Get complete information related to latest Electronic Lamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electronic Lamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electronic Lamp Tenders.
Tender For corrigendum : supply of battery operated led based torch light cum flashing hand signal lamp, rdso specificati on no:rdso/spn/195/2019 (attached), version-3.0, effective from 1st january 2020 with battery. [ wa rranty period: 30 months after the date of delivery ]
Tender For supply of mt tools and maint items - de spanner 12x13 , adjustable spanner8 , cutting plier , tool kit bag canvas , screw driver 12 300mm , screw driver 8 , first aid kit , ring spanner 10 x 11 , ring spanner 12 x 13 , ring spanner 18 x 19 , phil screw driver 100mm long 6 dia , tube hose pump , chassis record beg , assy wheel nut m 20 x 2.5 , screw driver , rubber packing , single filament fhl 12v , bush engine cleaning , rubber hose radiator to thermostate , rubber hose , scabbard dah mk-3 , bock wooden for jack , chock large , tin rectangular 5 ltrs , ms fabricated parking chock , push tap ss , assy spacer block complete , tyre lever t l6 , hand lamp with cable of length 10mm , adjusting screw , fog light 12v , bulb f 15 w for rear indicator , bulb 12v for front indicator , block jack , box tin lamp filament , bulb 12 3 21 6 for stop lamp , funnel oil 152mm oval , inserter and remover tyre valve , philps head screwdriver 100mm longtip , de spanner 5 8 x 9 16 sae , de spanner 14 x 15mm , tool box , bulb turn signal 12v and 21w , jack with handle 12ton , pvc hose nipple , sump packing , rubber packing main hole cover , de spanner 11 x 13 , chocks stowage vehicle timber , inspection lamp with 10 mrs long table
Tender For el.d.c.no.centre/2409/2025 removal of 172 nos of 8 mtr street lamp post at anna salai anna arivalayam to nandanam signal in dn 122 zone 09 deposit work highways
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi