Get complete information related to latest Fan Casing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Casing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Casing Tenders.
Tender For bid to ras supply of fancasing cover assy to drg. no. 24023040017, var. 01, rev. 04. , fancasing cover plate to drg. no. 24023440002. var. 01, rev. 04. , air guide assy / fancasing cover to drg. no. 34027440099 var 01, rev. 02.
Tender For rate contract of miscellaneous item for financial year 2026-27 at grampanchayat ghot tah. chamorshi- 9 watt led bulb, 12 watt led bulb, 18 watt led bulb, 20 watt led bulb, 23 watt led bulb, 30 watt led bulb, 50 watt led bulb, 12 watt battery backup bulb, 20 watt led tube light, 20 watt led street light, 24 watt led street light, 30 watt led street light, 36 watt led street light, 40 watt led street light, 45 watt led street light, street light clamp,angle and nut-bolt, 50 watt led flood light, 100 watt led flood light, 150 watt led flood light, 200 watt led flood light, holder heavy 6amp, holder 6amp, 1/18 wire bundle , 2.5 mm service wire bundle , 1 mm multi wire bundle, 1.5 mm multi wire bundle, 2 mm multi wire bundle, 4 mm multi wire bundle, 4 mm service wire bundle, 6 way moduler board , 6amp socket, 16 amp socket, 6amp switch, 16 amp switch, 3 pin top 6amp, 3 pin top 16amp, meter peti, wooden board, 16 amp main switch, 32 amp main switch, 16 amp mcb, 32 amp mcb, power plug, dp switch, celing fan , wall fan , stand fan, casing patti , cooler 4 feet , cooler 6 feet , cooler, insulation tep , 1 hp submercible pump (ac), 3 hp submercible pump (ac), 5 hp submercible pump (ac), 7.5 hp submercible pump (ac), 1 hp mono block pump , dc grundfose motor 2.5-2, helical shift 2.5-2, hydrolic kit 2.5-2, magnetic motor 2.5-2 , trust bearing 2.5-2, carbon platet bearing, hydrolic cylender, n.r.v, sensor cable , 1 hp starter , 5 hp starter , 1 hp submercible pump (dc), 3 hp submercible pump+motor +controller (dc), 5 hp submercible pump+motor +controller (dc), 7.5 hp submercible pump+motor +controller (dc), 2.5 mm submercible cable , 100 watt solar panle , 150 watt solar panle , 335 watt solar panle , 545 watt solar panle , 4 mm dc cable , flot (sensor), cotroler (dc), 8 mm rope, 1kva inverter + battery 150ah, 2kva inverter + battery 150ah x 2, 3kva inverter + battery 150ah x 2, 1kva inverter + battery 150ah solar panle home light system, 3kva inverter + battery 150ah solar panle home light system, 5kva inverter + battery 150ah solar panle home light system, 1kva roof top (solar panle +structure), 3kva roof top (solar panle +structure), 5kva roof top (solar panle +structure), solar kandil, 12 watt led solar street light , 15 watt led solar street light, 12 watt led solar street light with pole and accessories complet, 15 watt led solar street light with pole and accessories complet, 7 mtr solar highmast (octagonal pole, 30 watt solar street light - 5, 30 amp lithium battery - 5, 100 watt solar panle - 5) , 9 mtr solar highmast (octagonal pole ,50 watt led street light - 4, 30 amp lithium battery - 4, 100 watt solar panle - 4), 9 mtr highmast light (ac) (octagonal pole, 150 watt flood light - 5 etc…..), 12 mtr highmast light (ac) (octagonal pole, 200 watt flood light - 5 etc…..), water filter 12 lph (ro machine ), water filter 15 lph (ro machine ), water filter 20 lph (ro machine ), water filter 25 lph (ro machine ), water filter 50 lph (ro machine ), water filter 500 lph (ro machine ), water filter 1000 lph (ro machine ), seadimate candel 25 lph /50 lph, p.p candel 25 lph/50 lph, carbon candle 25 lph / 50 lph, membran ro 100 gpd, membran ro 150 gpd, ro booster pump 150 gpd, ro s.v, ro booster pump 100 gpd, ro smps, water cooler 20+20 , water cooler 20+40, water cooler 80+40, refrizrator 180 lph , 32" led tv (smart android), 43" led tv (smart android), ahuja sound system (amply 120 watt-1, unit-60 watt-2, bhonge -2, mick-2 mick stand -2) , ahuja sound system (amply 225 watt-1, unit-60 watt-2, bhonge -2, mick-2 mick stand -2) , speaker box , c.c.t.v camera setup (4 cha dvr ), c.c.t.v camera setup (8 cha dvr), all in one sound system , fogging machine , 12vo/100ah battery , 12vo/150ah battery , 850 nxg solar inverter, 12vo/1050 watt inverter, 24vo/2300 watt inverter, solar panle structure, 12 way surface box, 8 way surface box, 6 way surface box, battery water 1 ltr , mobile starter , mini ac & dc home light system (light - 3, led light s
Tender For corrigendum : tender for supply of spares for main mechanical ventilation fan - pv 200fan pulley(p no 08507 06007) , pv 200 motor pulley (p no 8507 06903) , pv200 mv fan complete rotor assy (p no 8507 06300c) , pv 200mv fan complete rotor assy (pno 8507 06300) , pv 200 plummer block assy (fixed or float) (p no 8507 06500 ) , pv 200 fancasing & inlet cone (p no 8507 06000) , pv 160 mv fan pulley (8506 06007) , pv 160 mv motor pulley (8506 10903) , pv 160 fancasing with inlet ring (p no 8506 10100) , pv160 mv fan coplete rotor assy (p no 8506 10300c ) , pv 160 fan rotor assy (p no 8506 10300) , pv 160 plummer block assy (fixed or float) (p no 8506 10500) , pv160 mv fan shaft assy (p no 8506 10001) , vf-3000 rotor assy ( p no 8508 01400) , vf-3000 coupling assy (p no 8508 09160) , vf-3000 mv fan shaft pulley , ci grade 20 ( p no 8508 01801) , vf-2500 fan rotor or fan shaft assy ( p no 8510 01500) , vf-2500 fan side plummer block assy (p no 8510 01600b) , vf-2500 fan pulley ( p no 8510 01805) , vf-2500 motor pulley ( p no 8510 09151)
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For repair of bag house equipment in crmp- 1) cage repair( bending minor welding & painting), 2) cleaning and fixing of bags( opening the chamber, removing the venturies, taking out bags cleaning with and refixing) once in year, 3) cleaning of dust collecting hopper of bag house, 4) repair of dust hopper and its doors, 5) bag house screw conveyor body repair, 6) bag house screw conveyor hanger bearing with shaft changing, 7) bag house screw conveyor end bearing changing, 8) bag house screw conveyor coupling repairs, 9) bag house screw conveyor changing, 10) en masse conveyor drive sprocket changing, 11) en masse conveyor tail sprocket changing., 12) en masse conveyor drive chain fixing, 13) en masse conveyor links changing, 14) en masse conveyor drive unit coupling repair, 15) en masse conveyor drive chain rejointing in snap, 16) maintenance of rotary air locks (twice in a year), 17) bucket elevator belt rejointing in case of snap, 18) bucket elevator drive pulley changing, 19) bucket elevator boot pulley changing, 20) bucket elevator fallen buckets fixin, 21) pulse jet solenoid valves repair and maintenance, 22) drier maintenance in compressor house (4 driers), 23) maintenance of compressed air pipe line, 24) id fancasing removal and fixing back to faciltate for fan changing, 25) id fancasing cutting and fixing back during bearing changing, 26) id fancasing changing, 27) id fancasing repair work, 28) id fan suction duct patch work, 29) id fan delivery duct patch work, 30) to make arrangement for chimney cleaning on id fan delivery duct near chimney and duct opening and closing there.., 31) dust hopper gate replacement, 32) dust hopper vibrofeeder replacement, 33) dust hopper body repair patch work, 34) flexible hose to pulse jet replacement, 35) pulsing pipe changing, 36) pulsing pipe repair, 37) cyclone patch work, 38) flue gas duct leaks arresting patch works.