Tender For repair and maint of overhead water tank, air compressor, irp, chemical dosing system, borewell, starter panel incl external pipeline network and connected items installed at various pump houses at af stn mohanbari
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For repair of electrical pumping sets complete with starter, switches, gen sets, transformer and supplying of sodium hypochlorite and adding it to water in mc nangal for one year
Tender For supply of spares of main da for icgs saksham - supply of following spare, air starter repair kitp.no.-kit 3026797 a, seal grommet p.no.-3035331, gasket turbo charger p.no.-3011876, seal o ring p.no.-145506, shaft, pivotp.no.-3003393", gearp.no.-3392992, pressure transmitter (0-6bar) p.no.-5543058/4927803, screw, socket head capp.no.- 216869, bushingp.no.- 3060905, bearing rollerp.no.- 3003354, shaft, idlerp.no.- 300320, gasket flangep.no.- 3014449, nipple, pain pipep.no.-s946, fitting, greasep.no.-s2268, dowel pinp.no.- 69558, screw, twelve point cap p.no.-3028279", retainer, screen p.no.-174299, plug, threadedp.no.-173085, plug, ballp.no.-3047963
Tender For repairing and rewinding, lowering-unlowering, starter repair of submersible motor pumpset on complete o&m basis under jen section -1st city sub division karauli.
Tender For repairing and rewinding, lowering-unlowering, starter repair of submersible motor pumpset on complete o&m basis under jen section -2nd city sub division karauli.
Tender For corrigendum : motor rewinding works of submersible pump set along with unlowering lowering and starter repair at various rwss in jen section renwal manji and madhorajpura under sub dn. chaksu
Tender For annual repair and maintenance of various lwss wss and tube well under sub-division jawali in tehsil jawali distt. kangra hp sh dismentling and relaying of gi pipe line at tube well bhaglahar banara jhonka ratial and kardial 59 dismentling and - name of work :- a/r & m/o of various lwss/wss/ tube well under sub-division jawali in tehsil jawali distt. kangra (hp) (sh :- dismentling and relaying of gi pipe line at tube well bhaglahar, banara, jhonka ratial and kardial-59, dismentling & relaying of rcc pipe 250mm dia at t/well kardial-v and papahan, c/o rcc outlets in t/well banara, providing and fixing new starter 45hp at t/well butt, repair of boundary wall at t/well kharota and samkehar and repair of pump house in t/well kardial-3rd and lwss thather mohalla)