Get complete information related to latest Exchangers Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Exchangers Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Exchangers Tenders.
Tender For corrigendum : supply of quench cum venturi cum packed bed column cum bop as per annexure_3_ price bid format cl.1.1a_1.1b_1.1c , gas to gas heat exchanger as per annexure_3_ price bid format cl.1.1 d , sintered metallic filter system as per annexure_3_ price bid format cl.1.1 e , mercury guard bed with catalyst as per annexure_3_ price bid format cl.1.1 f , special tools _tackles as per annexure_3_ price bid format cl.1.2 , consumables, lubricants, commissioning spares as per annexure_3_ price bid format cl.1.3 , spares, special maintenance tools as per annexure_3_ price bid format cl.1.4 , mandatory spares as per annexure_3_ price bid format cl.1.5 , supervision services _per diem rates per service engineer _as per annexure_3_ price bid format cl.2.1 , supervision services _travel expenses from vendor works to project site and back _as per annexure_3_ price bid format cl.2.2
Tender For corrigendum : rate contract for 02 years( extendable) for purchase of various types of consumables for department of aneaesthesiology, pgims, rohtak- heat & moisture exchange filters (hmef): hepa bacterial and viral fi with hme properties offering optimum hydrophobic filtration performance. gas sampl port, for end tidal co2 monitoring. recommended tidal volume range 150-1200ml.ev pleated filter medium to allow maximum filtration efficiency with minimal resistance flow. low dead space, not more than 45-55 ml. single use, sterile ece/usfda/iso/ , heat&moisture exchangers (hme) filter for pediatric us , recommended tidal volume <600ml.low weight. low dead space. suitable for b ventilated and spontaneously breathing patients. low resistance to flow. corrugated pa medium with high efficiency to recover about 75% of the energy and moisture. single sterile. ece/usfda/iso , heat & moisture exchangers (hme) for spontaneous breathing in tracheostomized patients. suction port to allows access to suct , catheter. clear housing to allow visualization of contamination. integrated oxygen port allow delivery of supplemental oxygen. recommended tidal volume range from 1000ml.compact and lightweight. corrugated paper medium device can be used fo maximum period of 24 hours. single use sterile. minimum resistance anti occlus mechanism. ece/usfda/iso , epidural set. a set containing tuohy's epidural needle minimum length 80m 16g, 17g and 18g, and corresponding gauge epidural catheter with closed tip and th lateral eye, length 90-100 cm and flat filters 0.2 micrometer hydrophilic two way, fill area approx 4.91 cm², priming volume 0.75 ml all connections should be of luer lock ty lor(loss of resistance) syringe, presterilized. ece marked/usfda approved , combined spinal epidural set. containing 18 g touhy epidural needle minimum 80 mm length. pencil point, spinal needle with twist lock system, marking tuohy's needle hub and depth marking on tuohy's needle hub containing correspond clear catheter with connection, closed end and 3 lateral eye of approx. length 90-100 with epidural filter 0.2 micrometer hydrophilic two way, epidural sponge and lor (loss resistance) syringe. ece marked/usfda approved - , needle for spinal anaesthesia, quincke type, same colour coding the hub and stylet, presterilized. usfda and europen ce approved- , (a) 23 g, 90mm length od approx 0.64 mm, , (b) 24g,90mm length od approx 0.5mm with/without introducer , (c) 25g, 90 mm , (d) 26g, 90 mm , (e) 27g, 90mm , paed. spinal needle without introducer, colour coded length 50mm, g, od 0.5 mm, presterilized. usfda and europen ce approved , cuff manometer: allows controlled initial cuff inflation. intermittent press monitoring facility. instant visual confirmation of intra-cuff pressure. simple operation pressure adjustment without need for disconnection or introduction of syringe into syst solid green zone indicates usual cuff pressure range for tracheal & tracheosto tubes.connecting tube is supplied with the gauge for convenient positioning. portable ga and clips easily into pocket. , face mask- clear, reusable, pvc material, transparent for good visibil adjustable cushion for better comfort. , sizes:- , a) 0, , b) 1, , c) 2, , d) 3,0) 4,1) 5- , anatomical facemask made up of antistatic inflating pad, malleable, anatom. chaned to give precise seal and fit comfortably, sizes 1.2.3.4 , disposable lma with preformed curve 90 degree like ilma with airwa tube with standard connectors for anaesthesia circuit. us fda approved. sizes 1, 1.5,2, 2.5,3,4,5 , resuable pressure infusion bag for administration of fluid to patient unde pressure, compatible with 500 ml fluid bags, flexible, stury, pvc tubing and manometer stop cock and hand pump, latex free , clear pressure- monitoring lines, which can withstand pressure up to 500 psi with minimal damping, non kinkable, pre-sterilized, disposable, id/ed1/2 mm. length 100 cm, 150cm & 200 cm. low dead space but pe may be optional
Tender For corrigendum : supply of rhm26r8024 welded plate type heat exchanger (phe) , rhm26r8024 mandatory spares for plate type heat exchanger (106-e-01-c) , rhm26r8024
Tender For providing of custom bid for services - 200153563 contract for running maint, shutdown and overhauling of heat exchangers, strainers, bellows, h2 cylinder shifting, oil cleaning etc in stg i 200mw units sstps
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - repair & maintenance of columns, vessels, heat exchangers, air fin coolers, reactors, furnace, pipings & other miscellaneous hot and cold jobs during unplanned/ short and emergency shutdowns at barauni refinery.
Tender For corrigendum : supply of 9040m26d80 heat exchangers tube bundle item 10 of rfq sap code 2934855728 , item 20 of rfq sap code 2959170022 , item 30 of rfq sap code 2934360028 , item 40 of rfq sap code 2921480014 , item 50 of rfq sap code 2934370028 , item 60 of rfq sap code 2959010028 , item 70 of rfq sap code 2999991588 , item 80 of rfq sap code 2999999968 , item 90 of rfq sap code 2999999968 , item 100 of rfq sap code 2999999968 , item 110 of rfq sap code 2999999964 , item 120 of rfq sap code 2999992824 , item 130 of rfq sap code 2999993204 , item 140 of rfq sap code 2999100234
Tender For work of cleaning of plate type heat exchangers of acw/ccw and stg lube oil system at ccpp ii on as & when required basis at 370mw, gbps, utran
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rolling of tubes in shutdown heat exchangers at raps-4.
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For bid to ras providing of custom bid for services - mobilization and demobilization,custom bid for services - rvi of heat exchangers,custom bid for services - fsect of heat exchangers,custom bid for services - ect of heat exchangers,custom bid for services - rfet of heat exchangers,custom bid for services - iris of heat exchangers,custom bid for services - rvi of equipment