Web Analytics Made Easy - StatCounter

Excavation Repair Tenders

Get complete information related to latest Excavation Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Excavation Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Excavation Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

CTN :45733130 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For auction sale of others - u/s scrap abandoned quarter block no 71 (a-h) 8 unit type ¿i not fit for rly use. bricks 141109.00 nos approx, brick bats- 166.00 cum approx , u/s sariya, angle, xpm gate, window , fencing gate and gi pipe approx 3034 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 10 kg, u/s wooden door frame and panel/shutters approx 230 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208

CTN :45733131 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For auction sale of others - u/s scrap abandoned quarter block no 70 (a-l) 12 unit type ¿i not fit for rly use. bricks 214850.00 nos approx, brick bats- 252.50 cum approx , u/s sariya, angle, xpm gate, window ,fencing gate and gi pipe approx 3886 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 15 kg, u/s wooden door frame and panel/shutters approx 190 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

State Government

CTN :45710161 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For mandi block: israna panchayat: mandi dist.: panipat annual maintenance work for water supply - hire charges of jcb with fuel and driver for excavation, repair of pipe line including excavation bailing out water and refilling 4` i`d4` i`d pipe line

State Government

CTN :45701617 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For auction for the removal of all the debris of room-1 (one) of syntex, gokalpura primary school, ta. jotana, g. mehsana at their own expense and leveling the site to ground level

State Government

CTN :45710156 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For dhandlah block: beri panchayat: dhandlan dist.: jhajjar annual maintenance work for water supply - hire charges of jcb with fuel and driver for excavation, repair of pipe line including excavation bailing out water & refilling etc.

State Government

CTN :45688327 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For auction for the demolition of a total of two (2) dilapidated rooms in shri theravada primary school and the disposal of its debris from the site and leveling the land

CTN :45410518 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For bid to ras supply of electrical item c c - bore bent to shape as required at site , supply and fixing of sub main wiring with three core 1.5 sqmm multi stranded copper conductor pvc insulated unsheathed frls cable 1100 volts grade , supply and fixing of solar street light fitting 12 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and fixing of solar street light fitting 16 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and fixing of solar street light fitting 20 watt having high efficiency mono crystalline solar pv module, lithium ferro phosphate battery with in-built bms technology, high efficacy led , supply and errection in replacement of steel tubular swaged pole 8.5 m long type 410-sp-22 complete with cl base plate , m and l for pcc 1-3-6 type c2 using 40mm graded aggregate crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified and directed. , m and l for plain cement concrete 1-2-4 type b1 using 20mm graded stone aggregate , supply of paint and painting of steel pole swan neck type or straight type up to 9 mtr height with two coat of aluminium paint after scratching out old paint , supply, erect and commissioning of high galvanized mast light of height 15 mtr, suitable for 6 to 9 lantern symmetrically fitted along with their control gear , m and l for boring of horizontal hole under road, pavement, hardstanding suitable for passing through upto 50mm bore complete all specified and directed. , replacement of unserviceable wire by cable from junction box to light fitting fixed on pole on existing pvc conduit by pvc insulated unsheathed copper conductor frls of 1.5 sqmm three core. , supply of laying and digging excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc , returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed , supply of digging and laying removal of excavated material by surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point , supply and laying sand in trenches for protection of cable, sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers complete all as specified and as directed , supply and lay fly ash bricks best quality, laid in trenches, perpendicular to ug cable for cable protection complete all as specified and directed , laying only old bricks obtained from item no 13 perpandicular to ug cable for cable protection complete all as specified and directed. //bid details 2 / 35
 Loading, Please wait...

Connect us via What's Up