Get complete information related to latest Electronic Rectifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electronic Rectifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electronic Rectifier Tenders.
Tender For erection of 01 nos 33kv rewan bay with supply of material, integration and remote gateway work at 220kv ss bangra under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For erection of 01 nos 33 kv birdha bay with supply of material, integration and remote gateway work at 220kv ss birdha under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : for procurment of 33 kv& 11kv outdoor oil cooled pole mounted type (combined ct-pt metering unites with meter box suitable for three phase four wire metering system
Tender For corrigendum : tender for supply of equipment material design erection testing commissioning for sop to ms shyam indus pvt ltd co prittam singh at vill baghni by prov 1104kv 25kva sstn aw 3ph lt line in vill baghni in e section bhadwar under esd hpsebl nurpur. t - 25 kva trsanformer, prov. distribution transformer (ordinary), 11/0.4 kv, 25 kva ., prov. steel tubular poles (9 m, working load > 200 kgf/m ) ., prov. muffs with concerete filling, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for incomer line, prov. ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov. x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov. transformer bed, belting & knee bracing, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, prov. x-arm [channel iron (100x50x6 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (35x35x5 mm), length : (460 ) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov. transformer lt distribution box and go switch fixing assembly, prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov. go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov. go ab switch unit (11kv, 400a, 25 ka ) tripple pole o/d type, prov. d.o fuse unit, prov. lighting arrester, 9 kv station class (porcelain type), prov. discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), prov. stay set complete, prov. stay wire (7/3.15 mm) (6.0 kg per stay set), prov. pipe earthing set, prov. lt distribution panel box with mccb(160a, 10ka, 4p, 1no) & sfu(32a, 5no, rewirable), prov. half clamp (m.s. flat 50x6 mm), prov. full clamps (m.s. flat 50x6 mm), prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. aluminium thimble, prov. copper thimble 35 amp, prov. danger plate, prov. barbed wire, prov. lt cable (3.5 core) 50 mm , prov. energy meter 3- , 4 wire ct operated static tri-vector meter with box(ct-100a), prov. aluminum paint., prov. 6/1/3.35, 50mm ., prov. construction of foundation of transformer, erection of 25 kva s/stn. i.e. digging of pit for pole & earthing two no. poles & 3 nos. for earth drilling of holes in x-arms, preparation of plateform str. members c.i., a.l. i.e. x-arms & k.b. set, errection of d/p, concreating of rcc muff errection of plateform, errection of x-arms, d.o., l.a., mccb, switch lt box, energy meter, errection of transformer, earthing connection to g.o. switch, transformer l.a. etc., errection of stay set, jumper, pipe earthing 3 nos set, l.t. cable, barbed wire and painting complete in all respect., transportation charges @10490/-, prov. transportation charges & mannual carriage of 25 kva pole mounted distribution s/stn. (line length 0.500km), erection of 3- ph. lt line, prov. aaac (7/3.15 50mm ) { neutral conductor including 1% (sag, jumpering and wastage}, prov. steel tubular poles (8 m, working load > 200 kgf/m )., prov. muffs with concerete filling, prov. shackle insulator with d-iron, prov. lt stay set i/c egg insulator., prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. stay wire, prov. g.i wire no 8swg, erection of 8 mtr. st pole single structure i.e. digging of pit, fixing of insulator, x-arms, k.b. set, top clamp, barbed wire, danger plate, drilling of holes and filling of pit + ramming complete in all respect., sagging of conductor i.e. laying, stringing and sagging & binding with insulator (single wire per km)., sagging of g.i i.e. laying, stringing and sagging & binding with insulator (single wire per km)., erection of stay
Tender For corrigendum : supply of safe carriage of pcc pole , safe carriage of st pole , cartage of line material , erection of pcc pole , erection of st pole , erection of doubel pcc pole , erection of stay set , erection of earthing rod , safe carriage of xlpe cable , erection of cable , erection of xlpe cable , erection of conductor , erection of ab cable , erection of tf , safe carriage of 11 kv pilfer proof metering cubicle , erection of 11 kv pilfer proof metering cubicle , guarding of 11 kv line , cutting and chopping of tree , providing and fixing of dp clamps , safe carriage of 11 kv ct pt , erection of 11 kv ct pt , safe carriage of lt distribution box , fencing of 250 kva tf , plinth of 250 kva tf , safe carriage and installation of 250 kva tf , providing and fixing of nut bolt , providing and fixing of holding clamps , safe carriage and installation of 11 kv pilfer proof cubical