Tender For auction sale of depot miscellaneous scrap - blower motor plain jali with fan 12 nos,round jali blower motor with fan 06 nos centrifugal mono block pump plant no. 2923.the motor ,starters and alternators having old electrical motors of various m and p who have completed their codal life and not useful for other plants as cores and housing are damaged.1. below 1 hp 12 nos,2. 05hp 12 nos 3. 7.5 hp 09 nos 4. 10 hp 03 nos 5. 15 hp 01 no 6. 20 hp 01 no. de watering pump make kirloskar 1 sr. no. a3c22301391 5 hp coper % approx 7 % 2 sr. no. pm112m 5.6 hp copper % approx 7 %.qty. 02 nos. scrap motor pully. ferrous and non ferrous attachment if any
Tender For corrigendum : repair maintenance of electrical and mechanical services at vikas bhawan-ii, delhi (sh- repairing of existing kitchen equipments ei pump and supply, installation, testing and commissioning of cctv for health and family welfare and other miscellaneous work under sub division m-3511).
Tender For corrigendum : maintenance of electrical installation and fans, repair maintenance of a/c equipment, pump set at residential accommodations at tilak marg, daryaganj, chanakya puri and nearby areas under m4512. new delhi (sh- providing and fixing of electrical installations and audio-video system).
Tender For corrigendum : carrying out certain electrical works, networking , providing air conditioners units, motor pump sets in the quarter no 29 at road no 12 banjarahills, hyderabad part b: providing air conditioners
Tender For carrying out certain electrical works, networking , providing air conditioners units, motor pump sets in the quarter no 29 at road no 12 banjarahills, hyderabad. sub work: part a - providing electrical installation
Tender For supply of supply of module plate with frame from legrand , supply of 2 module plate with frame legrand , supply of 3 module plate frame from legrand , supply of 6 module plate with frame from legrand , supply of 3 phase vtpn 8 way distribution board , supply of 16a, 1 way modular switch , supply of single phase neutral spn 8 way distribution board , supply of single phase neutral spn 12 way distribution board , supply of 6 a way modular switch 1 module from legrand , supply of 1 module blankingplate from legrand myrius range , supply of 6 16 a modular socket outlet 2 module from legrand , supply of 6 a, 5 pin universal socket outlet 2 module from legrand , supply of 3 module surface mounting box from legrand , supply of cx modular contractor with front face handle suitable for remote switching and control of electrical loads , supply of digital weekly programmable time switch, suitable for automatic control of lighting , supply of electronic fan regulator from legrand , supply of 6 module surface mounting box from legrand , supply of 03 core x 2.5 sq.mm , supply of 3 core x 1.5 sq.mm flexible copper cable , supply of 16 sq.mm single core frls , supply of 16 sq.mm single core frls pvc insulated multi stranded copper cable , supply of 16 sq.mm single core frls pvc insulated multistranded copper cable suitable for power distribution and internal electrical wiring , supply of 16 sq.mm single core frls pvc insulated mulit stranded copper cable suitable conductor material shall be electrolytic grade annealed copper , supply of 16 sq. mm single core frls pvc insulated multi stranded copper cable , supply of 2.5 sq. mm single core frls pvc insulated multi stranded copper cable suitable for internal electrical wiring , supply of 2.5 sq. mm single core frls pvc insulated multi stranded copper cable , supply of self amalgamating rubber electrical tape designed for electrical insulation tape , supply of self amalgamating rubber electrical tape designed for electrical insulation , supply of 50 nos. heavy duty padlock, all locks to be keyed alike , supply of cotter pin , supply of pendent holder , supply of 10 u ac capacitors suitable for motor run, fan pump , supply of 15 uf 5 10 degree ac capacitors suitable for motor run , fan, pump, or general electrical equipment a , supply 02 pin male female power socket set non earth , supply of 16 amp, 3 pin plug top male , supply of 6 amp 3 pin plug top male , supply of automatic wall mounted electric hand dryers suitable for public washrooms in offices , supply of pvc square ceiling boxes suitable for installation of celing roses , supply of glands suitable for 19 mm pvc flexible conduits , supply of glands suitable for 25 mm pvc flexible conduits for securing and terninating the conduit at junction boxes , supply of glands suitable for terminating steel wire reinforced
Tender For corrigendum : repair and maint of chlorination of water and repair to chlorination injecting pumps sets, ci/di/gi distribution line, repair to ro plants, sluice valve, valve pit of pumping set and supply main etc including sewage pump sets, electrical panels, motors, sewage sumps and sewage line at n area and hallomajra under ge chandigarh.
Tender For corrigendum : bza division: bza-vskp section :setting up of quick watering arrangement at gala station. sw i:proposed 5.00lakh capacity over head tank & 3 lines of coach watering pipe lines in gala station in aden/ee sub division under the jurisdiction of den/central/bza sw ii: construction of staff rest rooms of size 5.0 x 6.0mts - 4 nos ( railway staff , contact staff and tool room and electrical staff and two stair building with size of 11x 9.00mts ( ground floor for booster pump & first floor for monitoring room), central drain at gala station in sse /works/ee section in aden/ee sub-division
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For corrigendum : tggenco-ytps (5x800 mw)-bop-ii-preventive electrical maintenance works related to ac nldb, ac wrdb, lighting, welding power supplies and its connected equipments in the common area of bop/water system/ stage-i/ytps (5x800 mw) such as raw water pump house, clarifier, cpu, foph, rail unloading (foph), pt plant, fire water pump house, foam pump house, and raw water chlorination plant etc., in bop area from 01.04.2026 or from the actual date of commencement of work to 31.03.2027 for the f.y 2026-2027.