Get complete information related to latest Electronic Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electronic Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electronic Meter Tenders.
Tender For special repairs to building no p 33 (ncc no 1 to 8 qtrs at or md accn at vnc and provn of electronicmeteres at different location of asc centre and college under ge central bangalore
Tender For tender for supply of negative sequence voltagesensing phase11 /33 kv frequency 200 hz p.no mer5590 or negative relay with sensitive broken conductor protection for 11kv & 3.3kv frequency 200hertz , digital clamp meter /tong tester 0-15-60-300 amp , flash light dia- 176 to 200 watt- 55 , type of battery smf halogen light hand held search light , fixed contact assy. cm5031 , kit kat fuse bk001075 , pin contatct main 1713401 , contactor power unit 3 pole 415/550v , 300-400 amp. ml-10 or equivalent , heavy duty glass fiber / frp highly insulated , self-supporting type ladder with platform size- 18 inch x 32 feet , 3 pole power contractor complete set , 500 amps coil voltage 415v/550v , or equivalent , 3 pole power contractor complete set , 2no + 2nc , 230 amps coil voltage 550v. ml 6 or equivalent , fixed contact 11kv h.t. switch , moving contact 11kv h.t. switch , epoxy resin cast type potential transformer for 11kv , 110volt 3 phase switch , epoxy resin cast type current transformer for 11kv switch , 300/150/5a
Tender For corrigendum : tender for supply of furniture, t&p and safety materials for utilization operation division vijaypur and rt division bagalkot coming under operation zone kptcl bagalkote conforming to our technical specifications, f.o.r.d at store/site including insurance and transportation and un-loading. - digital tong tester, ac clamp meter-200ma to 200a,accuracy rate - 0.01 to 0.1 a, lcr meter, display, phase sequence meter, measure the phase sequence (r,y,b) & open phase condition through led and buzzer., tool box with accessories-high quality tool box with tools like nut drivers, allen keys, screw driver set, heavy duty grip plier with nose plier, wire cutter, tester electrician wire stripper., multimeter,, tong tester, hack saw frames +b185, double end spanner 12 nos. per set, tube spanners 12 nos. per set, ring spanners 12 nos. per set, insulation tester (megger) 500 v, insulation tester (megger) 2.5 kv - 5 kv, frp telescopic discharge rod10 ft, high voltage detector, hand operated crimping tool 25 sqmm to 400 sqmm, frp wall extension ladder, open pulley capacity 2 ton, double pulleycapacity 3ton, ttubular telescopic tree pruner, bolt cutter - 24inches (rubber grip handle, hardened alloy steel jaws & center cut jaw configuration with max cutting capacity 12 mm, rubber hand gloves 11 kv, chain saw (motorised), extremely robust and long lasting chain saw. highly suitably for cutting firewood, thinning shrubs and bushes and shaping trees, telescopic earthing rod, sf6 gas filled in 25 kg cylinders (including non returnable carbon steel cylinders), sf6 gas filled in 50 kg cylinders (including non returnable carbon steel cylinders), xerox machine, polypropyline rope of 26 mm dia in kg, multimeterelectronic type, clamp meter, ac leakage clamp meter (ma) (dcm 10 a), head torch, hydraulic crimping tool manual with suitable dies for crimping lugs of size upto 400 sqmm set), electrical safety helmet attached with electronic induction tester, frp telescopic discharge rod 16 ft, safety belt, minimum 2 m rope length, protective eye wear for safety with integral hands free led lighting, hi visibility reflective rain wear, hi visibility reflective jacket, rubber hand gloves 33 kv, rubber hand gloves 15 kv, good quality heavy duty computer table, printer cum xerox cum scanner, office metal rack, good quality heavy duty steel almirah, good quality heavy duty computer chairs, good quality heavy duty s type full armed netted chairs medium back non rotatable & non foldable, branded plastic arm chairs, officers tables with draw, supply of good quality heavy duty office table, supply of good quality heavy duty metal rack, supply of good quality heavy duty office executive revolving chair ( high back with five legged ms fabricated revolving heavy guage base with twin wheel castors, with adjustable height & back tilt with fabric un-pholstered cushioned seat & mesh back rest, with adjustable armrest
Tender For corrigendum : supply of reverse power relay for main switch board , under voltage relay for main switch board , s/t coil 220v ac for air circuit breaker , under votage coil 220v ac for air circuit breaker , cluster contactor for acb , over load relay for avcat panel , phase failure relay 240vac for avcat system , timer 24v dc to 240 v ac 3sec to 6 sec delay for pc crane , timer 24v dc to 240 v ac o. 1 sec to 12 h timer for pc crane , single phase failure vspd1 single phase failure for ac panel , eta d1 electronicmeter for ac panel
Tender For corrigendum : supply of loading arm facility for ddd bowzer service : :-- electronics meter register peso approved , sply and instln of load arm top loading , digital control valve , pd meter peso approved , strainer cum air eliminator 50 mm
Tender For supply of 3 phase power measurment trainer kit , battery charger , battery for inverter , inverter , earth leakage circuit breaker, single phase , phase sequence indicator , phase sequence indicator , portable digital ammeter , portable digital energy meter , portable digital multimeter , portable digital wattmeter single phase , portable frequency meter , portable moving iron ammeter , portable standard energy meter , three phase lamp load , rs flip flop , t flip flop , multiplexer and demultiplexer trainer kit , parallel operation of alternator , dc series motor , single phase transformer , sepratly excited dc generator , tachometer , synchronous generator , portable digital earth tester , portable digital power factor meter three phase , digital power factor meter single phase , portable digital wattmeter three phase , portable lcr meter , digital flux meter , thermistor kit , lvdt trainer kit , digital clip on meter , analog megger , portable moving iron voltmeter , portable wattmeter , thermocouple trainer kit , digital breakdown voltage testers , inverse time over current relay induction type , earth leakage relay , fuse and mcb testing kit , inverse time over current static relay , display board different wires and cable , display board - different switches , digital megger , single phase power measurment kit , dol starter , electric drill kit , soldering gun kit , motor coil winding machine , dc shunt motor- shunt generator set , dc shunt motor -series generator set , dc motor alternator set , squirrel cage induction motor , slip ring induction motor , single phase capacitor start motor , three phase transformer , variac three phase , stroboscope , synchronous motor 3 phase , kirchhoffs law verification kit , portable digital power factor meter , rlc circuit trainer kit , study of self and mutual inductance measurment trainer kit , dc regulated power supplies , trainer board to study chopper , trainer board to study dual converter , trainer board to study cycloconverter , study of mosfet trainer kit , scr based lamp intensity control , 8085 microprocessor trainer kit , micrcontroller trainer kit , model cut section of refrigerator , cut section model of air conditioner , portable digital lux meter , resistance welding machine 3 phase power measurment trainer kit : 3 phase power measurment trainer kit by using ct (100-50-20-10/5a), pt(400-220/110v) and 3 phase wattmeter, battery charger : scr based automatic 12 v, ac input voltage 230 v, output dc voltage 0-12 v, 0-2 ampere rating provided with voltmeter, ammeter of suitable range, battery for inverter : tubullar lead acid battery min 180 ah, inverter : pure sine wave inverter of rating 1500 va or more, compatible with one 12 volts battery and noiseless operations. , earth leakage circuit breaker, single phase : single phase two pole 230v, 25a, 50hz, 30ma sensitivity, earth leakage circuit breaker, single phase : three phase four pole 400/415v, 25a, 50hz, 30ma sensitivity, phase sequence indicator : phase sequence indicator suitable for 50v-500v ac from 25-55hz, phase sequence indicator : rating 30 sec,500v,burden 15 va, voltage 50-500v, portable digital ammeter : 0-10 a ac, portable digital ammeter : 0-10 a dc, portable digital energy meter : 1-phase 2 wire, 240v, 5a, portable digital multimeter : 3. 5 digit, 1000v ac & dc, 0. 1 mv ac voltage //bid details2 / 72resolution, portable digital wattmeter single phase : digital wattmeter, 4. 5 digit led display, single phase, 230v, 50 hz,0-15a, portable frequency meter : digital, 4 digit led display frequency meter suitable for use on 230 v ac main supply range 20-99 hz, portable frequency meter : vibrating reed type 230 v, having 21 reed 40-60 hz. abs body, portable frequency meter : moving coil type, portable housed in phenolic moulded body with antiparallax mirror. scale and knife edge pointer, range 40-60 hz, 230 v, portable moving iron ammeter : 0-5 ampere ac ammeters portable moving iron, 150 mm uniform scale with
Tender For corrigendum : procurement of testing equipment for all power houses at thc sirmour - digital insulation testers (megger)range: 0-100/250/500/1000v, digital insulation testers (megger)range: 0-100/250/500/5000v, digital multimeterfeatures:dc & ac voltage; ac & dc current; continuity & resistance ; capacitance and inductance; checking of diodes/ transistors, single phase variable voltage autotransformers: details of single phase auto transformer 15a rating -input: 220v ac 10%; output: 0 to 270 volts.rating: 15 amps, three phase variable voltage autotransformers: details of three phase auto transformer 15a rating -input: 415v ac 10%; output: 0 to 500 volts, 3 phases.rating: 15 amps., tong tester cum multi meter (digital) (clamp on meter for ac measurements) specification for 0-1000a ac digital tong tester (clamp on meter) - current range: 0 to 1000 a (with settings of 1/10/20/40/100 a/500a/1000a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, tong tester cum multi meter (digital) (clamp on meter for dc measurements) specification for 0-300a dc digital tong tester (clamp on meter) - current range: 0 to 300a (with settings of 1/10/20/50/100 a/300a auto ranging) ; voltage range: 0 to 60/120/300 v dc.accuracy: 0.3% or better., tong tester cum multi meter (digital) (clamp on meter for ac/dc measurements) specification for 0-100a ac digital tong tester (clamp on meter) - current range: 0 to 100 a (with settings of 00-20ma/100ma/500ma/1a/10a/50a/100a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, digital phase sequence indicator: dial size: 96x96mm (minimum) ; working voltage: 50 to 500v ac; frequency: 25 to 60 cycles., digital earth resistance clamp meter with leakage current measurement
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi