Get complete information related to latest Fan Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Fitting Tenders.
Tender For supply of pendant holder , led tube light 4 inch 20 watts , led bulb 5 watts , led bulb 9 watts , 6 amps switch , 16 amps switch , 6 amps 5 pin socket , 16 amps combined switch with socket and box , 16 amps 5 pin socket , pvc casing capping 3 by 4 inch , pvc casing capping 1 inch , wall mounting fan copper coil , condenser 2.25 mfd 415 volts , spmcb 16a l and t , tpmcb 63a l and t , exhaust fan 12 inch copper coil , ceiling fan 48 inch copper coil , sub energy meter digital , led street light 50 watt , led street light 30 watt , rewinding of 3 phase deep boring submersible pump 6 and 4 hp , pvc wire 4.0 sq mm copper , pvc wire 2.5 sq mm copper , pvc wire 1.5 sq mm copper , pvc wire 1.0 sq mm copper , pvc wire 0.75 sq mm copper , rewinding of 3 phase submersible pump open well 10 hp , exhaust fan 18 inch copper coil , emergency led tubelight 20 watt , combination pliers , wire stripping pliers , neon tester 500v , hand gloves 11000v electric shock proof , insulation tape pvc , aluminium cable 16 sq mm 3 core , water level controller llc-101 3 phase , spmcb 6a l andt
Tender For repair maintenance of ceiling fans exhaust fan air circulators wall fans flame proof fans safety check of ceiling fans etc at ins dega ins eksila dega vihar abe park nad cqae cnai dsc dad arogya complex inhs kalyani ncb svn colony
Tender For repair / maint of ceiling fan, exhaust fan, wall mounted fans and other appliances along with connected repair works in smq, omq, various messes and otm accn at af-i under ge (af) jamnagar no.2
Tender For repair / replacement of internal unserviceable point wiring / fitting / fixture and connected accessories work in karam singh enclave and bana singh enclave under age e&m-iv of ge (south) bathinda at bathinda mil stn - taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, bell pushes, ceiling roses, pendants, regulators, sockets, light fitting, call bells etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing colour complete all as specified and directed., material and labour for concealed one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic pvc conduit of 20 mm dia in medium grade complete with and including all pvc conduit accessories concealed into wall by cutting of chases in wall complete and including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator and brass screws, cup washers etc complete, making good the distributed surfaces completely matched and finished with existing surface including painting of walls etc complete all as specified and directed. , all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on same board point, complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but one 3 pin socket outlet 6 amp on the independent board point with pvc fr-lsh cable size 2.5 sqmm complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one bell point controlled by one bell push on independent board complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but one light point controlled by two way switch complete all as specified and directed., all as per srl item no. 2.00 (here-in-before) but for 15/16 amp socket out let/power point by using 2.5 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 2.5 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, all as per srl item no. 2.00 (here-in-before) but for 15/16 power point (ac & geysers) by using 4.0 sqmm pvc insulated unsheathed copper conductor cable fr-lsh multi strand on independent board including provn of 4.0 sqmm unsheathed, multi stranded copper conductor cable fr-lsh continues as earth wire connected to earth dolly etc complete all as specified and directed, material and labour for one light / fan point controlled by one, one way modular switch 06 amp wiring with 1.5 sq mm nominal cross sectional area, single core, 1100 volt grade, multi-stranded, pvc insulated, unsheathed frls copper conductor cable with and including continuous earth wire of size 1.5 sq mm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, pvc insulated, unsheathed, frlsh copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and in existing rigid non-metallic pvc conduit including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch /fan regulator
Tender For repair maint of various size/make of ceiling fan, wall mounted fan, geyser and replacement of various type e/m fixtures and allied works at nms under age (i) nabagram