Web Analytics Made Easy - StatCounter

Electronic Load Ammeter Tenders

Get complete information related to latest Electronic Load Ammeter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electronic Load Ammeter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electronic Load Ammeter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45532117 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For standing order/rate contract for supply of instrument materials on door delivery and callup basis at hbl plant sugauli, east champaran and lauriya, west champaran, bihar. - load cell 100 kg strain gauge type, make-avery/ perciamoleen, 4 load cell junction card 4 input 1 out, make-avery/ perciamollen, signal isolater optical isolation type signal input/output 4-20 ma supply 18- 260 vac/vdc, make-radix, signal converter 0-5 a to 4-20 ma supply voltage 18-240 vac/vdc, make-radix./masibus/ p&f, zss controller with its proximity supply voltage 230vac, make-masibus, hall s effect type top roller lift sensors (asd-he-trls-10) and indicatingtransmitters (asd-he-trlit-1005-1-2), make-yu tech, infra red type donnelly chute level sensors, indicators & transmitters, make-yu tech, hall s effect type cane blanket level sensors( asd-he-cbls-10) and indicatingtransmitters (asd-he-cblit-1005-1-2), make-yu tech, pressure transmitter strain gauge type range 0-16 kg/cm2 output 4-20 ma looppowered processe connection 1/2 inch male threaded, make- honywell/ypkogawa, on off controller input signal universal, 2 relay output on set point, make-honywell, size 96x96 supply 230vac, weighing controller/ indicator for beltscale model no=40 bs, make-perciamollen, directional control solenoid operated valve (ng10): 4we 10 d a01-24dg/v, make-hydac, direction control valve, solenoid operated (ng6) type: 4we 6 d a01-24dg/v, make-hydac, pressure relief valve sandwich plate type for ng06(4we 6 d a01-24dg/v), pressure range 210 kg/cm2flow 120 l/min, manual adjustment, fkm sealing, make-hydac, digital pressure indicator cum transmitter range 0- 300 kg/cm2 model no eds 3000, make-hydac/ above equivalent, make parker, strain gauge type dp switch across filter range 0.05kg/cm2, make-hydac/ parker, pnp pproximity switch 2 wire range 15 mm od 30 mm male supply 24 vdc p&f, lvdt range 0-1100 mm probe od 10 mm 1/2 inch threaded connection, out put 4- 20 ma model no. c01-1100-000 make hydac/ above equivalent, make-mts, modelno. rhm1185md601a01, level indicator cum transmitter loop powered output 4-20 ma range 1000mm fluid hydaulic oil, make-parker, part no. 110558, model no. hblt-a1-6u, digital temperature indicator cum transmitter head mount range 0-100c probe od 8 mm loop powered output 4-20 ma, make-hydac/ parker probe length 700mm, solenoid coil connector 4 pin with led indicator, size-20mmx20 mm, lvdt probe connector with 10 mtr cable lid connector type 6 pole, m16 dinfemale type, make-any reputed, plug in power relay with base, coil voltage 24 v dc model no my2n, make-omron, rtd pt100 type length 500mm od 6 mm make thermostatic or any reputed, temperature transmitter cum digital indicator remote field mounting input universal, loop powred, output 4-20 ma, make-rosemount/ honywell/abb/yokogawa/p&f hart enable, 8 channel rtd transmitter input rtd pt100( field interface boards 8 channel linearized rtd/tc input), output 4-20 ma model no-mas-ai-u-o8d-9-1-0, make- masibus, pressure transmitter lvdt type range minus 2 kg/cm2 to 16 kg/cm2 loop powred output 4-20 ma 1/2 inch female threaded process coneection, field mounting hart enable, make-abb/ emerson/ rosemount/ yokogawa, diffrential pressure transmitter range minus2 kg/cm2 to 2 kg/cm2, field mounting process connection 1/2 inch ntp female threaded loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/ emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at higher side loop powered 4-20 ma, output hart enable, make-abb/ yokogawa/ rosemount/emerson, diffrential pressure transmitter range minus 2 kg/cm2 to 2 kg/cm2, field mounting process connection 3 inch flanged diapharm type at both side 4 mtr capilary, loop powered 4-20 ma output hart enable, make-abb/ yokogawa/rosemount/ emerson, perssure gauge burden tube type range 20 kg/cm2 dial size 6 inch process connection 1/2 inch ntp male threaded, make-warri/

CTN :45549158 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]

CTN :45410030 Due date: 15 Jun, 202615 Jun, 2026 35.0 Thousand
Tender For corrigendum : supply of biological indicators for low temperature steam and formaldehyde sterilization processes (q2)

CTN :45516505 Due date: 26 Jun, 202626 Jun, 2026 1.00 Lacs
Tender For tender for repairing and calibration of temperature indicators installed on boiler , work of repairing, calibration and rewiring of superheated wash water temperature control system , laying of comprehensive cable, installation of thermocouple and commissioning of indicators at the boiler station , work of repairing, rewiring, overhauling and commissioning of d- superheating system of exhaust line , repairing and commissioning work of temperature indicators of sulfur furnace , laying of compressive cables of sulfur furnace, installation of sensors and commissioning of temperature indicators , to carry out installation and commissioning work for raw-sulfated juice, clear juice, exhaust steam and injection water inlet temperature , over hauling, rewiring and recommissioning of auto drum water level control system of boilers , rewiring and recommissioning of high or low alarm system on boilers for water level , overhauling, rewiring and recommissioning of boiler steam generation system , overhauling, rewiring and recommissioning of boiler feed water measurement system

Central Government And Public Sector

CTN :45370557 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For corrigendum : supply of digital temperature controllers cum indicators , microprocessor based digital temperature indicator cum controller

CTN :45479514 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]

Central Government/Public Sector

CTN :45467531 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of mandatory spares for chemical dosing skids , mandatory spares for oxygen dosing skids - drive shaft cum worm , drive worm wheel , connecting rod plate , cross head guide bush , plunger , plug , oil seal , washer , gland nut , electronic transmitter , transmitter of all type, ranges & model no. (for measurement of pressure, differential pressure flow, level, etc). , pressure transmitter , differential pressure transmitter , level transmitter , temperature element , local indicators like temperature gauges, pressure gauges, differential pressure gauges, flow gauges, flow meter etc. , pressure gauge , pressure gauge , diff. pressure gauge , process actuated switch devices includes all type of pressure, differential pressure, flow, , temperature, differential temperature, level switch devices. , process connection piping (for impulse piping/tubing, sampling piping/tubing and air supply piping , applicable) , valves of all types & models , 2 way, 3 way, 5 way valve manifolds , fitting , measuring instrument , electronic transmitters , transmitter of all type, ranges & model no. (for measurement of pressure, differential pressure flow, level, etc). , level transmitter (ultrasonic / radar type) , temperature element , local indicators like temperature gauges, pressure gauges, differential pressure gauges, flow gauges, flow meter etc. , process actuated switch devices includes all type of pressure, differential pressure, flow, temperature, differential temperature, level switch devices. , pd type flow transmitters , any other instrument (if applicable) , process connection piping (for impulse piping/ , valves of all types & models , 2 way, 3 way, 5 way valve manifolds , fitting , purge meter , filter regulators , mass flow controller , control valves actuators & accessories , pneumatic & electro-hydraulic actuator assembly , valve trim (including cage, plug, stem, seat ring, guide busing etc.) , diaphragm 'o' rings seals etc, all types of make etc. , pressure gauges of all types of make, rating, etc. , solenoid valves (if applicable) , positioner unit (complete unit) , pneumatic air filter/regulator of each type, makes rating etc. , air lock relays

Central Government And Public Sector

CTN :45454198 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For the offered equipment is a fiber media converter, model gomc-bi3512-20 or equivalent , designed for conversion between 10/100/1000base-tx copper ethernet and 1000base-fx optical fiber networks. the converter supports ieee 802.3, ieee 802.3u, ieee 802.3ab and ieee 802.3z standards, ensuring compatibility with gigabit ethernet networking applications. it provides one rj45 copper port with auto-negotiation support for 10/100/1000 mbps data rates and one sc type bi-directional fiber port operating at tx 1310nm / rx 1550nm wavelength with transmission distance up to 20 km over single-mode optical fiber. the device supports full duplex flow control and half duplex back pressure for efficient data transmission. led indicators are provided for power, optical link/activity, full duplex status, twisted pair link/activity and transmission rate indication. the converter operates on dc 5v, 1a power supply with optional external or internal power supply configuration and power consumption less than 3w. it is designed to operate in environmental conditions ranging from -10?c to +55?c with storage temperature from -40?c to +85?c and relative humidity from 5% to 95% non-condensing. the unit dimensions are 94mm ? 70mm ? 26mm for external type and 140mm ? 110mm ? 30mm for internal type. the product is suitable for network communication, ftth/fttb/fttx applications, isp backhaul networking and subscriber end connectivity. the equipment complies withce, fcc and rohs certifications. [ warranty period: 36 months after the date of delivery ] ]

CTN :45386617 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
 Loading, Please wait...

Connect us via What's Up