Get complete information related to latest Exchange Earthing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Exchange Earthing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Exchange Earthing Tenders.
Tender For supplying electrical materials and repair maintenance services at. grampanchayat chimbali. - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1-3-3, supplying and e
Tender For pre-mansoon repair and maintenance work of mechanical dam including oiling,greasing, servicing and wire rope compounding work of radial gates, lbmc intake gate machineries for the year 2026-27
Tender For eor to civil works at distt. north west b1 and b2 office and sarvodaya vidyalaya fu block pitampura delhi. sch id 1411008 eor id 20261092 sh repair and renovation of dde district office sections toilets and corridors providing and fixing flush door providing and fixing wire m
Tender For repair/replacement to interlocking tiles, chequered tiles, smart periodicals on compound wall, concertina coil, barbed wire and connected item etc in otm accn in the area of age b/r-i under ge (west) delhi cantt-10
Tender For repair to barbed wire, chain link, concertina coil, angle iron and other connecting repair to fencing at tech area under age b/r ii at afs chabua under (ge) af chabua
Tender For corrigendum : repair to sunken flooring, plumbing with connected items to otm accn in aor of age b/r-ii of ge (east) ferozepur cantt - demolition of un-reinforced cement concrete in any position, complete all as specified and directed., m&l for cement concrete (1:5:10) type e-2 using 40 mm graded stone aggregate as in filling in sunkan slab or as in sub base, mass concrete, complete all as specified and directed., m&l for 15 mm thick rendering over concrete surface of sunken floor in cm 1:3 on wall as well as sunken floor finished even and smooth without using extra cement using wpc complete all as specified and directed.(wpc measured and paid separetely), m&l for water proofing treatment to rcc sunken floor including wall comprising with the following course of treatment/ specifications form bottom to top:-(a) applying evenly a tack coat of industrial bitumen 85/25 @ 1.6 kg per sqm over a coat of bitumen primer @ 0.40 ltr per sqm including preparation of roof surfaces complete all as specified and as directed.(b) app based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.note: (i) laying of app based membranes shall be done by torch on method or as per manufacturers instructions.(ii) a minimum overlap shall be not to be less than 150mm of polymeric membranes and sealed all overlaps and joints as manufacturers instructions.(iii) all ci/pvc traps in sunken slabs to be enclosed with pcc 1:1.5:3(min 15 cm) all round., supply only integral water proofing compound, complete all as specified and directed., taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished fair and even including wpc,preparation of new plastered or unplastered surfaces and applying two coats of cement based paint over a coat of chalk white primer on walls complete all as specified and directed. (wpc measured and paid separately), m&l for preparing old surfaces plastered or unplastered of walls, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coats of cement based paint complete all as specified and directed., m&l for rendering 15 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished fair and smooth without using extra cement complete all as specified including preparation of new surfaces of wall and applying two coats of oil bound distemper on walls including corneces, pillars etc complete all as specified & directed., m&l for preparation of old decorated surface of wall and applying one coat of oil emulsion distemper, complete all as specified and directed., m&l for rendering 5 mm thick on ceiling surfaces in cement mortar (1:3) finished even & smooth without using extra cement including preparation of new plastered or unplastered surfaces and applying two coats of white wash on ceilings, complete all as specified and directed., m&l for preparing old surfaces plastered or unplastered of ceiling, cornices, pillars etc including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime wash (white washing), complete all as specified and directed., resecuring or eashing & adjusting, without taking down of shutters of any description of exc. 1 sqm but n.exc. 2 sqm each complete all as specified & directed., taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 square metre each including cut
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply of femoral adjustable loop , interference screw , suture disc or plain endobutton , fiber wire no 2 , shaver blade , all inside meniscus repair set of all angles , inside out meniscus repair needles with preloaded suture , fiber tape , all suture anchors for bankart 1.8 or 2.3mm single, double, triple loaded , peek anchors for rotator cuff 5 or 5.5mm single, double, triple loaded , push lock or knotless anchors for lateral row , arthroscopic high speed burr , arthroscopic cannula 5.5, 6.5, 8 mm , radiofrequency ablator , disposable antegrade passer or scorpion