Web Analytics Made Easy - StatCounter

Environmental Footprint System Tenders

Get complete information related to latest Environmental Footprint System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Environmental Footprint System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Environmental Footprint System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45509999 Due date: 24 Jun, 202624 Jun, 2026 12.40 Lacs
Tender For work of servicing, maintenance, calibration of pneumatic and motorized valves, coal mill dp measurement system, auxiliary air dampers power cylinders and other miscellaneous works in forthcoming overhaul of unit #3.

corporations/Associations/Others

CTN :45520206 Due date: 06 Jul, 202606 Jul, 2026 9.17 Lacs
Tender For procurement of different eot cranes accessories, electrical changeover switch for emd-iii and spare parts of hoist and crane for emd-ii etps htps kasimpur - down shop lead (dsl) 125 a 4 pole with all accessories for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), master controller for lt 4 steps for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), master controller for mh 4 steps for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), master controller for ct 4 steps for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), ac brake for lt 160 mm for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), ac brake for mh 250 mm for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), ac brake for ct 100 mm for 15 ton eot crane , make khandelwal udyog ltd., location -cw pump house ctps (1*110 mw), ac brake for ah 200 mm for 30/5 ton eot crane , make khandelwal udyog ltd., location -tg hall ctps (1*110 mw), electro hydraulic thruster brake dia 250 mm ,34 kg with brake pad & brake liner for ah for 30/5 ton eot crane , make khandelwal udyog ltd., location -tg hall ctps (1*110 mw), electro hydraulic thruster brake for mh dia 300 mm ,34 kg with brake pad & brake liner for 30/5 ton eot crane , make khandelwal udyog ltd., location -tg hall ctps (1*110 mw), ac brake for lt 250 mm for 30/5 ton eot crane , make khandelwal udyog ltd., location -tg hall ctps (1*110 mw), ac brake for ct 160 mm for 30/5 ton eot crane , make khandelwal udyog ltd., location -tg hall ctps (1*110 mw), electro hydraulic thruster brake for lt 200 mm ,34 kg with brake pad & brake liner for 120/30 ton eot crane , make- russian., location -tg hall ctps (1*110 mw), onload changeover switch 4 pole 200 amp 415 volt#type of product:onload changeover switch#,standard-is: 13947 iec 60947-3,unit of measurement piece#frequency-50 hz,rated current (a):200 a,selling unit each#rated voltage-415 v,no. of pole:4 pole,#enclosure sheet, make- havells, schneider ,l&t,abb,hpl, 4 pole change over switch 320 amp#type of product:onload changeover switch#,standard-is: 13947 iec 60947-3,unit of measurement piece#frequency-50 hz,rated current (a):320a,selling unit each#rated voltage-415 v,no. of pole:4 pole,enclosure:steel sheet, make- havells, schneider ,l&t,abb,hpl, onload changeover switch 4 pole 400 amp 415 volt#type of product:onload changeover switch#,standard-is: 13947 iec 60947-3,unit of measurement piece#frequency-50 hz,rated current (a):400 a,selling unit each#rated voltage-415 v,no. of pole:4 pole,enclosure: sheet, make- havells, schneider ,l&t,abb,hpl, voltage-110v ac, 1 no, 3-phase, 415v ac, power contactor a30-30-10-84, current rating - 30a, coil voltage-110v ac, 1no, 3 phase, 415v ac, addon block auxilary contact mnx a2, auxiliary relay, model-my4n-100,50hz,110v ac, contactor ax32-30-10-80,220-230v,50hz, contactor ax09-30-10-80,220-230v,50hz, contactor mnx18 18a,220v,1nc,3pole., contactor 3tf 30-10-10e,220-230v,50hz., contactor ax32-30-10-84,220-230v,50hz., 3 pole power contactor mnx32 in 110v ac, aux contact block 2a ca5 x-10 1no contact, aux contact block 2a ca5-01 1nc contact, olr 3ru2116-1kbo,09a-12.5a., olr ta25du-1.8m,1.3a-1.8a., olr ta25du-15m,10a-14a., olr ux1418,1.25a-2.0a., control transformer 415vac/110vac,200va, control transformer 415vac/110vac,250va, 1-phase 415/110v,50hz,1000a,150va control transformer (panel) insulation class-f , primary current-0.361a, secondary current-1.364a,il-0.66/3kv, miniature relay g2r-2-dc5-5v 5a two set of conversion 2c(dpdt conversion)dip,12.7x28.8mm power relay rohs

State Government

CTN :45525068 Due date: 29 Jun, 202629 Jun, 2026 41.51 Lacs
Tender For routine monitoring / preventive maintenance / breakdown / emergency /regular servicing of pneumatic cylinders, solenoid valves, limit switches & pressures switches pertainsto units-5,6 &7 mill reject handling system(mrhs).operation and maintenance of dense phase mill reject handling systemof unit-8.the work involves-a)operation and maintenance of dpmrhs plc systemb)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves,limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systemspertains to unit-5 to 8.the work involves-a)operation and maintenance of dpmrhs plc system.b)i&c maintenance works of air compressor.c)servicing/re-calibration of solenoid valves, limit/proximity switches & pressures switches etc.routine monitoring/maintenance of spm analyzer systems pertains to unit-5 to 8.the work involves-a)cleaning/servicing of transmitters & reflector units and blower filters of spm analyzers, pertains to units-5 to 8.b)carrying out maintenance works under the supervision of i&c engineerregular monitoring/checking healthiness of unit-7&8 coal bunker level monitoring systems.routine maintenance of bunker level monitoring systems.the work involves- a) cleaning/checking of 3d level sensors.b) cleaning/checking healthiness of local control panel at bunker floor.c) ensuring healthiness of signals to control room pc,dcs&chp control room digital indicators.regular monitoring/maintenance of hfo tanks level measurement systems.the work involves-a)cleaning/checking healthiness of radar level transmitters installed at hfo tanksb)cleaning/checking healthiness of local digital indicators installed at foph.c)cleaning/checking healthiness of plc unit installed at unit control room-7.the nature of work is round the clock maintenance.the cleaning/servicing and maintenance works of all the above mentioned systems shall be carried out during units aoh period.the required t&p and ppe for carrying out maintenance works shall be arranged by the contractor/agency itself.

CTN :45384472 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For corrigendum : purchase of equipments for dmt department lab - purchase of equipments for dmt department lab, fanuc cnc simulation trainer kit system type: standalone cnc simulation trainer with integrated hardware panel functionality: switchable milling (3-axis) and turning (2-axis) simulation cnc control: original fanuc control system or officially licensed equivalent software: manual guide i (licensed version) for conversational programming and 3d simulation programming: supports g code (iso standard) and conversational programming storage: minimum 512 kb program storage with at least 400 programs tool offsets: minimum 32 pairs coordinate system: g52 g59 with minimum 48 additional work offsets (milling) display: minimum 10 color lcd input: full qwerty keyboard connectivity: usb, ethernet interfaces: rs232 / i/o link power supply: 100 240 v ac, 50 60 hz power consumption: 100 w construction: industrial grade trainer unit , robotic arm controllerdegrees of freedom: 6 dof payload: minimum 250 g at full reach reach: minimum 350 mm repeatability: 0.2 mm or better controller: industrial-grade controller (arm cortex-m4 or higher / equivalent architecture) programming: supports gui based and programming (python / c++ / equivalent) vision system: integrated camera with ai-based object detection capability communication: usb and serial communication software: licensed software compatible with windows os end effectors: minimum 3 (gripper, suction cup, pen holder) safety: emergency stop, limit protection power supply: 100 240 v ac, 50 60 hz, optical digital microscopemagnification: 40x to 400x digital camera: minimum 5 mp resolution display: pc/monitor via usb/hdmi or built-in display illumination: adjustable led illumination focus: coarse and fine focusing mechanism optics: coated lenses with wide field view stage: mechanical stage with slide holder software: image capture, measurement, and analysis software included connectivity: usb / hdmi /ethernet power supply: 110 240 v ac, 50 hz, portable surface roughness tester parameters: ra, rz, rq, rt measuring range: ra: 0.005 16 m rz: 0.02 200 m resolution: 0.01 m accuracy: 5% or better stylus: diamond tip ( 5 m radius) cut-off lengths: 0.25 mm, 0.8 mm, 2.5 mm display: digital lcd output: usb interface for pc connection standards: iso 4287 / din / ansi compliant power: rechargeable battery

CTN :45516001 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto

CTN :45535164 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply and installation of additional accessories, as per the list for existing benchtop fluorimeter. a) quantum yield measurement unit b) polarization accessories c) low temperature accessories

State Government

CTN :45160817 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For corrigendum : ndt testing such as radiography, fibroscopy, thickness measurement, dpt and mpi testing of boiler tubes unit-i at 2x300 mw, dcrtpp, hpgcl, yamuna nagar

Central Government/Public Sector

CTN :45477664 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For corrigendum : procurement of bunker level measurement c and i spares for vstps stg5 - strain sensor,014308,thermo fisher, instaltn kit,014803,thermo, level cntrlr unit,046634,thermo

Central Government/Public Sector

CTN :45493368 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of inertial measurement unit 152.4x127x104mm

CTN :45324767 Due date: 19 Jun, 202619 Jun, 2026 38.91 Lacs
Tender For corrigendum : procurement of various testing equipments used for transformers, protection relays, and circuit breakers of unit 1 and 2 katpp, jhalawar - various testing equipments for transformers, protection relays, and circuit breakers, transformer winding resistance meter(25a dc max. current injection, multiple autoand manually selectable measurement ranges: 200 to 2k ), earth ground resistance testing kit(measuring range 2 m to 10 k ), contact resistance measurement kit(test injection current max. 200a dc, resistance range 200 to 20 m ), relay testing kit (single phase)(output current range :- 0 to 30 a at 200 va continuously up to 60 a at 300 va for short duration, output voltage range :- 0 to 300 v at 150 va)
 Loading, Please wait...

Connect us via What's Up