Web Analytics Made Easy - StatCounter

Empanel Tenders

Get complete information related to latest Empanel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Empanel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Empanel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :36845147 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of ce010280019: fire alarm panel for fda in lhs, qty: 1 no , st050070109, addressable multi criterial detectors intelligent analog capable of giving exact locati , st050070108, addressable smoke detectors intelligent analog capable of giving exact location of , st050070107, addressable heat detectors intelligent analog capable of giving exact location of fire, , st050070106, addressable manual call points-indoor type, qty: 102 nos , st050070105, ir flame detector with addressable module, qty: 18 nos , st050070104, addressable hooter, qty: 40 nos , st050070103, interface unit (monitoring module) , qty: 96 nos , st050070102, interface unit (control output module) , qty: 150 nos , st050070117, response indicators, qty: 12 nos , st050070100, sounder strobe for fire protection panel, qty: 36 nos , st050070111, emergency exit & warming sign, qty: 15 nos , st050070112, junction boxes, qty: 72 nos , material code: st050070113, linear heat sensing cables, qty: 5000 metres , st050070046, dvcp(deluge valve control panel) box for fdaamvwss, qty: 24 nos , st060300228, pressure switch: ds-802/m 0.5-15 bar nr: 658015, hagglunds pn: 577 8810-012, rexroth pn: r9 , st060290229, pressure gauge 0-16 bar, glycerine filled, 1/2 inch npt m, qty: 80 nos , st050070114, solenoid valve, qty: 40 nos , st050070115, 24v dc power supply, qty: 30 nos , st050070116, fire alarm repeater panel, qty: 1 no , sc440020046, 1100v grade 3 core 1.5 sq. mm frls cable, qty: 12000 metres , sc440020103, 1100v grade 2 core 1.5 sq. mm frls cable qty: 7000 metres

CTN :40906107 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For request for empanelment (rfe) to empanel vendors for implementing it solutions for niacl

Central Government/Public Sector

CTN :40904413 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For electrification work in connection with provision of one common room for datalogger, eld, fuse alarm system monitoring and storing s&t critical maintenance spares at various stations/automatic huts on bsl division.

CTN :40324015 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For corrigendum : computerised control, alarm and monitoring system (ccams) for orv project yard 3041

Central Government And Public Sector

CTN :40873700 Due date: 03 Jul, 202503 Jul, 2025 NA
Tender For insulation monitoring relay 110 volt ac, range 50 v to 200 v ac insulation measuring ra nge 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 hz having fault memory test and reset b utton and alarm lead as per rcf specification edts-073 rev d amend 3. as per drg.no. nil as per spe cn. rcf specification edts-073 rev d amend 3 [ warranty period: 30 months after the date of deliv ery ]

CTN :40865390 Due date: 17 Jul, 202517 Jul, 2025 77.00 Lacs
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi

Central Government/Public Sector

CTN :40848015 Due date: 09 Jul, 202509 Jul, 2025 NA
Tender For insulation monitoring relay rated 415 volts, 3 phase neutral isolated voltage - range 0 to 500 volts ac, insulation measuring range 0 to 500 volt ac, insulation measuring range 10 kilo ohm to 150 kilo ohm, control supply 230 volts %b1 10%, 50 hz having fault me mory test reset button and alarm lead as per rdso specification no rdso/pe/spec/0192 -2018 (r ev-1). make: m/s bender- ir 470ly-21a or equivalent of m/s abb or m/s contrel or m/s woka or m/s-schneider or m/s-siemens or m/s-dold. (to be supplied with oem's proof of purchase along with test certificate.) [ warranty period: 30 months after the date of delivery ]

State Government

CTN :40846282 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For comprehensive preventive and breakdown maintenance cum round the clock monitoring of fire detection and alarm systems at different building within the campus of calcutta pavlov hospital, kolkata, for one year

corporations/Associations/Others

CTN :40566432 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For corrigendum : supply of safety items for hem equipment - 1600565713 operator fatigue system with recording , 1600565714 rear vision system with recording , 1600565715 seat belt reminder audiovisual indicator , 1600565716 autodipper system , 1600565717 smart rearview alarm , 1600566258 proximity system radar based system , 1600566259 dumpbody lift indicator with voice alert , 1600198760 camera monitoring system 360 degree

CTN :39430591 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For corrigendum : procurement of main switch board spares - tender for supply of indicating lamp -colour red , input voltage 240v ac , 50hz , led , sea water pressure switch , dc mcb 4a , dc mcb 10a , 100a mccb , mccb 20a , mccb 80a , mccb 160a , relay 240 vac mno 2no 2nc contact , mccb for msb 400 amps , hcos , 380v , 3phase , 50 hz , 300a , cpu with 28 step memory , cc link for master slave , 32 channel do , connector for rtd card , 4 channel ao module , 32 channel di , 24x30 mm yellow indicator , 24x30mm green-momentary 1 c o pb , side hydrobar 0.4 bar 2m cable , automatic emergency lantern , 24v dc buzzer , hrc fuse base & carrier with 32a fuse link , em log microcontroller card , mccb 400a-3p with aux contacts , mcb 2 pole 4a type c 10 ka , 415-240v , 750va control transformer , mccb dm100 25a , indication lamp red , 415v , synchroscope , power terminals cstsn4 , undervoltage relay uvtd1 3 phase , insulation monitoring relay t3200-00 , under-over current relay ccsd2 1phase , minitec , a1d1 wb on delay timer , mn0 aux.contactor 4no with 240v ac coil , rs232 to rs422-485 isoloated converter , motor protection relay , microprocessor based , mn 2 - 24 a to 32 a overload relay , mn 2 - 13 a to 19 a overload relay , 125a hcos , ethernet switch 8 port , type rs30-08020606edhe , fiber sfp module , vme backplane , incom sys 4 watt water tight horn loudspeaker pan 9601 , aldis lamp , 20a hrc fuse base and carrier with 10a fuse link , mast head light white , side light red , side light green , anchor light white , lamp 220v-65w , 16a switches 21066 , 6-16a socket 30828 , eot- push button type tx-rx , eot-push button type tx-rx , eot-rotary switch type receiver , led lamp green 12v dc , 50a , 1 way mcb , 2p , 24 v dc fan with filter module , rtd to current converter-dat 4631b , proximity switch 0-150 rpm , 2 core 1.5 sq.mm. fire proof cable , multi core 1.5 sq.mm. fire proof cable , magnetic float switch-tds , magnetic float switch-tilt , thermocouple k type 0-600 deg c simplex , frequency to current-voltage converter , pressure transmitter 0-2.5 bar mbs 33 m , pressure transmitter 0-6 bar-emp 2 , pressure trasmitter 0-6 bar-mbs 33m , pressure switch 0-24 bar-mbc 5100 , pressure switch 0-40 bar-mbc 5100 , differential pressure transmitter 0-2.5 , differential pressure transmitter 0-3.2 , differential pressure transmitter 0-4 b , exide battery 42ah , 12v , fan with filter , control panel , lon-network no mudules , detector loop module 1 loop 127 units rmax-50 m 140ma , panel alarm output module , 4x24vdc-1a sounders , control output module , 8xopen collector no , max 100ma , modbus com.module , slave rs422-485 , serial output interface card , rs-232-422 or 485 , multi sensor head , smoke-heat , sv , multi sensor head , smoke-heat , ip44d conduit box , battery fastening strap , pt 100 0-100oc-150mm , pt 100 0-120oc-400mm , toothed belt disk , toothed belt disk 6 , power factor-3ph , 3 wire , 1element415vac , size 96x96 , transformer 415-230v , 500va , 50hz , mcb 10a tp , mcb 16a tp , mcb 40a tp , mcb 50a tp , mcb 63a tp , hcos 50a with out enclosure , keyboard , processor , propulsion control pcb unio , display , flot level switch , changeover switch co3-250 , mccb , 3p , dl-100 , 16a , mccb , 3p , dl-100 , 25a , mccb , 3p , dl-100 , 40a , lamp 415v , led , green , control transformer , 415-230v , 100va
 Loading, Please wait...

Connect us via What's Up