Get complete information related to latest Engine Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Engine Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Engine Switch Tenders.
Tender For w acting for and on behalf of the president of india invites e-tenders against tender no e-73-dyceekgpw-cbc-26-27 closing date/time 01/07/2026 15:00 hrs. bidders will be able to submit their original/revisedbids upto closing date and time only. manual o ers are not allowed against this tender, and any such manual o erreceived shall be ignored.1. nit headername of workupgradation of cbc overhauling section and corrosion repair shop of wagonrepair shop, kharagpur workshop.bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime01/07/2026 15:00date time of uploadingtender09/06/2026 16:38pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 2402108.76tendering section elegenbidding style single rate for tender bidding unitabove/below/parearnest money (rs.) 48100.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 18 monthscontract type works - general contract category expenditurebidding start date 17/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-cost of supply of material for electrical work1712792.421a12.00numbers383500.00 767000.00 at par 767000.00description:- supply of incoming 1x 630a,4p, 50ka mdo type microprocessor based acb withipr1+ release & outgoing (i)2 x 320a,4p, 36ka thermal magnetic release with adjustable thermal &fixed magnetic mccb (ics=100%icu),(ii)2 x 200a,4p, 36ka thermal magnetic release withadjustable thermal & fixed magnetic mccb (ics=100%icu),(iii)4 x 100a,4p, 36ka thermal magneticrelease with adjustable thermal & fixed magnetic mccb (ics=100%icu) tted in lt panel box14swg crca sheet powder coated 4way cu busbar of suitable rating, indicator lamp, digitalmultifunction meter & all other accessories. mccb & acb make:- havellls/ lk/ schneider/siemens.2a210.00numbers 400.02 4000.20 at par 4000.20description:- supply of mcb metal enclosure 4 pole3a380.00numbers 413.00 33040.00 at par 33040.00description:- supply of pyramid insulator as per drawing4a470.00numbers 531.00 37170.00 at par 37170.00description:- supply of pin type insulators as per drawing.5a550.00numbers1121.00 56050.00 at par 56050.00description:- supply of gi-angle (40 x 40 x 06 mm) bracket 4 way with porcelain insulator as perdrawing suitable for overhead light.6a610.00numbers 248.98 2489.80 at par 2489.80description:- supply of mcb metal box 2 pole7a720.00numbers1323.96 26479.20 at par 26479.20description:- supply of 16/20/25a power unit (containing 4 module plate, starter, socket and plug)for ac unit.8a85.00numbers11434.20 57171.00 at par 57171.00description:- supply and testing of oscillating type bldc pedastal fan, 230 v,400 mm sweep,multi speed, remote/button controlled make- atomberg, havells, crompton, bajaj, usha, orient.9a9 150.00 metre1150.50 172575.00 at par 172575.00page 1 of 18run date/time: 09/06/2026 16:38:46kgp-workshop-electrical/south eastern rlytender documenttender no: e-73-dyceekgpw-cbc-26-27closing date/time: 01/07/2026 15:009description:- supply of hot dip galvanized 2mm thickness perforated cable tray of size 300 mmwidth and 50 mm height and complete accessories as per is, ie rules and site requirement10a10 50.00 metre 575.25 28762.50 at par 28762.50description:- supply of cable trays 2mm thickness size 100 x 50 mm gi, perforated (rmt) withcover complete and as per is, ie rules and site requirement.11a11 10.00numbers 180.54 1805.40 at par 1805.40description:- supply of combined switch socket box - 16 a, capton 5-in-1 combined switch andsocket with isi mark,as per is:3854 or latest12a122.00numbers34700.26 69400.52 at par 69400.52description:- supply of 4 pole mccb ,release range (80-200)a, breaking capacity 36 ka,microprocessor release with inbuilt earth pr
Tender For supply of 3 pole 440v 50hz mnx400 power contactor as per atc , 3 pole 440v 50hz mnx225 power contactor as per atc , 3 pole 440v50hz mnx185 power contactor as per atc , 3 pole 440v 50hz mnx110 power contactor as per atc , 3 pole 440v 50hz mnx70 power contactor as per atc , 3 pole 440v 50hz mnx32 power contactor as per atc , auxiliary switch with 6no and 6nc suitable for c power breakers as per atc , c power breakers rack in and out handle 3200a 4000a as per atc , trip lock key of c power acb breaker as per atc , single phase micro-controller as per atc
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply of lauritz knudsen (formerly l & t) make switchgear spares for chp elect- fuel section at gsecl ukai tps. (chp maintenance (electrical)-et-6304) - l&t make 3 pole power contactor, type- ml-2, ac-3, 32 a, 415 v ac, l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make,3pole power contactor ml-6,coil voltage 110vac, ac-3 rating 110a cat.no. ss90921, l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, l&t make 3 phase power contactor type mnx 25 ac-3 rating 25a,cat.no.cs94110, l&t make 3 phase power contactor type mnx32 ac-3 rating 32a,coil voltage 110v ac,cat.no.cs94111aooo, power contactor mnx 40 coil:110vac cat no.:-cs94190 make:-l&t, l&t make 3 phase power contactor type mnx110 ac-3 rating 110a,coil voltage 240v ac,cat.no.cs94137, l&t make power cantactor type- mnx 300 with 2 no + 2 nc aux. contact, coil voltage 110 volt ac, ac-3 rating 300 amp., cat. no. cs 90280., l&t make,3pole power contactor in open execution type mn-400 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 400 * cat.no.ss 94043, l&t make 415v switch gear (acb), contactor kit ml-2 ss 95307, l&t make contact kits with out coil for contactor type:- ml 4, cat.no - ss 91257, spares kit without coil for contactor ml6, cat. no. ss 95313, make - l & t, l&t make spare kit without coil for ml-10 cat no ss 95315, l&t make 415v switch gear (acb), l&t make spare kit without coil for ml-12,cat no.ss 91127,l&t make 415v switch gear (acb), spare contact kit for l&t make mnx 110 power contactor cat no cs94154, spare contact kit for l&t make mnx 400 power contactor cat no cs94161, coil for l&t make power contactor. ml-8/10/12 ss91011, 220vac,/110vac, l&t make spare coil for mnx 400, coil voltage 110 vac, cat no cs94195, l&t make fornt mounting add-on block 2no + 2nc cat. no.cs94114 for mnx 9a to 40a contactor, l&t make, mnx type front mounting add on aux. contact block 1 no + 1 nc, cat no cs94118, l&t make, mnx type front mounting add on aux. contact block 3 no + 1 nc, cat no cs94113, l&t make control , contractor type mm01 with 4 ho +4hc contact , coil voiltage 110 vac cat no. ss 92014, l&t make 415v switch gear (acb), l&t make control contactor, type mm01 ac with 5 no +3nc contact , coil voiltage 110 vac, cat no. ss 92014, l&t make 415v switch gear (acb), l&t make dc control mx mini mx 09 1nc cat no cs94024, l&t make bi metal o/l relay for ml -2 range 9.0-14a , cat no ss 9185900ao, l&t make 415v switch gear (acb), l&t bimetal thermal overload relay with single phasing protection.mn-2 9.0-15.0a ss94142, l&t make ml type,thermal overload relay, range 20-32amp,direct mounting on ml 2/3 contactors,cat no-ss91859ooeo, bimetallic relay with single phasing protection, range: 66-110a, make: l&t, cat. no.-cs9422700k0, l&t make bimetal thermal over load relay with single phasing protection, mn 12 type, cat.no. - ss94138oomo, relay range 3 - 5 amp operation, ct operated in combution with 90 - 150 amp (ct operated) seprate mounting., l&t make b/m o/l relay,mn-12 l type,range-180-300a,cat no-ss 94127 ooqo, l&t make bimetal (th) over load relays ( with single phasing protection) thermal o / l relaytypemn 2cat.no.ss 9412700 porelay range3 - 5 ampoperationct operatedin combution with 90 - 150 amp ct mounted on ct, switch disconnector fuse unit tpn 32a 415v make:-l&t type:-fn, l&t make switch disconnector (415 volt, 50 hz) fuse units type: fn 63 tpn, cat.no.: sk 95421, capacity:- 63 amp, ac, 23 amp, no of poles: 3 + n link, l&t make switch disconnector-fuse, type-fn 125, 125amp, tpn+fuse links, cat no- sk 95001., l and t make switch disconnector isolator, type fn 250 tpn, cat. no. sk95683., landt make switch disconnector-fuse, type-fn400, 400amp, tpn, cat no
Tender For corrigendum : (1)complete repairing overhauling of 400 amp 11kv vcb meditron make sl no mdo0353 of coal dump colony ,(2) complete repairing/overhauling of 800amp, 440v, acb switch sl no.-1396 prabhu make
Tender For auction sale of depot miscellaneous scrap - old used and u/s electric and electronic items and siginaling items, led street light fittings, modem, change over switch, megneto telephone, fuse auto change over time element , leds for different signals, refrigerator, highmast fittings, helogen fittings, contactors, lt acb switch, starter, sterlizer, current regulator, dtmf lc gate telephone, grinder, tree cutter, stm-1 optical fiber cable equipment, vhf set, emergency port. control tele., auto telephone, lc gate master telephone, smps charger, digital clamp on meter, mh fittings, led street light, flood light, 3d light fittings, lv box for axle counter, counter mnx various size, gyser, exaust fan, wall fan, electronic instrument, electric tracking m/c, set top box, electric torch, vaccum cleaner, timer switches, register for ups, igbt for ups, ic for ups, diode, capacitor, energy meter, dc-dcconverter, klcr, water purifyer, ufsbi, axle counter, ac timer, eld, tag block, continuous rail thermometer, air blower, hand dryer, ms relay base, ht socket, pet quad repeater, drill m/c, metal detector,, thermal cut, bomb suit, junction detector visual kit, vapour explosive detector, water desrupter, speaker, amplifier, mixer etc items (requrired pollution certificate)(5% nf approx and 95% plastic and ms and other material approx) (indicative approximations are only for reference, not to claim)(location godown 7)
Tender For auction sale of pway scrap - c.i. scrap consisting cst-9,do plate, cst-9 broken,cms block, switch block, check block, sej chair,acb plate,stopper and p.way fitting etc. (in 3 stack). other details attached as per tms/udm lot no. 014760-26-00021.
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k