Web Analytics Made Easy - StatCounter

Electronic Meter Repair Tenders

Get complete information related to latest Electronic Meter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electronic Meter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electronic Meter Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40577874 Due date: 05 Jul, 202505 Jul, 2025 NA
Tender For corrigendum : provision of ct pt and ct operated meter in trv and technical area at icgas daman

Central Government/Public Sector

CTN :40402775 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For bid to ras supply of general electrical items for maintenance work - 20 amp modular socket , 10amp modular switch , 20a 1p modular mcb , back entry bakelite fuse, 100 amps , back entry bakelite fuse, 63 amps , 20amp 2p mcb with encloser , gang box pvc 6way for switch socket w o , 1 inch pvc pipe , 1 inch pvc bend , 1 inch pvc elbow , 1 inch pvc junction box 3way , din rail mcb channel , capacitors 2.5 mfd, 440v for ceiling fan , 2 way junction box outdoor , 100 amp 4p bakelite connector , led driver , energy meter, 3 phase, ac , 3ph energy meter ct operated

CTN :40890690 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For supply of electrical general items - heavy duty switch disconnector fuse unit, tpn rating 250 amp. suitable , din fuse-link, make siemens , heavy duty switch disconnector fuse unit, tpn rating 125 amp. suitable , din fuse-link, make siemens , heavy duty switch disconnector fuse unit, tpn rating 125 amp. suitable , din fuse-link, with ss incloser big size make siemens , under voltage relay supply voltage 220-240, 50 hz type yu-1sda038312r1, make abb , closing coil supply voltage 220-240, 50 hz type yc-1sda038302r1, make abb , mccb 125 a 3pole , 50ka, make abb , motor circuit breaker rating 10a type: gv2me14, term/mag 6-10 a rocker make: schneider electric , power contactor 3pole coil voltage 110v ac, type: a185-30, make : abb , power contactor kit for abb make contactor, a185-30, , power contactor kit for abb make contactor, a145-30, , aux. contact for (abb make contactor a185-30) type cal18-11, 1no+1nc, make abb , power contactor 3tf47, 3pole, coil voltage 230v, 50hz, with 2no + 2nc aux contact, make siemens , power contactor 3tf34, 3pole, coil voltage 230v, 50hz, , make siemens , power contactor 3tf33, 3pole, coil voltage 230v, 50hz, make siemens , power contactor 3tf32, 3pole, coil voltage 230v, 50hz, with 1no aux contact, make siemens , ca5 x-01 (aux. contact), make abb , ca5 x-10 (aux. contact), make abb , 2no+1nc aux contact for (mnx9 contactor) , 3tx4010-2a-1no (aux. contact), make siemens , 3tx4001-2a-1no (aux. contact), make siemens , ca5-40e (aux. contact) make abb , ca5-22e (aux. contact) make abb , compact motor protection relay model: mm10 ct sec 5a aux. 230v ac make l&t , mcb schneider/abb make, 10 ka, , 63 a, 4 pole , 63 a, 3 pole , 63 a, 2 pole , 32 a, 4 pole , 32 a, 3 pole , 32 a, 2 pole , 25 a, 1 pole , a, 1 pole , 25a, 2 pole , 25 a, 4 pole , 63a, 4pole, 10 ka mcb, make: legrand/schneider/abb , with 1no+nc aux. contact , change over relay contact rating 3a. coil voltage 230 v 50hz , with base, make schneider/abb , change over relay contact rating 3a. coil voltage 24 vdc , with base, make schneider/abb , rotary handle operating mechanism for (630amp sfu, type os630d03-3, make abb) , hrc fuse link, type 3na, make siemens , 125 a, size 00 , 250 a, size 1 , hrc fuse link, type tia, make siemens 125 a, , kit-kat sm type (fuse holder), 125a , overload relay, make l & t, range: , 6-10a (mk1) , 9-14a (mk1) , 14-23 (mn5) , 20-33 (mn5) , 9-15 (mn2) , overload relay, make siemens, range: 25-40 a (3ua58) , abb make overload relay 18-25a , tc make overload relay 9- 18 a , terminal block, make connectwell/ wago/elmax 16 mm2 , terminal block (nut bolt type), make connectwell/ wago/elmax , 35mm2 , 95mm2 , 120mm2 , heavy duty copper lug (ring type) make dowells/havells/jaycee, , 16 mm2 , 50 mm2 , heavy duty copper thimble long barrel make dowells/havells, size: , 35 mm2 , 70 mm2 , 95 mm2 , heavy duty aluminium thimble long barrel, make dowells/havells/jaycee, size: , 35 mm2 , 50 mm2 , 70 mm2 , 120 mm2 , heavy duty copper thimble l shape, make dowells/havells/jaycee size: , 35mm2 , 50 mm2 , 70 mm2 , 95 mm2 , heavy duty copper ferrule, make dowells/havells/jaycee, size: , 35 mm2 , heavy duty aluminium ferrule, make dowells/havells/jaycee, size: , 70 mm , heavy duty copper lug (ring type) size: 10mm2 (3d10-10) od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 16mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 25mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 35mm2 od 22mm, id 10mm lump-sum , heavy duty copper lug (ring type) size: 50mm2 od 22mm, id 12mm lump-sum , single compression cable gland ss, make dowells/havells/jaycee/mic, size: , 16 mm2 , 19 mm2 , 22 mm2 , pvc cable gland make any standard size , 19 mm2 , 22 mm2 , double compression cable gland ss, make dowells/havells/jaycee/mic, size: , 25 mm2 , 28 mm2 , 38 mm2 , 45 mm2 , 50 mm2 , analog ct operated meter size 96x96 mm ae make , 150/5 , 100/5 , 30a direct meter , digital voltmeter meter, mode alp

CTN :40858579 Due date: 04 Jul, 202504 Jul, 2025 19.98 Lacs
Tender For 10/edc(s)/2025-26 - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 04 corners and 01 side for gate.

CTN :40858581 Due date: 04 Jul, 202504 Jul, 2025 19.98 Lacs
Tender For runningcontractfordepositworksunderedd-lambhua,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted

CTN :40858583 Due date: 04 Jul, 202504 Jul, 2025 19.98 Lacs
Tender For runningcontractfordepositworksunderedd-baldirai,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted

CTN :40858584 Due date: 04 Jul, 202504 Jul, 2025 19.98 Lacs
Tender For runningcontractfordepositworksunderedd-jaisinghpur,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grou

CTN :40858587 Due date: 04 Jul, 202504 Jul, 2025 24.69 Lacs
Tender For runningcontractfordepositworksunderedd,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 0

Central Government/Public Sector

CTN :40866555 Due date: 03 Jul, 202503 Jul, 2025 NA
Tender For multifunction meter with user programmable ct/pt ratio 5a or 1a ct input for lv or hv netw orks, input voltage 100-600v l-l auxiliary supply 12-60v ac/dc, display high brightness 3 line 4 digits led, size 96x96 mm, flush mount type, accuracy class 1.0 measurement and display parameters vaf, kw, kva r, kva, kwh, kvarh, kvah, pf, pa, mm, nc, thd run hours and on hours suitable for mounting in switch b oard cabinets of lhb power cars ,conforming to rdso spec.no.rdso/pe/spec/tl/0195-2019 (rev.0)or lat est accepted make rishabh/ socomec/siemens/ abb/ae / schnider /yokins/l&t only. [ warranty peri od: 30 months after the date of delivery ]

CTN :40835897 Due date: 02 Jul, 202502 Jul, 2025 1.30 Crore
Tender For e-procurement tender for electrical work first floor - supply & installation service lift db, supply & installation of earthing busbar, copper flexible wire 25 sqmm 1 run for earthing including cable laying and testing, digging 8 feet , 8 ft., gi pipe fixing, 2 x 2 copper plate fixing and 25 x 3 copper strips laying, funnel fixing, putting necessary charcoal and salt, 18 x 18 chamber mason work and miscellenous., indicator 22mm voltmeter lights 220 volt ac ryb (red, yellow, blue), vaf + pf ci 1.0 meter digital panel meter 1a /accuracy class 1 & ct coil, inside distribution board fixing, wiring and termination and lugs crimping and gland fixing and testing, main distribution board wiring and termination and lugs crimping and gland fixing and testing, led panel light fittings 2 x2, led panel light fittings 1 x1, earthing strip or wire, wide cable tray 600x150mm, light points 2 way 1 light for controlled by 2 switches, laying 1.5 sqmm wire 2 run fixing necessary pipe and 2 way switches 2 nos. and boxes plates., cable lugs and cabel gland 25sqmm, white casing pipe 100 x 50 mm, copper flexible cable 1.5sq x 3c including cable laying and testing, circuit 3 phase 6 sqmm + 4 run x 2.5 sqmm 1 run copper wires in 25mm dia fr pvc conduit, armoured cable(25sq x 3.5c) including cable laying and testing, copper flexible cable including cable laying and testing(25sq x 4c), copper flexible cable (16sq x 4c) including cable laying and testing, main circuit 2run x 10 sq.mm +1run x 4.0 sq.mm copper wires in 25mm dia fr pvc conduit, hearting circuit 2run x 4 sqmm + 1run x 2.5 sqmm copper wires in 25mm dia fr pvc conduit, lighting circuit 2run x 2.5 sqmm + 1run x 1.5 sqmm copper wires in 19mm dia fr pvc conduit, industrial switched sockets 63a, industrial switched sockets 32a, heating plug point 16a three pin switched sockets outlet box including providing 16a switched sockets & as required, plug point for 10a three pin switched sockets outlet box including providing 10a switched sockets & as required- - supply & installation, supply of light point controlled by a 10a, sp switch wall chipping, pipe fixing, switch plate fixing and testing- supply & installation
 Loading, Please wait...

Connect us via What's Up