Get complete information related to latest Eurorack System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Eurorack System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Eurorack System Tenders.
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin mechanic motor vehicle (mmv) tradeat iti tarsali, gujarat, india (package 3: mmv trade) - alternator assembly used for lmv working condition demonstration kit , starter motor assembly used for lmv working condition demonstration kit , electronic engine control module , fuel pump for mpfi working condition demonstration kit , inline fuel injection pump and rotor type fuel injection pump , demonstration board of 2wheeler ignition system. , demonstration board of electronic ignition system. , working condition of petrol mpfi engine assembly with fault simulation board , mpfi petrol engine with swiveling stand along with special tools for dismantling and assembling , demonstration board of mpfi system , ultrasonic injection cleaning equipment , working model of power windows , petrol engine motorcycle/scooter along with special tools and accessories , four stroke multi cylinder diesel engine in working condition , four stroke four cylinder crdi diesel engine in working condition , functional/experiment model of different type of sensors. , auto electrical test bench , cut section model of mock layout of a motor car -electrical system - working model , cut section working model of single plate clutch assembly. , cut section working model of diaphragm clutch assembly. , cut section working model of centrifugal clutch assembly. , front axle ( rezeppa joint) with stand for dismantling and assembly , rear axle with stand for dismantling and assembly , cut section model of synchronous gear box working , cut section model of sliding mesh gearbox working , cut section model of constant mesh gearbox working , full floating axle and semi- floating axle assembly , cut section working model of automatic transmission gear box , steering assembly - , 1. rack& pinion, , 2. worm& roller , 3. recirculating ball , 4. power steering , wheel alignment set up instrument-computerized , brake testing equipment (to test efficiency of vehicle where motion after braking is plotted) , motor vehicle in running condition (diesel heavy) with hydraulic power steering , light motor vehicle diesel crdi with electronic power steering and car a/c , engine dynamometer , four stroke multi cylinder engine mpfi petrol with cng kit set up in running condition , four cylinder four stroke diesel engine test rig with rope brake dynamometer , exhaust gas analyzer - diesel , training setup for adas systems , 4-wheel alignment set & hoist with advanced driver assistance systems (adas) complete frame targets , steel toolbox with lock and key (folding type) , punch letter , outside micrometer (0 25) , outside micrometer (25 50) , outside micrometer (50-75) , outside micrometer (75-100) , inside micrometer (25-50) , depth micrometer (0-25) , thread micrometer , adjustable micrometer sprit level to measure flatness, indication and taper with prismatic measuring base , vernier caliper , digital vernier caliper , vernier depth gauge , vernier bevel protractor, least count 5minutes , telescope gauge , dial test indicator plunger type (complete with clamping devices and stand) , universal surface gauge , cylinder bore gauge , compression testing gauge suitable for petrol engine. , vacuum gauge , granite surface plate , work bench , spanners socket with speed handle, t-bar, ratchet and universal , magneto spanner set , cylinder ridge cutter , vice grip pliers , torque wrenches , pneumatic tools set , car jet washer , pipe flaring tool , pipe cutting tool , universal puller for removing pulleys, bearings , stud extractor set of 3 , stud remover with socket handle , paraffin pressure gun , hand reamers adjustable , straight edge gauge , straight edge gauge , ladle , electric soldering iron , wire gauge (metric) , digital multi meter, 3 % digit (min), diode test mode and continuity mode, , growler , hydrometer , battery analyzer with printer , carburetor - solex, mikuni for dismantling a
Tender For supply of electrical protective devices - electrical protective devices ( l & t / legrand / indoasian), mcb single pole, a) 1 a, b) 2 a, c) 3 a, d) 6 a, e) 10 a, f) 16 a, g) 20 a, h) 25 a, i) 32 a, j) 40 a, k) 63 a, mcb double pole, a) 1 a, b) 2 a, c) 3 a, d) 6 a, e) 10 a, f) 16 a, g) 20 a, h) 25 a, i) 32 a, j) 40 a, k) 63 a, mcb tpn , a) 10 amp, b) 16 amp, c) 20 amp, d) 25 amp, e) 32 amp, f) 40 amp, g) 63 amp, mcb triple pole three phase, a) 10 amp, b) 16 amp, c) 20 amp, d) 25 amp, e) 32 amp, f) 40 amp, g) 63 amp, mcb single pole iron box (mds/l&t/indo asian/havel s/siemens/legrand), mcb d.p. iron box (mds/l&t/indo asian/havel s/ siemens/legrand)), mcb tp iron box, mcb four pole iron box, mcb 6 way box (mds/l&t/indo asian), mcb 8 way box (mds/l&t/indo asian), mcb 12 way box (mds/l&t/indo asian/ siemns), mcb tpn db 12 way box (mds/l&t/indo asian), icdp main switch 16 amp. fuse type, icdp main switch 32 amp. fuse type, ictp main switch 32 amp. fuse type, ictp main switch 63 amp. fuse type, ictp main switch 100 amp. fuse type, ictp main switch 200 amp. fuse type, kit-kat 15 amp. 250 volt, kit-kat 30 amp. 440 volt, kit-kat 63 amp. 440 volt, kit-kat 100 amp. 440 volt, kit-kat 200 amp. 440 volt, motor protection circuit breaker . as per is/iec : 60947-4-1 (l&t/indo asian/siemens/legrand), a) 0.4 to 0.63 amp, b) 0.63 to 1.6 amp, c) 1.6 to 2.5 amp, d) 2.5 to 4 amp, e) 4 to 6 amp, f) 5.5 to 8 amp, g) 7 to 10 amp, h) 10 to 13 amp, i) 13 to 18 amp, 1) star delta starter 10 h.p. (l&t/ siemens), 2) dol starter(0.5 hp to 5hp), 3) 4 pole contactors 16 amp, 4) 4 pole contactor 25 amp, 5) 4 pole contactor 40 amp, 6) 4 pole contactor 95 amp, 7) 4 pole contactor 125 amp, 8) contactors for 10 hp motors (mk), 9) on delay timer (eletx), 10) off delay timer (eletx), 11) timer (3-10 sec), a) c - channel for mounting mcb & contactor within panel, b) d rail channel for mounting mcb, mpcb & contactors, relay within panel., hrc fuse, a) 4a, b) 6 a, c) 10 a, d) 16 a, e) 20 a, f) 25 a, g) 32 a, h) 40 a, i) 63 a, j) 100 a, k) 200 a, m) 400 a, fuse wires, a) 5 a;, b) 10 a;, c) 16 a;, d) 25 a;, e) 32 a;, f) 63 a;, over load relay as per is/ iec : 60947-4-1 ( l& t, siemens, legrand, indoasian), a) 0.4 to 0.63 amp, b) 0.63 to 1.6 amp, c) 1.6 to 2.5 amp, d) 2.5 to 4 amp, e) 4 to 6 amp, f) 5.5 to 8 amp, g) 7 to 10 amp, h) 10 to 13 amp, i) 13 to 18 amp, mccb four pole ( l& t, siemens, legrand, indoasian), a) 32 amp, b) 40 amp, c) 63 amp, d) 100amp, e) 125amp, f) 200 amp, g) 250 amp, h) 400 amp, elcb ( l& t, siemens, legrand, indoasian), a) dp 16 amp, b) dp 25 amp, c) dp 40 amp, d) fp 16 amp, e) fp 25 amp, f) fp 40 amp, g) fp 63 amp, h) fp 125 amp, rccbconforms to is : 12640 & iec 61008-1,degree of protection : ip 20,sensitivity rating : 30ma / 100ma / 300ma short circuit with stand capacity of 10ka with scpdon-off indication,test button t is provided for periodic check up, a) dp 25 amp, b) dp 40 amp, c) dp 63 amp, d) fp 25 amp, e) fp 40 amp, f) fp 63 amp, switch fuse unit three phase, hrc type (l & t, indoasian, siemns), a) 125 amp, b) 200 amp, c) 400 amp, level cotroller (l & t, siemens, gic, ), a) for single tanks control, b) for two tanks control, level sensing probes (ss), level monitoring switches, floating switch with two contacts (no+ nc), magnetic level sensing probe, electronic timer chrono (radix, gic, siemens, schnider), electronic timer astrological (radix, gic, siemens, schnider), vertical tpn db with provision for mccb upto 125 aas incomer (indoasian /havells/siemens), a) 4 way, b) 6 way, c) 8 way, earthing plate, 1) copper 300x300x3, 2) copper 600x600x3, 3) g.i. plate 600x600, 4)g.i. bare conductor, 5)copper bare conductor (10swg), 6)g.i. strip, 7)copper strip
Tender For procurement of consumable items and general spares for miscellaneous equipment along with safety items (ppe) for dhalipur power house - consumable, general spare and ppe items, old dhoties dully washed 3 to 5 meter long, old cotton dhoties washed/cleaned , length not less than 3 meter, width not less than 1 meter, white cotton cloth ( jute ) dry & clean thread waste ( white ) of spinning / weaving mill in good condition., white markin for cleaning purpose, high capability property to absorb oil, water and other liquid, 100 percent cotton, white texture, excellent strength,, jute carpet roll (tat patti) having a width-01 meter, modacrylic coverall / protex coverall flame resistant, colour blue,or grey size-l to xxl(3nos.of each size),disposable fabric: flamex (55% modacrylic, 43% cotton 2% antistatic)make-3m, wire braded flexible hose pipe id-25 mm,pressure range-0 to 10 kg/cm ,colour- black.make-mithra italia flex,global,polyhose, aira make nrv 15 mm ,high pressure 0-100 kg/cm , body-ss ,ends-screwed (f) to bsp, 1/2 ball valve ,pressure range-0 to 100 kg/cm ,3 piece ball valve ,body-ss make-zoloto/aira,f/b-r/b=f/b,end type-se,f to e=64 mm, l&t make fn 63 tpn/fp ce switch with enclosure sk90484 with interior fuse unit,, l&t make hrc fuse cylindrical type 63 amp cat-sf90159, l&t make mnx 32 power contactors 240v ac (3 pole),model no-cs94111dooo, l&t make mnx contactor 95a 3p 415v ac ac-3 ,aux supply-415v ac coil, freq-50/60 hz,model no-cs94136dooo, l&t make mnx contactor 70a 3p 415v ac ac-3 ,aux supply-415v ac coil,freq-50/60 hz,model no-cs97076dooo, l&t make mnx contactor 50a 3p 415v ac ac-3, aux supply-415v ac coil,freq-50/60 hz,model no-cs97075dooo, l&t make mnx contactor 12 a 3p 415v ac ac-3, aux supply-415v ac coil,freq-50/60 hz,model no-cs94109booo, siemens make contactor relay 4no 24v dc,model-3rh214001bb40, l&t make 66-110 a thermal overload relays for mnx contractor, model no-ss94137ooko, l&t make motor protection relay mpr300,240v ac,o/l range (a): 32-88 a,aux supply-240 v ac, l&t make mnx-a1 add on block.2no+2nc 4 poles contactor, sku:cs94114oooo, gic make sm 301,single phase preventer relay,protects against phase loss, phase reversal & phase asymmetry, gic make sm 800 supply monitoring series relay,model-gicdma220,phase and voltage control,voltage-85-300 v ac/dc,relay out put -2 c/o,monitoring of under-over voltage & frequency in 3 phase systems for line/phase voltage.monitoring of phase loss, phase sequence, phase asymmetry & neutral fail. measure true rms ac voltage. self & auxiliary power devices.configurable power on delay, off delay & on delay., gic make-multifunction electronic timer relay,model-gic-2aadt5 micron 225,24 - 240 v ac/dc,mounting type-base / din rail, switzer make pressure switch model-711, pressure range-0 to 100 bar ,output ac=100v-240v ac,output -18 v to 36 v dc,sensor material-ss 316,process connection-1/2 npt (m), regulated power supply unit, incoming voltage-100 vac to 240 vac, 140 vdc to 340 vdc ,stable output-voltage (v dc): 24.output current (amp): 10,output power (watt): 240,line regulation: 0.5% (full load).load regulation: 1% (230 vac i/p).make-schneider,abb, ball valve 25 mm ,body-ss- 316,pressure range-0 to 100 psi, end connection type-threaded,make-skilt,leader,aira, 40mm, 3 piece design lever operated flanged end ball valve,body test pressure-440 psi,thread type-bsp female,body-ss, length f to f=175 mm, make-universal,shreeram engineers ,zoloto,aira, 40amp double pole rcbo,voltage-230v ac,sensitivity-30ma,make-havells,abb, 3 phase 30 h.p automatic star-delta starter with short circuit protection ,relay range:28-40 a , model-ihhdsdxc,contactor rating: 50 a,full load line current: 43.50 a,full load phase current: 25.12 a,tp mcb rating (a): 100 a make -havells, ac control relay, model-ca2kn31m7,3 no 1nc,coil voltage-220 v ac,make-schneider, ac control relay, model-ca2kn31m7,3 no 1nc,coil voltage-110 v dc,make-schneider, dc
Tender For a.m.c. of dc panel, power house panel, relay and avr in season 2025-26 - amc of dc panel, power house panel, relay and avr in season 2025-26, safety relays devices (english electronic make) for 1500kw alternator main panel (one jyoti & one kirloskar make), automatic voltage regulator having two mode each for 1500 kw alternator (two jyoti & two kirloskar make)