Tender For bid to ras repair and maintenance of lift - service and maintenance of lift , rocket switch, door drive control seitch , limit switch, protective devices , break protective devices , pcb for position indicator signal pcb , phase reversal or single phase preventer , door or gate track rollers , 12 or 24 volt dc 10 or 12 pin no or nc contractor , led 5w emergency lamp , emergency alarm device , 12 volt 18ah maintenance free sealed battery , main controller trasformer primary 415 volts , floor relay oscillator switch , main contactor with coil, 60 amps , power contractor 32 amps with 24 or 28 volts , power contractor 32 amps with 02 no plus 2 nc , full length infrared sensor 64 beams , changer card of automatic rescue device , converter card of automatic rescue device , medfet card of automatic rescue device , rotary encoder for speed feedback , door motor with built-in rotary encoder
Tender For procurement of ics - ic: standard clock oscillators low power 1khz - 20mhz prec. oscillator, part no. ltc6900cs5 package- tsot-23-5, make: analog devices, ic: 74hc14d,653,schmitt trigger inverting smd,14 pin smd part no-74hc14d,653, make-nexperia, cpld - complex programmable logic devices programmable super fast hi density pld, pagage -tqfp-100 part no. lc4256v-5tn100i/lc4256v-75tn100-10i, make- lattice, ic: fixed ldo voltage regulator, 15v in, 1.2v dropout, 3.3v/800ma out, sot-223-4 part no. lm1117mpx-3.3/nopb, package- sot223-4, ma
Tender For sensors and measurement lab equipment - purchase of sensors & measurements laboratory, voltage, current and power measurement in single phase ac circuit digital power monitor- 10 asingle phase variac 0-240 v, 5 arheostat as load -500 , 5 avoltmeter 0-300 vammeter 0- 5 awattmeter analog 0-3000 welectrical panel & wiring , measurement of current in 3 phase circuit using single ammeter ammeter selector switch 440 v, 6 a 3 loading 5 a 3 phase variac 5 acurrent transformer 3 nos.ammeter 0-10 aelectrical panel, wiring & switches, measurement of resistance using wheatstone bridge necessary connecters provided to connect four arms range of measurement: 5 - 100k accuracy (min to max.): +0.2tolerance: +5%one digital meter provided to indicate the balance conditionsbuilt-in power supplynecessary patch chordsdecade resistance box, measurement of earth resistance by earth tester suitable connectors for 4 main arms and 2 adjacent armspotentiometer to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of inductance using anderson bridge suitable connectors for 4 main arms and 2 adjacent armspotentiometer provided to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of capacitance using schering bridge suitable connectors with 4 arms providedprovision to connect the unknown capacitance at one armtwo potentiometers provided to keep the bridge balance condition.inbuilt 1 khz oscillator and audio amplifier with speakermeasuring range: 0.001uf - 2.0ufsensitivity: +0.1uftolerance : +5%decade capacitance box , temperature measurement thermocouple trainer kit sensor type: thermocouplerange: upto 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning output: (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets, temperature measurement rtd trainer kit sensor type: rtd (pt100)range: up to 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning : (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets , behavior of proximity sensors proximity sensor of inductive provided to detect the metallic object. capacitive sensor provided to detect both metal and non-metal object.switching circuits provided to actuate the buzzer and relay.inbuilt regulated power supply.housed in a powder coated cabinet, linear variable differential transformer measurement trainer type: inductiverange: (0-25) mmexcitation: 4 khz, 1 v pp sine wavecalibrated range: (0-20) mm or + 10 mm/-10 mmsignal conditioner output: 0-5 vdc or +5/-5 vdcdisplay: 31/2 display digit ledmicrometer range: (0-25) mmtest points: 2 mm sockets, performance of ultrasonic and moisture sensors arduino uno board ultrasonic sensor to measure the distance.moisture sensor to measure the humiditylcd displayselector switch for display of sensor output.regulated power supplymount in a closed cabinet
Tender For supply of track oscillator f5/f7 frequency (s-25432-a1-a9) suitable for siemens make aws track mag net make : siemens. accepted make for siemens. (shop no.09) [ warranty period: 36 months after th e date of delivery ]
Tender For supply of ord case no 17 - card assy tx switch 1.2ghz , hmc 221 spdt switch , rx if module , diode tvs sm 14kesd33 , res fxd ch 680 5 percent 1w 200v , oscillator radio frequency tx lo module , comp acce hw cpu
Tender For supply of ord case 17 - card assy tx switch 1.2ghz , hmc 221 spdt switch , rx if module , diode tvs sm 14kesd33 , res fxd ch 680 5 percent 1w 200v , oscillator radio frequency tx lo module , comp acce hw cpu