Web Analytics Made Easy - StatCounter

Elisa Test Kit Tenders

Get complete information related to latest Elisa Test Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Elisa Test Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Elisa Test Kit Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45743518 Due date: 21 Jul, 202621 Jul, 2026 37.66 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)

State Government

CTN :45743537 Due date: 21 Jul, 202621 Jul, 2026 10.72 Lacs
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

corporations/Associations/Others

CTN :45742445 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of anti-hav elisa test kits (v2) (q2) , anti-hev elisa test kits (v2) (q2)

corporations/Associations/Others

CTN :45742468 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of dengue elisa test kit (q2)

corporations/Associations/Others

CTN :45742486 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of elisa test kits (v2) (q2)

corporations/Associations/Others

CTN :45742497 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of elisa test kits (v2) (q2)

CTN :45577318 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : e –tender for rate contract of consumable items to chhattisgarh medical services corporation ltd rna extraction for covid-19 (manual) vtm kit, salt testing kit alkaline paper electrophoresis, test kit, rapid plasma (rpr) for syphilis testing gluco test strip (2300 ordinary lancet, 2 gluco, meters having 4 pen devices preloaded with depth setting to be supplied free of cost with 2000 strips), rpr kit and syphilis vaccine carrier box rapid plasma regain (rpr) test kit, hepatitis b virus anti hbs elisa quantitative test kit ., mumps virus igm elisa qualitative test kit rubella virus igm elisa qualitative test kit vericella zoster virus-i igm elisa qualitative test kit, cytomegalo virus igm elisa qualitative test kit ., hsv (i and amp; ii) virus igm elisa qualitative test kit japanese encephalitis, virus igm elisa qualitative test kit measles virus igm qualitative, elisa test kit anti hev igm elisa qualitative test kit, rt-pcr kit with h1n1 assay set chikungunya virus igm, elisa qualitative i rota virus antigen elisa test kit, hcv pcr assay kit ready-to-use molecular detection kit for realtime, pcr based detection of hepatitis c virus dna. all necessary reagents optimized for reliable, hcv dna detection and quantitation, including genotypes a– h for in vitro diagnostic use`, hepatitis c virus anti hcv elisa quantitative test kit, hepatities c virustotal ab elisa test kit, anti hav igm elisa qualitative test kit, hbv kit ready-to-use molecular detection kit for real-time pcr based detection of hepatitis b virus dna. all necessary reagents optimized for reliable hbv dna detection and quantitation, including genotypes a–h for in vitro diagnostic use`, dna mini kit the kit should provide silicamembrane- based nucleic acid purification from tissues, swabs, csf, blood, body fluids, or washed cells from urine.the kit should not be based on mechanical homogenization of tissues, rather it should be based on enzymatic lysis of tissues., antibody (igm, igg) based rapid test for diagnosis of covid-19

CTN :45732553 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For restoration of rain damages to wss uba in gp nagdhar tehsil sadar distt. mandi (hp). (sh:- construction of rcc intake chamber and hiring of hy-draulic excavtor & laying, jointing & testing of gms pipe 40 mm dia = 36 rmt. for cleaning of debries from source.)
 Loading, Please wait...

Connect us via What's Up