CTN :44705174
20 Apr, 2026
2.00 Crore
Tender For procurement of 67 types of cardiac stents and consumables for inhs kalyani through pa - conclusion of price agreement for 67 in number items for cardiac stents, pacemakers, etc for a period of two years at inhs kalyani - drugs and consumables, combo device (implantable cardiovertor defibrillator + biventricular device) - complete with accessories, dual chambetr automatic implantable cardiovertor defibrillator - complete with accessories, angiography surgical disposable table drapes sterile, angioplasty kit (insertion tool, y adaptor and torque device), coronary guide wire - nitinol core - hydrophilic coated (floppy, moderate or extra support), coronary guide wire - stainless steel core - hydrophilic coated (floppyt, moderate or extra support), ecg electrodes (disposable), high pressure 3 port manifold, inflation device (indeflator) kit for angioplasty, judkins left angiography catheter - assorted sizes, judkins right angiography catheter - assorted sizes, syringe leur lock polycarbonate construction for use with sclerosants etc, 10 ml, permanent pacemaker dddr, complete with temporary pacing lead, permanent pacemaker vvir, complete with temporary pacing lead, ptca balloon dilation catheter - rapid exchange - assorted sizes, ptca balloon dilation catheter - rapid exchange, high pressure (extended range) - assorted sizes, ptca guide catheter - judkins - assorted sizes, ptca guide catheter - speciality curves - assorted shapes and sizes, ptfe angiography guide wire 0.035 x 150 cm j tip, ptfe angiography guide wire 0.035 x 260cm extra stiff, ptfe angiography guide wire 0.035 x 260cm j tip, radial hardware, rapid exchange cutting balloon - assorted sizes, rapid exchange thrombus aspiration catheter system, special curve angiography cathters (amplatz, multi-purpose, ntr etc) assorted shapes and sizes, temporary bipolar pacing catheter - assorted sizes, 5f/6f radial angiography catheter, 6f long sheath 55 cm, 6f radial sheath, 7f long sheath 55 cm, angioseal, c-arm cover (2 pcs for top and bottom) compatible with ge igs 320 cathlab system, c-arm cover (3 pcs for complete "c") compatible with ge igs 320 cathlab system, coronary angioplasty kit, coronary balloon with flexible microsurgical blades, coronary guidewire silicon coating over the spring coil with extra support, coronary guidewire slip-coat (coating over polymer jacket) with excellent lubricity and trackability in tortuous vessels (tapred tip), coronary guidewire slip-coat (coating over the spring coil) with greater tip flexibility and support, coronary micro catheter system, dedicated kit for radial angiography, drug elluting coronary balloon system (paclitaxel elluting), ecg paper a4 size for tmt test compatible with moratara x-scribe system and hp class="text-red-selected">laserjet 103a (pa
ck of 500), everolimus drug eluting
cobalt
chromium
cornary stent-assorted sizes, everolimus eluting balloon mounted platinum
chromium
coronary stent system - assorted sizes, everolimus eluting
cobalt
chromium
coronary stent system for long lesion upto 48mm, femoral sheath 6f 11
cm, femoral sheath 7f/8f/10f 11
cm, guideliner (5f/6f/7f), high pressure
cto balloon with low
crossing profile (diameter 0.85mm) assorted sizes, hp
class="text-red-sele
cted">laser toner
cartridge for hp
class="text-red-sele
cted">laser 103a, i
cd single
chamber mri, low tip profile mi
cro
catheter with torque
control, mi
cro pun
cture set, post sterilization
cardiology gown with sterile towel, semi
complaint pt
ca balloon
catheter with
corrugated surfa
ce and low profile wig shape design (sizes 1.0 mm to 1.5 mm), sirolimus drug eluting
cobalt
chromium biodegradable polymer
coated with hybrid open
cell, double helix stent assorted sizes, sirolimus eluting
coronary balloon system, surgi
cal angiography drapes with open for radial and femoral a
ccess, terumo angiography guide wire 0.035 x 150
cm j tip, ultra high pressure n
c balloon upto 45 bars dual layer with lesion entry profile of 0.16 and
crossing profile of 0.026, zotarolimus eluting balloon expandable
cobalt alloy
coronary stent system with
con