Tender For supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply of suction pressure switch without capillary for lhb type ac coaches range 30-60/22-58 psi ps 27/45 bar, ts 30/85 degree centigrade, 6a 250 volt ac as per danfoss part no.acb-2ua 439 w, 061f7294 or alco part no.ps3-af3 hns, pcn 0713228 or from any approved vendor as per vendor directory of rdso for lhb rmpu's having similar specification with their part nos. [ warranty period: 30 months after the date of delivery ] ]
Tender For repairing of 200a mine line make switch type flp acb 550v, sl.no. 5419 controlling of ventilation fan switch, repairing of 200hp star delta starter flp acb prabhu make 550v, sl. no. 4517 ventilation fan starter at benidih u/g, phularitand colliery.
Tender For corrigendum : supply of 24v61c907 switch board : : - el3020b-acbsypm254-001 c-power acb 1000a , onboard spares obs , type testing , b and d not required , training charges not required
Tender For auction sale of pway scrap - released p-way mix scrap of ms consisting of tiebarr, rail 90r attached with tiebar, gtp, stretcher bar, st sleeper broken/converted, acb/bearing plate/lc road, steel key/dog spike/qtr pin, bolt off sizee, rail dolly, lc boom, angle, rail cut pc 90r, rail 75r, rail 41.25 r, rail 60r, rail 50r, xing off size, guard rail 90r, pcr off size, switch 60kg 1 in 12, rail 90r, fish plate, fish bolt, rail 60kg cut pic., tiebar/tiebar pannel u/s laying near snsn stn and rkh yard. at snsn station-336/8-14[tie bar-1907nos-8.601mt, rail 90r atteched with tiebar-118rm-4.632mt, gtp-10nos-0.350mt, stretcher bar -61nos-0.305mt, st sleeper broken/converted-268nos-6.432mt, acb/bearing plate/lc road-410nos-1.353mt, steel key/dog spike/qtr pin-2500 nos-0.460mt, bolt off size-100nos-0.080mt, rail dolly-6nos-0.300mt, lc boom-4nos-0.520mt, angle-390nos-0.620mt, rail cut pc 90r-323.37rm-12.694mt, rail 75r-110.45rm-3.486mt, rail 41.25r-80rm-1.391mt, rail 60r-43.65rm-1.104mt, rail 50r-59.90rm-1.263mt, xing off size-4nos-0.500mt, guard rail 90r-73.94rm-2.903mt, pcr off size-14nos-0.840mt, switch 60kg 1 in 12-2set-2.160mt, tongue rail off size-10nos-1.000mt, rail 90r-83.34rm-3.272mt, fish plate-14nos-0.120mt, fish bolt-10nos-0.009mt, rail 60kg cut pic.-35.70rm-2.068mt], rkh yard-368/7-12[tiebar/tiebar pannel-7700nos-34.727mt, pad lock-13nos-0.005mt]. [total weight- 91.200mt]. note-[1] item at snsn yard tiebar-1907 nos and at rkh yard tiebar/tiebar pannel-7700nos is in the form of tie bar fencing to be dismantled by purchaser during delivery. [2] after lifting of one station scrap material, lifting of other station material will be permitted. mode of delivery by actual weight.
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of
Tender For supply of switchgear items c c - acbs and their spares low tension acb conform to is2516 1965 part i sec and amended itable at 415 volts ac supply rating 400 630a 800a 1000a 1250a 1600a 2000a 3200a 4000a , mccb complete pole with only magnetic release with magnete thermal release breaking capacity 50 ka at 415 v 50 hz rating 10 a to 630 amp , starters dol star delta complete i dol. starters in steel enclosure motor rating ac2 duty 415 v 50hz 3 ph , starters dol star delta complete ii star delta starters fully automatic in sheet steel enclosure motor rating ac3 duty 415 v 50 hz 3 ph rating 12.5 hp 25 hp 35 hp 50 hp 75 hp 125 hp 250 hp , contractors and their spares suitable for operation on ac supply 50 c or s single phase three phase coil voltage 230 or 440 , lt switch fuse units and their spares switch fuses units on culrical switch board conform to is4047 1967 suitable for operation on ac supply 3 phase 415 volts 50 cs i in open execution , lt switch fuse units and their spares switch fuses units on culrical switch board conform to is4047 1967 suitable for operation on ac supply 3 phase 415 volts 50 cs i in sheet steel housing , lthrc fuses rating 2a to 630a ac supply 3 ph 415 v 40 cs having breaking capacity excluding 80 ka conforming to is2208 1967 i link type , lthrc fuses rating 2a to 630a ac supply 3 ph 415 v 40 cs having breaking capacity excluding 80 ka conforming to is2208 1967 ii dz type cartridge type