Get complete information related to latest Excavation Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Excavation Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Excavation Repair Tenders.
Tender For providing and fixing of 1 ferrule connection with mt, ft, clamp, cpvc pipe , elbows, couplers, tees, cement solvent, manual labour excavation earth work and restoration of paver block complete in all repsect
Tender For tikkar block: morni panchayat: tikkar dist.: panchkula annual maintenance work for water supply - na gi pipes providing and fixing g.i. pipes complete with g.i. fittings including trenching up to 0.30m to 1.00m depth and refilling etc., na water supply, sewerage and drainage works providing and fixing g.i. union in existing g.i. pipe line,cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall.
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For inviting rates of different items for construction of diffrent type of work as per demand on cm help line or ward parsad or public - supply of handpump material 2026-27, excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead up to 1000 m as per section-300 of the specifications.item no nvi-3.12, construction of embankment/sub-grade/earthen shoulders with material obtained from other sources, as per provisions of section 305 of the specifications, with approved materials/soil confirming to requirements given in table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in table 301 2 of the specifications complete.item no nvi-3.12, construction of granular sub-base, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method at omc and compacting with vibratory roller of 80-100 kn static weight to achieve the desired density, including all lifts and lead complete in all respect as per section-400 of the specifications.by mix in place method item no nvi -4.1.1.1, construction of dry lean cement concrete sub- base over a prepared sub-grade with coarse and fine aggregate conforming to is: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of the specifications, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per section 601 of specifications.item no nvi- 6.1.1, providing and laying cement concrete grade m-20 with 20 mm graded crushed stone aggregate, mixing shall be in mechanical mixer, laying with paver compacting by use of pin, plate / screed vibrators including form work by strong steel girders fixed by spikes, separation membrane 125 micron thick, including cutting of joints @ 4 to 5 m interval and filling it with hot applied bituminous sealant (without dowel bars) (max. thickness 20 cm).item no nvi-6.4, construction of dowel jointed, plain cement concrete pavement in m-30 grade concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to is:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor spreading the concrete by shovels, rakes compacted using needle, screed and plate vibrator and finished in a continuous operation including provision of contraction, expansion, and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar, tie rod admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per irc:15 and as per section-602 of the specifications complete excluding cost of steel in dowel bar and tie rod etc.item no nvi-6.2.1, earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom,dressing of sides,disposal of excavated earth including of all lift and lead upto 50m.disposed earth to be levelled and neatly dressed.all kinds of soil item no nii 2.6.1, demolishing cement concrete manually/by mechanical means including disposal of material with in 50 meters lead as per direction of engineer-in-charge.1:3:6 or richer mixitem no nii
Tender For procurement of leakage materials arresting of leakages and in division no.44, 45, 46,47,62,63 and 64 under annual maintenance for the year 2026-27 - 150 mm dia , 150 mm dia 15 mm thick , 160 mm dia , 200 mm dia , 200 mm dia 15 mm thick , 200 mm dia hdpe , 315 mm dia hdpe , 350 mm dia m.s , arresting of leakages at various locations in ward no. 44,45,46,47 &48 including earthwork excavation and arresting of leakages with required materials and red rock cement, portland cement, caulking, necessary apparatus leakage arresting and refilling of the excavated earth includind cost and conveyance of all tools materials and labour charges etc., complete. (a) 160 mm dia hdpe , cost of m.s flanges including cost of bolts, nuts, rubber packing etc., complete and flange thickness conforming to is:7322-1985 and flange dimensions conforming to is:1538-1993 excluding cost of ms specials including cost and conveyance to site etc., complete. (a) 100 mm dia 15 mm thick , manufacture, supply and delivery of di d/f gate valves (soft seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade ggg-40/ sg- 400/15 or ggg-50/sg-500/7 or equivalent grade as per i.s.3896-part2-1985 and subsequent revisions, wedge fully rubber lined with epdm food grade quality and seals of nbr and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per bs5163-89/is14846-2000/din 3202 f 4. all the valves should be with electrostatic powder coating both inside and outside pocket less body passage. drilled as per requirement of the dept. (a) 100 mm dia , manufacture, supply, & delivery of hdpe fittings conforming to is 4984 - 1995 including transportation to anywhere in t.g. excluding taxes. pipe end long neck (a) 110 mm dia , manufacture, supply,& delivery of high density polyethylene pipes (pe-100 grade) for water supply conforming to is 4984-2016 including transportation to any where in t.g, but excluding gst and specials etc.,complete(supply upto 90 mm dia in coil & above 90 mm dia straight length in 6 metres.) 8 kg (a) 110 mm dia hdpe , supply and delivery of 53 grade opc cement bags including all charges etc., complete as per the directions of the departmet officer in charge. , supply and delivery of frc cement supply 5 kg bag including all charges etc., as per the directions of the departmet officer in charge complete. , supply and delivery of nuts and bolts including all charges etc., complete.as directed by the deparment officer in charge. , supply and delivery of packing rope including all charges as per the directions of the departmet officer in charge. , supply and delivery of rubber sheet including all charges etc., as per the directions of the departmet officer in charge complete. , supply, fabrication and fixing in position of ms for windows and grills including cost and conveyance of all material and all labour chages for fabricating, fixing including cost of welding rods, power charges, xcluding cost of fixing in positio etc complete.
Tender For corrigendum : excavation and transportation of earth for capacity enhancement of garai river from km. 12.000 to km. 13.000 in chandauli district
Tender For corrigendum : excavation and transportation of earth for capacity enhancement of garai river from km. 11.000 to km. 12.000 in chandauli district
Tender For corrigendum : excavation and transportation of earth for capacity enhancement of garai river from km. 10.000 to km. 11.000 in chandauli district