Get complete information related to latest Fan And Blower Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan And Blower Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan And Blower Tenders.
Tender For auction sale of automotive fabric scrap,rubber scrap(pcb category),scrap battery (pcb category),scrap plastics(pcb category ),e-waste(pcb category),scrap windshield (glass scrap),dismantled engine scrap tractor,scrap compressors,scrap alternators and starters,radiator and condenser scrap,scrap motors- fan motor, blower motor and wiper motors,seat scrap,cargo boxes,defaced cng cylinder,wiring harness,catalytic convertors lot 1(pcb /moef bidders will only be able to bid this lot),catalytic convertors lot 2(pcb /moef bidders will only be able to bid this lot),catalytic convertors lot3 (wire mesh)(pcb bidders only be able to bid this lot)
Tender For auction sale of automotive fabric scrap,rubber scrap (pcb category),scrap doors and body panel ( with glass and plastic),scrap plastics(pcb category ),scrap windshield (glass scrap),dismantled engine scrap tractor,defaced engine scrap (2w),defaced engine scrap (4w),scrap compressors,scrap alternators and starters,radiator and condenser scrap,scrap motors- fan motor, blower motor and wiper motors,seat scrap,mix steel scrap 4w ( retail),cargo boxes,defaced cng cylinder,wiring harness
Tender For supply of gen set spares - carburator assy , starter switch , element air filter , fan belt , blowerfan assy , cell crank shaft , filter fuel , fuel filter body , transparent glass , counter shaft , c channel , connecting rod , meter electronic , counter gear , gasket set , gear oil pump
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blowerand gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For supply of mpcb for ventilation fan unit (blower motor unit) 1 & 2, thermal release range(rated current): 2 . 5 - 4 a, class-10,breaking capacity : 50 ka, 3 pole, rated voltage: 415 v ac, 1 no+1 nc auxiliary contact block as per rdsocommon bill of material letter no. el/7.1.108/mssbc dt.17.09.21 ,annexure column no.1,sl.no.37,conforming to column no 7. make: as per rdso common bill of material(bom) dated 17/9/21 i.e.abb catalogue no.ms 116-4/legrand/schneider catalogue no. gv2me08+gvae11/l&t catalogue no.st418960000/siemens catalogu eno.3rv2011-1ea10+3rv2901-1e/eaton. [ warranty period: 30 months afterthe date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of air conditioner e e - gas check-up pressure testing , full gas charging , nitrogen pressure testing , internal leakage repair , water leakage repair , drain pipe replacement , insulation refixing , copper condenser coil split , copper condenser coil window , copper cooling coil split , cooling coil repair , new compressor , replacement compressor old , pcb repair inverter , pcb repair non-inverter , pcb replacement universal with remote , capacitor , contactor , sensor transfomer fuse replacement , fan motor , blower motor , motor bearing chenge noise adustment , swing flap motor blade replacement , new ac installation , ac uninstallation , outdoor indoor reinstallation , copper piping with insulation and wire , foam jet deep ac service , lite ac service , anti-rust spray external cleaning , visiting or inspection charge
Tender For bid to ras supply of supply of refrigerant r22 gas , supply of refrigerant r410a , supply of refrigerant r32 , supply of refrigerant copper pipe 1by4 inch , supply of refrigerant copper pipe 1by2 inch , supply of refrigerant copper pipe 5by8 inch , supply of refrigerant copper pipe 3by8 inch , supply of flare nuts of different size , supply of refrigerant pipe insulation of different sizes , supply of pvc self adhesive white monsoon tape 48mm - minimum 18m roll , supply of 440v capacitors in the range of 35-55mfd , supply of anchor fastener m8x50mm , supply of teflon tape 12mm minimum 10m roll , supply of copper brazing rod 3. 2mm thick minimum 300mm long , supply of butane gas 225gm bottle , supply of ac drain flexible pipe , supply of air conditioner fan blade , supply of air conditioner 1. 5t or 2t pcb for noninverter type , supply of air conditioner 1. 5t or 2t pcb for inverter type. , repairining of air conditioner coil leakage , supply of outdoor fan safety grill or cover , supply of stablizer for ac , supply of indoor unit fan or blower , supply of ac remote make voltas , hitachi , midea , carrier etc , repairing of ceiling fan motor , repairing of domestic exhaust fan , repairing of heavy duty exhaust fan , rewinding of stator of 7. 5 hp motor , repairing of electric water geyser ) /bid number: gem/2026/b/7143336 * /dated: 27-02-2026 & & / bid document1 / 35