest Electrometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrometer Tenders.
Tender For establishment of integrated analytical laboratory for demil plant - hot air oven, magnetic stirrer, heating cooling circulator, rotary evaporator with chiller and vacuum pump, ultrasonic cleaner, high speed orbital shaker, vacuum pump, peristaltic pump, benchtop ph meter with orp electrode & necessary buffers, electrode storage solution & electrode cleaning solution, dissolved oxygen meter, turbidity meter, bench top multi-parameter tester (conductivity, tds, salinity, ph), bod incubator, cod digestor system, vortex mixer, effluent sampling manifold (esm) with controlled cobustion chamber (ccc), analytical balance, laboratory balance, mini centrifuge machine, gyro shaker, melting point apparatus, electric bunsen burner, deep freezer, laboratory rrefrigerator, ultra-pure water purification system, muffle furnace, double distillation unit, probe sonicator, heating mantles, systematic design, partitions, equipment console with work and storage modules, chemical reagent console with work and storage modules, instrument console with work and storage modules, overhead storage console, extended office console, office console, file storage console, record management console, back positioning module, fire protection modules, fume closet, exhaust manifold, power reserve (40 kva), elemental (chnso)analyzer, inductively coupled plasma - mass spectrometer (icp-ms), microwave digestion system, amc cost for 1st year after expiry of warranty period, amc cost for 2nd year after expiry of warranty period, amc cost for 3rd year after expiry of warranty period
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f