Get complete information related to latest Energizer System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Energizer System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Energizer System Tenders.
Tender For corrigendum : supply of 0.5 ltr. single filter part no f7482200 , banjo bolt for fuel pipes part no f3131415 , washers for banjo bolt part no f4930430 , s a of fuel pipe-feed pump to filter part no b7008903 , return hose 3 8 inch- 5.5 mtrs. part no f1930260 , s a of fuel pipe filter to fip part no b7008903 , coil type filter element part no p1301540 , sealing ring part no p1301807 , oil filter part no b7015403 , slinger part no f1134350 , seal sub assy. coolant pump part no b7016003 , s a of vane coolant pump part no b7016004 , v belt part no f0330950 , alternator part no f7482000 , starter motor12v-lucas tvs part no f7481900 , inn. cartridge comp. part no 9095 1011 01 , air filter element part no 9095 1009 01 , strainer part no 1612 0604 00 , flex. tube-tank to lift pump part no 0574 9712 37 , engine oil pressure gauge part no 0873 0608 02 , air pressure gauge part no 1619 5268 00 , comp. temp. gauge part no 9095 5771 00 , hour meter part no 9095 6906 00 , key switch ignition part no 9095 6907 00 , copper tube part no 9095 6898 00 , button-stop cable part no 9718 2168 00 , stop cable part no 9095 7202 00 , temperature gauge water part no 1619 1637 00 , battery -12 v - 85 ah part no 9095 5540 00 , battery cable part no 1614 0866 02 , battery cable part no 1614 0866 01 , hose clip part no 0347 6113 00 , hose xa 140 part no 9095 7178 04 , hose xa 140 part no 9095 7178 03 , hose xa 140 part no 9095 7178 05 , separator element oil part no 9095 7345 00 , oil filter part no 1613 6105 00 , flexible hose part no 9095 7059 00 ) /bid number : gem/2026/b/7570394 * /dated: 21-05-2026 & & / bid document 1 / 31
Tender For supply of all inclusive comprehensive maintenance including periodical servicing of following capacity engine alternator sets installed at various te admin bldgs bts sites etc , providing replacement of following faulty items in the existing dea set essential for the smooth operation of dg set complete with installation testing and commissioning all as required , engine safety control box with audiovisual arrangement alongwith wiring to make operational the above item , 12 volt 10 amp smps type battery charger ic transformer, rectifier unit and filter circuit etc , digital ac voltmeter 0 to 415v , avr make national or ss make
Tender For repair, maintenance and overhauling of dg sets and its engine, alternator, control and protection panels, avr, battery and battery charger, fuel system, lubrication system, cooling system, exhaust system, accoustic enclousure, cabling, earthing and a
Tender For supply of 5 kva diesel generator set specification: diesel generator set 5kva, single phase, portable type with wheel, no. of cylinder : 1, no. of strokes: 4, rated engine power: 110 % of the required power at stp, capacity of engine (cc): 428 or higher, air cooled, mechanical governor, class of governor a2 or better, speed 1500 rpm, 50 hz, fuel: hsd, fuel tank capacity : 15ltr, direct injection fuel system, electric start, battery 35 ah or higher, starting voltage 12v, brushless alternator, alternator voltage 230v, manual control panel. compliance to cpcb ii guidelines of emission & noise required. type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb required. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 5 kva diesel generator set specification: diesel generator set 5 kva, single phase, portable type with wheel, no. of cylinder : 1, no. of strokes: 4, rated engine power: 110 % of the required power at stp, capacity of engine (cc): 428 or higher, air cooled, mechanical governor, class of governor a2 or better, speed 1500 rpm, 50 hz, fuel: hsd, fuel tank capacity : 15 ltr, direct injection fuel system, electric start, battery 35 ah or higher, starting voltage 12v, brushless alternator, alternator voltage 230v, manual control panel. compliance to cpcb ii guidelines of emission & noise required. type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb required. [ warranty period: 30 months after the date of delivery ] ]
Tender For auction sale of disposal of scrapped ground based hoarding and roof top hoarding,disposal of tx iron items,disposal of mdf materials,disposal of scrapped mdf tag blocks/mdf frames,disposal of scrapped mdf tag blocks/mdf frames/ runways etc,disposal of scrapped telecom miscellaneous items,disposal of scrapped 600ah bty set,disposal of scrapped 2 x 1000ah energysys make battery,disposal of scrapped 600ah battery sets- 4 nos,disposal of scrapped 6x100a powerplant,disposal of scrapped power plants without copper cables,scrapped 63kva engine alternators,disposal of scrapped engine alternators,disposal of scrapped avrs,disposal of scrapped 63kva engine alternator,disposal of scrapped mdf s copper cables and recovered pijf cables,disposal of scrapped pijf copper cables,disposal of scrapped ribbon splicing machine
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp