Web Analytics Made Easy - StatCounter

Emergency Position Indicating Radio Beacon Tenders

Get complete information related to latest Emergency Position Indicating Radio Beacon Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Emergency Position Indicating Radio Beacon Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Emergency Position Indicating Radio Beacon Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39964671 Due date: 20 May, 202520 May, 2025 NA
Tender For corrigendum : tender for supply of vao card , vrtu console signal splitter (2 pole relay) , vdmc , marine isolator , battery pack for ups , ruggedized , 2.4kw dc ups power unit , rugged panel mount 2 in trackball , lonisation smoke detector , optical smoke detector , isolator base , i.s lonisation smoke detector , i.s optical smoke detector , addressable base for is type sensors , magnetron transceiver , modulator 25 kw transceiver , power supply pcb , trigger pcb transciver

Central Government/Public Sector

CTN :40210703 Due date: 07 May, 202507 May, 2025 NA
Tender For supply of 2 position signal knob (red) make: recom and model: c10p226b. (10a ac cam s witch 2 pole 2 way no off 2 position/switches without ip and with red knob, size-48x48mm). ]

CTN :40187616 Due date: 22 May, 202522 May, 2025 NA
Tender For tender for supply of relay insulation 24240 acdc 1no , power supply ip380vacop24vdc 10 amp , temp converter , signal isolator 1 in 1 out , mcb 2 polec curve 6 amp , mcb 2 pole c curve 10 amp , mcb 2 pole c curve 02 amp , mcb 3 pole c curve 02 amp , mcb 1 pole c curve 04 amp , mcb 2 pole c curve 04 amp , o ring kit , memory card 6es79548le030aa0 , ai module 6e575317kf000ab0 , front connector 6es75921amoo0xb0 , di module , plate door interlock , terminal shroud , terminal block 280519 , terminal block 20023201 , multipin connector ms3102r2214s , door limit switch 3se5122oya003se5000ae01 , terminal fuse with indication 281611281541 24v dc , fuse glass , pilot lamp red xb7ev04bpn , backpane for plc 6es75901ab600aa0 , terminal block 283901 , panel light mtl2835150 , spring compression , valve check , spring compression , rotor pair , retainer check valve , shim , ring retaining , bearing cylindrical roller , locknut , plug pipe1214 nptf w375 orifice , bearing angular contact ball , sleeve male distance , lamp 24vdc white , push button 1 noblue , relay 4co 24vdc , switch selector 230 vac2 amp , programmable logic control , thermister relay , selector switch key , lamp 24vdc green , relay base , relay 4co 110v ac , power indicator ip420 m a , handle rotary , contact block , transformer 380115vac630va , hmi , filter drier replacement core , bearing spacer , chock mount , motor starter , relay , shaft seal sea water pump , cable gland vg88773 , coolant water pump with motor , thermometer , shaft seal chilled water pump , bearing cap , valve plate set , set of gaskets , shaft seal complete , gasket for capacitor covers , lamp , discharge line thermometer 0120 c , defrosting control sensor , pin dowel special , contact auxiliary1no+1nc , contactor3p 440 vac 50 amp , key square 12x12x312 , rod indicator , retainer check valve , switch isolator63 amp , motor protection , o ring & gasket kit , siematic hmi kp 400comfort panel , cpu 313c central assembly , motor starter , o ring , o ring , power supply unit 380 vac24vdc 10a , pressure relay , valve with solenoid drive 115v , sea water regulator v46 bc 96 , shut off valve , motor couplingturboflexend middle pad msgill package , shut off valve hdlk15 , shrader valve , flexible metal hose , oil seperator , solenoid valve on liquid pipeline , sea water pressure switch typ , delivery line thermometer 0120 c , delivery pressure gauge , oil flow rate relay , cooling water regulator , resistance thermometer , tex2 cutoff valve r22 58x12mm , delivery side pressure guage , suction side pressure guage , flow switch , safety high and low pressure cutout , thermostat rt 11 , load break switch & fus , load break switch & fus , stop valve , stop valve , stop valve , inset for valve with ratchet , switch , auxiliary switch , auxiliary switch , air contactor , fuse 500v , oil protection control diff pres cntr with bntime de swi , timing relay , fuse switch , switch , freeze protection thermostat , resistance thermometer , thermoregulating valve , vbelt 5x1600la , nipple with coupling , selector switch , pilot lamt white , lamp holder , housingseal , sea water pump , impeller , auxiliary contactor , heat exchanger , shut off valve , discharge temperature switch 0175135

CTN :38754292 Due date: 03 May, 202503 May, 2025 35.0 Thousand
Tender For bid to ras corrigendum : supply of torsion bar , sleeve , bolt sperical , 12 pole socket , light convoy , blackout stop light , field coil assy , red reflector , turn signal light , split pin

CTN :39884949 Due date: 03 May, 202503 May, 2025 28.0 Thousand
Tender For bid to ras supply of bearing hub , turn signal light , light convoy , bracket stop light , red reflector , steel wire , pole screw , bush , field coil assy , solenoid switch , combination switch

CTN :39885238 Due date: 02 May, 202502 May, 2025 NA
Tender For bid to ras supply of emergency position-indicating radio beacon (epirb)

CTN :39897293 Due date: 30 Apr, 202530 Apr, 2025 NA
Tender For bid to ras tender for supply of lv7/stln5330-002272gasket for feed pump (p-1300317) , lv7/stlnf-2630200eng mtg pad p/3991 , lv7/stlnx-4109800rope wire steel 8 mm dia 8 mtrs long , lv7/stln3110-72-0000505bearing tapered roller , lv7/stlnf0214410rear hub bearing , lv7/stlnx-3943800(m-250990)spring brake chamber , lv7/stlnbon00678driver cabin door lock left , lv7/stln2510-007918front/rear spring assy , lv7/stlnp-4801633pto idler shaft , lv7/stln2590-72-0475394bowl oil filter element , lv7/stln2520-012650drum clutch power-take off , lv7/stlnp-3108951center bolt kit frt & rear spring p/485 , lv7/stln5120-423823adaptor torque wrench , lv7/stln(vf)b-2594502tie rod assy , lv7/stln(vf)14670303084 arvane pump , lv7/stln(vf)2460230774 arroller ring , lv7/stln(vf)24601400214 arcross disc , lv7/stln(vf)2930-72-0471202radiator with shroud , lv7/stln(vf)14661116914 arcam plate , lv7/stln(vf)2530-72-0472270brake shoe , lv7/stln(vf)1467135270positioner assy , lv7/stln(vf)14683760174 ardistributor head , lv7/t-815133-335-686-809sealing ring 16x20 is 1375-74-a1 , lv7/t-815273-221-951-854sealing ring , lv7/t-815133-335-686-204sealing ring 14x18 is 3175-74 al. , lv7/t-815130-954-160-994glass sealing 535 mm , lv7/t-815130-050-990-724sheet coller , lv7/t-815442-953-180-134hose dia 5x8 960 mm , lv7/t-815311-214-425-084toothed washer-8 4 csn 02 1744.05 , lv7/t-815443-925-930-019wiper rubber blade , lv7/t-815441-954-480-524tie rod clamp , lv7/t-815130-051-190-434packing piece , lv7/t-815133-330-072-000hose js 8x600-1111 on 635412.02 , lv7/t-815130-054-391-164threadle lining , lv7/t-815130-050-110-894shift , lv7/t-815442-954-161-004gasket 420 mm , lv7/t-815131-858-019-032bushing for socket , lv7/t-815109-419-555-220sealing ring 48x55 is 3175-74a1 , lv7/t-815131-858-021-022pin coupler , lv7/t-815442-079-050-134light switch , lv7/t-815443-854-151-001exhaust brake switch , lv7/t-815121-223-352-240bulb 24 v/21 w ba 15s , lv7/t-815443-224-862-914heater glow plug two-pole , lv7/t-815130-076-855-984line to inflation system , lv7/t-815442-053-621-404reduction coupling , lv7/t-815443-317-049-109brake circuit signal lamp , lv7/t-815443-855-003-006fuse box , lv7/t-815130-954-161-214sealing rh 415 mm

Central Government And Public Sector

CTN :39489492 Due date: 05 May, 202505 May, 2025 19.46 Lacs
Tender For corrigendum : tender for supply of signal condit module , scm009a15.bhel , signal interface module , bhel , sim029l08 , pulse input module pim2000 , make bhel , digital input module dim2001 , bhel , digital output module dom2000 , make bhel , analog output module , aom2000 , make bhel , bus terminator module btm2000 , make bhel , analog input module , aim2000 , bhel , pulse relay module prm 054d11 bhel , relay interface module rim034d11 , bhel , fdr disp keyboard , gfc-kbd or disp bh , bhel , 24 pole tacho generator , bhel , calibration probe , bhel , bhelfeed , retro refl tape , bhel , gravimetric feeder , calibration kit for grav.fdr , bhel , power supply module dnr60us12 , bhel , power supply module dnr120us12 , bhel , disch plug switch assy , 36 feeder , bhel , coal on belt switch assy , 36 feeder , bhel

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
 Loading, Please wait...

Connect us via What's Up