Tender For repair and maintenance work of material testing lab equipments of m.p. state agricultural marketing board tech. division gwalior - repair and maintenance work of material testing lab equipment s, repairing and servicing of two frame ctm machine 2000kn things to be repair: hydraulic unit and general servicing, nabl calibration of two frame ctm machine 2000kn, repairing and servicing los angeles machinethings to be repair: steel balls and general servicing, repairing and servicing of cbr test machinethings to be repair: digital indicator, lvdt, load cell and general servicing, repairing and servicing of liquid limit device motorized things to be repair: belt, gear and general servicing., repairing and servicing of sieve shaker things to be repair: digital timer and general servicing, repairing and servicing of electric oven things to be repair: door handle, hinge, digital pid controller and general servicing, repairing and servicing of vicat needle apparatus things to be repair: plunger and general servicing, repairing and servicing of aggregate impact tester things to be repair: counter & general servicing, repairing and servicing of cone penetrometerthings to be repair: dial, needle and general servicing, repairing and servicing of ring & ball apparatus things to be repair: heater and general servicing, repairing and servicing of tar viscometerthings to be repair: heater, beaker and general servicing, rapid moisture meter things to be repair: pressure gauge and general servicing, electronic balance 20kg/20g, electronic balance 3kg/0.1g, flakiness & elongation gauge
Tender For conducting bridge load testing of surjopur bridge 21.0m span all including arrangement ours scope as per as department design, and data analysis and report submission under south 24 parganas division pwd during the year 20252026
Tender For conducting bridge load testing of surjopur bridge 21.0m span all including arrangement ours scope as per as department design, and data analysis & report submission under south 24parganas division, pwd during the year 2025-2026.
Tender For construction of sub centre bhogoga district kathua (electrical part). - wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, with modular switch, modular plate, suitable gi box earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required (group-a), wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire, 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 16 sq. mm + 1 x 6 sq. mm earth wire, 4 x 6 sq. mm + 2 x 6 sq. mm earth wire, 4 x 10 sq. mm + 2 x 6 sq. mm earth wire, 4 x 16 sq. mm + 2 x 6 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor single core cable in the existing surface/recessed steel/pvc conduit as required., 1 x 1.5 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 3 pin 5/6 a socket outlet, 15/16 a switch, 6 pin 15/16 a socket outlet, supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required, supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 a modular socket outlet and 2 nos. 5/6 a modular switch, connections etc. as required. (for light plugs to be used in non residential buildings)., supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, "c"curve including connections, painting etc. as required., supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required., 1 or 2 module (75mm x 75mm), 3 module (100mm x 75mm), 4 module (125mm x 75mm), 6 module (200mm x 75mm), 8 module (125mm x125mm), 12 module ( 200mm x 150mm), supplying & fixing of following way single pole and netural, sheet steel, mcb distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required., 6 way (double door), 16 way (double door), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/ rccb /isolator), 6 way ( 4+18), (double door), 8 way (4+24), (double door), supplying and fixing following rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole 6/10/16/32 amp, single pole and neutral 32 amp, single pole and neutral 63 amp,
Tender For echp-ii- complete overhauling and load testing the various capacity chain blocks at various location of primary crusher house-ii secondary crusher house-ii
Tender For ttps es circle em iii load testing of 2 nos 15 tonne capacity wire rope electric hoists at id fan 4a and 4b and 5a and 5b of unit iv and v boiler area
Tender For preventive / maint and painting of hot/eot cranes including load testing and repair / rewinding of motors at nad explosive area, nad technical area, tunir area at naval station karanja
Tender For providing erecting and fixing of electric pole accessories from check post main road to say site bucharwada panchayat area diu - supplying and erecting led street light fittings with high power white leds wattage of 3 watt and above assembled on single mcpcb, efficiency more than 130 lm/w and corrosion free high pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics/ lenses, with toughened glass with company mark/ name engraved or embossed 160 to 270v, power factor more than 0.95, thd 10%, cct 3000k to 5700k,uniformity ratio >0.45, luminaire efficacy> 100 lumens/ watt. led driver efficiency > 85%. (fittings required lm-79 & lm-80 certificates) (note: below description have shown ranges of wattage capacity of led fittings. the engineer in charge may select any wattage capacity between the ranges shown.) (a) street light (ip-65), surge protection- 4kv integral and, light must have 440vac line supply with over-voltage protection. 90 watts cat. ii (make: wipro, crompton, philips, bajaj, osram) as directed by the engineer-in-charge., providing and erecting street light pole bracket comprising main b class gi pipe of 4.2 cm/ require outside dia. complete with suitable b class g.i sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of red oxide / pu base primer and two coats of aluminium / pu paint. paint with following nos of arms. single arm bracket 1 mtr, providing and erecting xlpe (is:7098) (i)-88 isi armoured cable multistrand aluminium conductor for 1.1 kv. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (a) 4 core 16 sq. mm, supplying and erecting flexible pvc insulated multi strand multi core 1.1 kv grade isi marked copper wires of following size to be erected as directed 1.50 sq.mm 3 core round pvc sheathed., providing and erecting pipe type earthing having 150 cms. long and 2.5 cms. dia. galvanised iron pipe with coupling and buch buried in specially prepared earth pit complete with necessary 8 swg earth wire., supplying & erecting earth pit of minimum bore dia. 150mm size approved make earthing electrode consisting pipe-in-pipe technology as per is 3043-1987 made of corrosion free hot dipped g.i. pipes having outer pipe dia of 50mm having 80-200 micron galvanising, inner pipe dia of 25 mm having 200-250 micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (approved make oem has to submit test certificate) & having back filling compound of (b) inner chemical (ccm compound)- resistivity:- 0.2 / meter testing as per iec 62561-2017, voltage drop:- 1 volt at no load & dry form, sulphar content:- 2%(c) back fill compound :- earthing compound should be capable to retain moisture for long time necessary test report must be submitted. (b) for electrical installation up to 11kv in normal soil length of pipe - 2.00 mtrs back filling compound - 1 nos bag of 25 kg., making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground., making trench in hard murrum / tar road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground., providing & laying approved make isi marked hdpe 6kg / cm2 (class-3) as per is:4984:1995 pe-80 to be erected at road crossing on or floor as directed for laying of cable. the pipes as follow
Tender For corrigendum : design, engineering, manufacture, assembly, testing before dispatch, supply and delivery in well packed condition of 11 kv,800a, sc level 40ka for 1 sec load break switch panel ,scope also includes dismantling and removal of existing (old) 02nos.lbs panels of ngef make, disconnection of power cables and control cables and erection of new panels, power cable & control cable connection, bus bar connection, panel connection, testing, and commissioning, lbs shall conforms to iec62271- 102:2003 . detailed scope and gad,bom is as per attached annexures-i to iii