Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoringsystem, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For supply of machine, equipment and others - list of machine and equipments, laproscopic hd camera brand - karl storz/conmed/olympustechnical specificationresolution: 1920x1200 pixes / 1900x1000 pixescable length: 300 cm, ultrasonic harmonic scalpelbrand - johnsontechnical specificationdimensions: (hxwxd) 5.3" 14.5"x15.2" voltage: 100-240 vac frequency: 50/60 hz rated current: 3 amp , ultrasonic harmonic scalpelbrand - valley labtechnical specification macrobipolar/bipolar: 473 khz sinusoid, 100% duty cycle. seal: 473 khz sinusoid pulsed , hand instruments for laproscopy brand- karl storz/ olympustechnical specification i) veress needle: it should be with spring action blunt style -12 cm: 1 no 10 cm: 1 no 8 cm: 1 no ii) trocar and cannula: 10 mm: 2 nos 7 mm: 1 no. 5 mm 6 nos it should consists of trocar, cannula with insufflation and multifunctional valve and must have pyramidal tip. iii) reducer/reduction sleeve 5 mm. 1 no iv) telescopes: 10 mm- 0 - 1 nos -30 - 1 nos 5 mm-30 1 nos rigid rod lens system provides good resolution and the better dept perception. it should have uniform image brightness and autoclavable. the 300 forward oblique angle and permits for greater latitude for viewing underlying areas under difficult anatomical conditions. v) suction cannula: 10 mm - 1 no 5 mm -1 nos vi) laparoscopic scissors: curved (monopolar metzenbaum dissector 5mm diameter): 1 nosstraight (bipolar): 1 nosperitoneal scissor: 1 nosvii) unipolar forceps (hook & spatula): 2 nos viii) bipolar forceps : 2 nos ix) atraumatic forceps: maryland dissector forceps: : 2 nos. fenestrated forceps: : 2 nos. x) needle holder (flat jaw) with handle : 2nos xi) monopolar cable (reusable):1 nos. xii) bipolar cable (reusable): 1 nosxiii) allis (double row of teeth) grasper: 1 nos xiv) aspiration needle: 1 nos. xv) reducer/ reduction sleeve (5mm): 1 nos xvi) grasping forceps (toothed & rachet 5mm): 2 nos xvii) laparoscopic knot pusher: 1 nos xviii) clip applicator (reusable): 5mm -: 1 nos : 10 mm: ino xix) uterine manipulator: 1 nos xx) clips( medium & large) xxi) drilling needle: 1 nosxxii) infiltration needle: 1 nos xxiii) biopsy forceps (toothed punch biopsy): 1 nos xxiv) myoma fixation screw: 2 nos xxv) tissue morcellator with base unit & accessories: 1 nos , dual wavelenght laserbrand- zeisstechnical specification laser type: diode, semiconductor wavelength : 1470nm+635nm max power: 15 watts/1470nm+5mv/635 aiming beam : 635nm/1, 4mw max or 515nm/2, 5mw max operation mode : continuous or modulated pulsed time : 0.05ms-1000ms beam delivery : sma905 connector optic fiber compatible : optic fibers having a core from 200um to 1000um, na=0.22~0.48 beam emission initiation : footswitch controller :microprocessor display : 10.1" ips with touch panel medical approved cooling : internal, air and thermoelectric cooling power supply of the laser: dc 24v/8.33a from the separate ac power supply of ac adapter : single phase 100-240va; 50-60hz, max 90w ac adapter dc 24v/8.33a medical approved laser dimensions: 27cm*24,5cm x 9cm laser weight: 2.75kg laser case dimensions : 53cm x 38cm x 23cm weight of laser with cases : 9kg environmental conditions during work : from +10 to 24 c degree, relative humidity from 30% up to 60% cass of medical device iib laser safety class 4 electric safety class i type b housing protection degree ip20b , hd camera setbrand- karl storz/ olympustechnical specification (i) hopkinsa forward-oblique telescope 30a, diameter 4 mm, length 30 cm, a utoclavable, fiber optic light transmission incorporated, color code ed : 1 nos(ii) telecam c3 : 1 nos(iii) image1 st hx one-chip full hd camera head, 50/60 hz, fixed focus, prog ressive scan, soakable, gas-and plasmasterilizable, focal length f = 16 mm, 2 freely programmable camera head buttons, for use with image1 x-link tc301, tele pack + and tp101 : 1 nos(iv) medical grade surgical monitor - fhd : 1nos(v) cold light fountain power led 175 scb, with integrated karl storz-scb, high-perfo