Get complete information related to latest Fastening Tape Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fastening Tape Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fastening Tape Tenders.
Tender For supply of x3-mast-17m-02-538-10-0 exhaust silencer with ss joint exhaust p , x3-mast-17m-03-036-01-0 o ring dipstick 2 x 521515 or 21511 , x3-mast-17m-6h-431-09- 000 spnr de 18x19mm , x3-mast-17m-6h-431-07-000 spnr de 14x15mm , x3-mast-17m-6h-431-11-000 spnr de 20x22mm , x2- misc-lorros-03-240-03-0-00 cutting plier type 1121 , x2- misc-lorros-03-240-02-0 hammer ball pane 500 gm with handle , x3-mast-17m-03-240-11-0 nose plier with insulated handle 200mm l , x2-misc-lorros-03-220-17-0 nylon pvc pipe s mtr , x2-misc-lorros-03-915-11-0 battery cable assy positve and negative , x3-mast-17m- 6h-431-08-000 spnr de 16x17mm , x3-mast-17m-6h-431- 06-0-00 spnr de 12x13mm , x2-misc-lorros-03-286-01-0 fuel tank assy with fuel level sensor e , x3-mast-17m-04- 250-01-000 v belt a x 43 raw edge cogged lp 1131 h , x3- mast-17m-34-032-02-000 pre filter element
Tender For corrigendum : supply of 2hp welding blow pipe , nozzle 2 and 3 and 13 and 20 and 30 , oxygen gas cylinder regulator , acetylene gas cylinder regulator , oxygen gas cylinder pipe black , acetylene gas cylinder pipe red , 300g machinist hammer , 600g long lasting hammer , tools water proof nylon tool bag , hy duty 15 ton hydraulic long floor jack for trucks , diesel injector extractor puller
Tender For supply of item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall diameter (mm) /- 2.0 15 max. safe pulling tension lo