Get complete information related to latest Elemental Calcium Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Elemental Calcium Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Elemental Calcium Tenders.
Tender For supply of drugs and pharmaceuticals - d cfa re 49 desidustat 25mg tab , d cfa re 49 desidustat 50mg tab , d cfa re 49 lurasidone 40mg tab , d cfa re 49 hpylori kit , d cfa re 49 d cfa re 49 calcium syp containing elementalcalcium 250 mg elemntal magnesium , d cfa re 49 ocarbazepine 300mgml syp bott of 100ml , d cfa re 49 corn caps , d cfa re 49 bag rebreathing anti static rubber 500 ml , d cfa re 49 endotracheal tube s3 dot 5 with cuff , d cfa re 49 closed circuit for anaesthesia , d cfa re 49 et tube without cuff uncuffed size4 dot 0 , d cfa re 49 et tube without cuff size2 dot 5 , d cfa re 49 et tube without cuff size3 dot 0 , d cfa re 49 et tube without cuff size3 dot 5 , d cfa re 49 mallinckrodt micro laryngeal oral nasal tracheal tube cuffed size 5 dot 5 mm , d cfa re 49 endotracheal tube 4 size with cuff , d cfa re 49 lactode hmf sachet , d cfa re 49 feeding tube 6fr7fr , d cfa re 49 hhhfnc disposable high flow nasal cannula ssm , d cfa re 49 endotracheal tube 4 dot 5 size with cuff , d cfa re 49 paediatric catheter mount endotracheal , d cfa re 49 central venous triple lumen catheter 4fr , d cfa re 49 neonatal trochar 10fr12fr for chest drainage , d cfa re 49 atropine 0 dot 01 ophthalmic ointment , d cfa re 49 melatonin 5mg tab ) /bid number: gem/2025/b/6980657 * /dated: 09-12-2025 & & / bid document1 / 26
Tender For supply of acenocoumarol 1 mg tab , acenocoumarol 2 mg tab , tab bisoprolol 2 point 5 mg , frusemide 40 mg tab , tacrolimus 1 mg tab , anti phlebitis cream tube of 15g or 20g , cough lozenges tab , digoxin 0 point 25 mg tab , alprazolam 0 point 25 mg tab , rivaroxaban 10mg tab , antacid chewable containing dried aluminium hydroxide ip 250mg magnesium hydroxide nf 250mg methyl polysiloxane 50mg tab , cinnarazine 25mg tab , etophylline 115mg and theophylline 35mg in slow release form tab , pancreatic enzyme with a lipase content of 10000 to 20000 units cap , pancreatic enzymes supplement with a lipase content of 25000 unit or more cap , calcium carbonate syp elementalcalcium 125 mg per 5 ml 200ml bott , mupirocin 2 percent oint tube of 5 gm , pantoprazole 40mg plus domperidone 30mg tab sr
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque