Web Analytics Made Easy - StatCounter

Evaluation Board Tenders

Get complete information related to latest Evaluation Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Evaluation Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Evaluation Board Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45741797 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of spares components to earth leakage detector of anuvidyuth make. the set consists: 1. meter module (main card, insulation tester and panel meter), 2. channel module (channel card fittedwith accessories), 3. main module for add-on units, 4. channel card, 5. mains cards, 6. cable cards, 7. mother board, 8. panel meters, 9. transformer xr-273-3, 10. transformer xr-243-n1, 11. transformer xr-355, 12. terminal strips channel/mains, 13. display card, 14. test leads redx2+green, 15. frc connector for meter reading, 16. relay 4 change over, 17. multi turn pot 20k (mt), 18. reset switch mpu-2, 19. dc buzzer, 20. rotary switch, 21. euro9 connector 32 pin, 22. euro connector 48 pin and 23. 1m potentio meter for main module. firms offer: make/model: anu vidyut [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45735436 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply & installation of evaluation board - imc card of abp002 frauscher msdac system. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45730598 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For churchgate-jogeshwari section : replacement of suburban train indicators with ip based led indicators of non abss stations on age cum condition basis & provision of all in one video display units (avd) and mini video display units (mvd) for fobs, entry-exit, booking & circulating areas, with 2 years camc.

Central Government/Public Sector

CTN :45730601 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For ram mandir-virar section : replacement of suburban train indicators with ip based led indicators of non abss stations on age cum condition basis & provision of all in one video display units (avd) and mini video display units (mvd) for fobs, entry-exit, booking & circulating areas, with 2 years camc.

Central Government/Public Sector

CTN :45704737 Due date: 17 Jul, 202617 Jul, 2026 NA
Tender For jetson orin nano evaluation board

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

State Government

CTN :45737520 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply and configuration of digital boards (75-inch interactive flat panel display units with accessories) for various dav schools of tggenco

CTN :45737546 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of in-coach display for passenger information system (pis) in coach set units, fortrain set coaches as per icf specification no. icf/elec/171 rev-0.. [ warranty period: 30 months after the date of delivery ] ]

CTN :45712200 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of required materials & spare for rectification in pac units at haldia lpg import terminal - refrigerant gas r-407c, drier, filter, r410a, dml 305, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, nitrogen cylinder, 02 use, for gas charging, da use, for gas charging, multiple leakage rectification in pac outdoor units along with brazing and transportation of cylinders, display, small, icom, 180633g3r0 for air conditioning machine, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810
 Loading, Please wait...

Connect us via What's Up